{"product_id":"3bdh000690r1-ci920as-abb-communication-interface","title":"3BDH000690R1 CI920AS ABB Communication Interface","description":"\u003ch2 style=\"color: #2c3e50; padding-bottom: 0; margin-top: 25px; margin-bottom: 15px;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"line-height: 1.5; color: #000000; margin-bottom: 30px;\"\u003e\n  The ABB \u003cstrong style=\"color: #003366;\"\u003e3BDH000690R1 CI920AS\u003c\/strong\u003e is a sophisticated communication interface designed for the Advant AC800M distributed control system. This module is specifically built to bridge the gap between high-level control logic and field instrumentation in demanding industrial sectors. With built-in redundancy capabilities, the CI920AS ensures maximum uptime and system availability. Its rugged design makes it suitable for hazardous locations, providing intrinsically safe connectivity without compromising signal speed or reliability.\n\u003c\/p\u003e\n\n\u003ch2 style=\"color: #2c3e50; margin-top: 35px; margin-bottom: 15px;\"\u003eCore Technical Advantages\u003c\/h2\u003e\n\n\u003ch3 style=\"color: #2c3e50; font-size: 1.1em; margin-bottom: 8px;\"\u003eExplosion Protection and Hazardous Safety\u003c\/h3\u003e\n\u003cp style=\"line-height: 1.5; color: #000000; margin-bottom: 20px;\"\u003e\n  Safety is a cornerstone of the CI920AS design. It is fully certified for ATEX Zone 1 environments, making it an ideal choice for oil and gas, chemical processing, and mining operations. By utilizing intrinsic safety principles, the module limits electrical and thermal energy to levels that cannot ignite a surrounding explosive atmosphere, ensuring the safety of both personnel and plant assets.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #2c3e50; font-size: 1.1em; margin-bottom: 8px;\"\u003eG3 Level Corrosion Resistance\u003c\/h3\u003e\n\u003cp style=\"line-height: 1.5; color: #000000; margin-bottom: 20px;\"\u003e\n  Industrial environments are often filled with airborne contaminants that can degrade sensitive electronics. The 3BDH000690R1 meets the ISA-S71.04 G3 standard for corrosion resistance. This means the module is protected against harsh gases and high humidity (up to 93 percent), allowing for a longer service life and reduced maintenance costs in coastal or chemically intensive locations.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #2c3e50; font-size: 1.1em; margin-bottom: 8px;\"\u003eOptimized Form Factor for Cabinet Density\u003c\/h3\u003e\n\u003cp style=\"line-height: 1.5; color: #000000; margin-bottom: 35px;\"\u003e\n  With a width of only 20mm, the CI920AS allows for high-density mounting within automation cabinets. This compact footprint, combined with its lightweight 0.14 kg profile, facilitates easy installation and integration into existing AC800M racks. Despite its small size, it maintains full functional integrity and climatic resilience within a wide temperature spectrum.\n\u003c\/p\u003e\n\n\u003ch2 style=\"color: #2c3e50; margin-top: 35px; margin-bottom: 15px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 40px; border: 1px solid #dfe4e8; color: #000000;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background-color: #f4f6f8;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dfe4e8; font-weight: bold; width: 40%;\"\u003eModel Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dfe4e8;\"\u003e3BDH000690R1 CI920AS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dfe4e8; font-weight: bold;\"\u003eSystem Series\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dfe4e8;\"\u003eAdvant AC800M\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f4f6f8;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dfe4e8; font-weight: bold;\"\u003eHazardous Certification\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dfe4e8;\"\u003eATEX Zone 1 (Explosion Proof)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dfe4e8; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dfe4e8;\"\u003e-20 to +60 Degrees Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f4f6f8;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dfe4e8; font-weight: bold;\"\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dfe4e8;\"\u003eMax 93% (ISA-S71.04 G3 Compliant)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dfe4e8; font-weight: bold;\"\u003eDimensions (W x D x H)\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dfe4e8;\"\u003e20 x 104 x 104 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f4f6f8;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dfe4e8; font-weight: bold;\"\u003eModule Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dfe4e8;\"\u003e0.14 kg (0.31 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color: #2c3e50; margin-top: 35px; margin-bottom: 15px;\"\u003eInstallation and Compliance\u003c\/h2\u003e\n\u003cul style=\"line-height: 1.6; color: #000000; margin-bottom: 40px; list-style-type: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 10px;\"\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e Supports redundant module pairs to ensure continuous operation in the event of a primary interface failure.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 10px;\"\u003e\n\u003cstrong\u003eEnvironmental Standards:\u003c\/strong\u003e Fully compliant with RoHS and WEEE directives for environmental protection and recycling.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 10px;\"\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Vertical or horizontal DIN rail mounting is supported within standard AC800M I\/O terminal bases.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"color: #2c3e50; margin-top: 35px; margin-bottom: 15px;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\n\u003cp style=\"margin-bottom: 4px; font-weight: bold; color: #2c3e50;\"\u003eQ1: What does the ATEX Zone 1 certification imply for installation?\u003c\/p\u003e\n\u003cp style=\"margin-top: 0; margin-bottom: 15px; color: #000000;\"\u003eA1: This means the CI920AS can be safely installed in areas where an explosive atmosphere is likely to occur occasionally during normal operation, provided it is part of an intrinsically safe system.\u003c\/p\u003e\n\n\u003cp style=\"margin-bottom: 4px; font-weight: bold; color: #2c3e50;\"\u003eQ2: What is the recommended shipping weight for this module?\u003c\/p\u003e\n\u003cp style=\"margin-top: 0; margin-bottom: 15px; color: #000000;\"\u003eA2: While the net weight is 0.14 kg, for international logistics, we suggest a gross shipping weight of approximately 0.35 kg to include protective anti-static padding and industrial-grade boxing.\u003c\/p\u003e\n\n\u003cp style=\"margin-bottom: 4px; font-weight: bold; color: #2c3e50;\"\u003eQ3: How does G3 corrosion resistance benefit the module?\u003c\/p\u003e\n\u003cp style=\"margin-top: 0; margin-bottom: 20px; color: #000000;\"\u003eA3: G3 rating protects the internal PCB and components from severe sulfur and chloride levels, preventing trace corrosion that often causes intermittent communication errors in wastewater or industrial plant environments.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51050501046404,"sku":"CI920AS","price":145.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CI920AS.jpg?v=1779111886","url":"https:\/\/www.etowonauto.com\/tk\/products\/3bdh000690r1-ci920as-abb-communication-interface","provider":"Etowon Auto","version":"1.0","type":"link"}