{"product_id":"honeywell-cc-tdil01-24v-digital-input-module-0-19a","title":"Honeywell CC-TDIL01 24V Digital Input Module | 0.19A","description":"\u003ch2 style=\"color:#0055A4;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color:#0055A4;\"\u003eCC-TDIL01\u003c\/strong\u003e is a Honeywell Digital Input IOTA (Input Output Terminal Assembly). This 24V DC module captures discrete field signals for Experion PKS. It serves limit switches, push buttons, and proximity sensors.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable width=\"100%\" border=\"0\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd width=\"40%\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd width=\"60%\"\u003eHoneywell\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eProduct Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eCC-TDIL01\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eDigital Input IOTA Module\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e24 VDC (20.4 to 28.8 VDC)\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e16 channels (sink\/source configurable)\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eCurrent Draw\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e0.190 A (190 mA @ 24 VDC)\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eHeat Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e4.220 Watts\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e24 VDC dry contact or 3-wire proximity\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eON State Voltage\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e≥15 VDC\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eOFF State Voltage\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e≤5 VDC\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e4.7 kΩ\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e2 ms (ON to OFF) \/ 1 ms (OFF to ON)\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e1500 Vrms (channel to backplane)\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e-40°F to 185°F (-40°C to +85°C)\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eDIN rail or panel mount\u003c\/td\u003e\n   \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003cp\u003eConnect dry contacts between input terminal and common. For 3-wire proximity sensors, connect +24V, common, and signal. Do not exceed 28.8 VDC on any input channel. Verify field device sinking or sourcing configuration before wiring.\u003c\/p\u003e\n\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThis IOTA module dissipates only 4.22 watts, minimizing cabinet heat load. The 4.7 kΩ input impedance prevents false triggers from leakage current. Channel-to-backplane isolation at 1500 Vrms protects the controller from field surges.\u003c\/p\u003e\n\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e Can I mix sinking and sourcing inputs?\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e Yes. Each channel configures independently as sink or source via terminal wiring.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e What is the minimum ON state voltage?\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e The module guarantees ON state at ≥15 VDC. Between 5V and 15V, the reading is undefined.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e Does this support 12 VDC input signals?\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e No. The CC-TDIL01 requires 24 VDC nominal. Use an interposing relay for 12 VDC field devices.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51886706360452,"sku":"CC-TDIL01","price":238.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-TDIL01.jpg?v=1779628692","url":"https:\/\/www.etowonauto.com\/tk\/products\/honeywell-cc-tdil01-24v-digital-input-module-0-19a","provider":"Etowon Auto","version":"1.0","type":"link"}