{"product_id":"51308353-175-honeywell-16-ch-analog-output","title":"51308353-175 Honeywell | 16 Ch Analog Output","description":"\u003ch2 style=\"color:#0055A4;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color:#0055A4;\"\u003eCC-TAOX11 (51308353-175)\u003c\/strong\u003e is a Honeywell 16-Channel Analog Output Module. It delivers 4-20 mA signals to field actuators, valves, and positioners. This module ensures precise control for Experion PKS.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable width=\"100%\" border=\"0\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd width=\"40%\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd width=\"60%\"\u003eHoneywell\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eProduct Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eCC-TAOX11 \/ 51308353-175\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eAnalog Output Module\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e4-20 mA (sourcing)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e16 channels (isolated)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e15 bits plus sign\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e±0.1% of span (25°C)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eLoad Resistance\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e0 to 750 Ω\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eUpdate Rate\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e10 ms per channel\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e-40°F to 185°F (-40°C to +85°C)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e24 VDC ±10%\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e250 mA (typical)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eOpen circuit \u0026amp; short circuit detection\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003cp\u003eWire each channel using shielded twisted pair cable. Connect the shield to earth ground at the module end only. Do not exceed 750 Ω load resistance per channel. Verify 24 VDC supply polarity before powering the module.\u003c\/p\u003e\n\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThis module drives 16 independent 4-20 mA loops. Onboard diagnostics report open circuits and short circuits to Experion PKS. The CC-TAOX11 operates reliably from -40°F to 185°F, suitable for turbine halls and compressor stations.\u003c\/p\u003e\n\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e Can this module output 0-20 mA?\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e No. The CC-TAOX11 supports 4-20 mA only. 0 mA indicates a loop fault.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e What happens if a channel overloads?\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e The module reports a short circuit diagnostic. Each channel resets automatically after fault removal.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e Is HART protocol supported?\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e No. This module transmits 4-20 mA analog signals only. Use a HART multiplexer for digital communication.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51886704033924,"sku":"51308353-175","price":229.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/51308353-175.jpg?v=1779627530","url":"https:\/\/www.etowonauto.com\/tk\/products\/51308353-175-honeywell-16-ch-analog-output","provider":"Etowon Auto","version":"1.0","type":"link"}