{"product_id":"3hac058424-001-safe-board-irc5-sil2-pld-abb","title":"3HAC058424-001 Safe Board | IRC5 SIL2\/PLd ABB","description":"\u003ch2\u003eGeneral Information\u003c\/h2\u003e\n\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cb\u003eABB DSQC400E 3HAC058424-001\u003c\/b\u003e is a safety circuit board for IRC5 robot controllers. It monitors emergency stop, safety gate, and light curtain circuits, cutting servo enable and brake signals within 10 ms when a safety condition triggers. The board carries PLd (Cat. 3) \/ SIL2 safety certification and weighs approximately 300 g.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;font-weight:bold;\"\u003eProduct ID\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003e3HAC058424-001\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;font-weight:bold;\"\u003eModel\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003eDSQC400E\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;font-weight:bold;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003eSafety Circuit Board (Robot Safety Board)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;font-weight:bold;\"\u003eSystem Compatibility\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003eABB IRC5 (Compact and Single)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;font-weight:bold;\"\u003eSafety Integrity Level\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003ePLd (Cat. 3) \/ SIL2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;font-weight:bold;\"\u003eSafety Inputs\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003e8 dual-channel inputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;font-weight:bold;\"\u003eSafety Outputs\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003e5 relay outputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;font-weight:bold;\"\u003eResponse Time\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003e\u0026lt; 10 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;font-weight:bold;\"\u003eOperating Voltage\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003e24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;font-weight:bold;\"\u003ePower Consumption\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003e10 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;font-weight:bold;\"\u003eInput Signal Voltage\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003e5 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;font-weight:bold;\"\u003eCurrent Rating\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003e1.5 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;font-weight:bold;\"\u003eCommunication Protocol\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003eCAN bus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;font-weight:bold;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003e0°C to +60°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;font-weight:bold;\"\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003e-25°C to +70°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;font-weight:bold;\"\u003eProtection Class\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;font-weight:bold;\"\u003eMTBF\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003e150,000 hours\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;font-weight:bold;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003eApprox. 300 g (0.66 lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;font-weight:bold;\"\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd style=\"border:1px solid #ccc;padding:8px;\"\u003eGermany\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe DSQC400E cuts servo enable and brake signals in under 10 ms, meeting the fast response required for personnel protection in robotic cells. Eight dual-channel safety inputs accept emergency stop, gate switch, and light curtain signals directly, reducing external relay count. The board carries PLd\/SIL2 certification for safety functions, and its CAN bus interface integrates with the IRC5 controller without additional wiring. A 150,000-hour MTBF supports long service intervals in continuous production environments.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What safety functions does the DSQC400E monitor?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e Emergency stop, safety gates, and light curtains, cutting servo enable and brakes within 10 ms.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: What safety certification does the board carry?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e PLd (Cat. 3) and SIL2, with 8 dual-channel inputs and 5 relay outputs.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What are the power and communication ratings?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e 24 V DC at 10 W, communicating over CAN bus with 5 V DC input signal voltage.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":67964112044164,"sku":"3HAC058424-001","price":149.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3HAC058424-001.jpg?v=1794057250","url":"https:\/\/www.etowonauto.com\/tk\/products\/3hac058424-001-safe-board-irc5-sil2-pld-abb","provider":"Etowon Auto","version":"1.0","type":"link"}