{"product_id":"dc-tcf902-honeywell-experion-pks-module","title":"DC-TCF902 Honeywell Experion PKS Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eHoneywell DC-TCF902 51307945-176\u003c\/strong\u003e is a high-density Thermocouple Input and Digital I\/O module engineered for industrial process control. It integrates directly with Honeywell TDC 3000 and Experion PKS Distributed Control Systems (DCS). This module provides direct interfacing for temperature sensors and discrete field devices, ensuring high-accuracy data processing and system reliability in demanding automation environments.\u003c\/p\u003e\n\n\u003ch2\u003eKey Technical Features\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual-Redundant Architecture:\u003c\/strong\u003e Features a dual-redundant processor design to prevent system downtime and ensure continuous process monitoring.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMulti-Sensor Support:\u003c\/strong\u003e Interfaces natively with Thermocouple Types J, K, T, E, R, S, and B with onboard cold-junction compensation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVersatile Protocol Integration:\u003c\/strong\u003e Supports industry-standard communication layers including Modbus, OPC, and Ethernet\/IP.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 15px;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2; text-align: left;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eDC-TCF902\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e51307945-176\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eI\/O Configuration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e16 Digital Inputs \/ 16 Digital Outputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e24 VDC nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e170 x 71 x 140 mm (6.69 x 2.80 x 5.51 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0.68 kg (1.5 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0°C to 50°C (32°F to 122°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation \u0026amp; Field Guide\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Maintain at least 300 mm separation between thermocouple wiring and high-power AC lines to eliminate electrical noise.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Terminate overall cable shields at a single point, preferably at the marshaling panel ground bar.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClearance:\u003c\/strong\u003e Leave 50 mm of free space above and below the module housing inside the enclosure for proper ventilation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Build:\u003c\/strong\u003e Industrial-grade housing withstands continuous thermal stress and harsh environment conditions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCost Efficient:\u003c\/strong\u003e Combines 16 input and 16 output points on a compact footprint to save valuable cabinet and slot space.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLegacy Migration:\u003c\/strong\u003e Enables seamless hardware replacements and hot-swaps between legacy and modern control platforms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can I mix different thermocouple types on adjacent channels?\u003c\/strong\u003e\u003cbr\u003e\nA1: Yes. Channels are individually configurable via software to accept different curves natively without external components.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How fast does the module switch to the backup path during a fault?\u003c\/strong\u003e\u003cbr\u003e\nA2: The dual-redundant system executes a bump-less transfer within milliseconds to prevent control loop interruptions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What happens if a thermocouple wire breaks in the field?\u003c\/strong\u003e\u003cbr\u003e\nA3: The module triggers an open-circuit fault, configured via software to fail safely upscale or downscale based on your plant guidelines.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51050818994308,"sku":"DC-TCF902","price":239.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/DC-TCF902_51307945-176.jpg?v=1779550030","url":"https:\/\/www.etowonauto.com\/tk\/products\/dc-tcf902-honeywell-experion-pks-module","provider":"Etowon Auto","version":"1.0","type":"link"}