{"product_id":"3500-60-01-00-bently-nevada-internal-terminations-unit","title":"3500\/60-01-00 Bently Nevada | Internal Terminations Unit","description":"\u003ch2 style=\"color: #005596; font-weight: bold;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3500\/60-01-00\u003c\/strong\u003e is a high-performance temperature monitor designed for continuous machinery protection. It accepts input from up to six Resistance Temperature Detectors (RTD) or Thermocouples (TC), providing critical thermal monitoring for rotating equipment like turbines, pumps, and motors. By converting sensor data into actionable alarms and proportional 4-20 mA signals, this module prevents catastrophic failure due to overheating and ensures long-term operational reliability.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #005596; font-weight: bold;\"\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cp\u003eThe configuration for the \u003cstrong\u003e3500\/60-01-00\u003c\/strong\u003e model is defined as follows:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eI\/O Module Type (01):\u003c\/strong\u003e RTD\/TC Non-isolated I\/O Module with Internal Terminations. This allows for direct field wiring to the back of the 3500 rack without external terminal blocks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAgency Approval (00):\u003c\/strong\u003e No specific hazardous area approvals selected (Standard Version).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"color: #005596; font-weight: bold;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n    \u003cth style=\"border: 1px solid #ddd; padding: 10px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n    \u003cth style=\"border: 1px solid #ddd; padding: 10px; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eInput Signal Count\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e1 to 6 RTD or TC signals\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eThermocouple Types\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eType E, J, K, T\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eRTD Support\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003ePlatinum (100Ω), Nickel (120Ω), Copper (10Ω)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eAnalog Output\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e+4 to +20 mA per channel\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003ePower Consumption\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e7 Watts (Nominal)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eAccuracy\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e±3 °C at 25 °C (Standard Rack)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eRack Space\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e1 Front Slot (Monitor), 1 Rear Slot (I\/O)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eDimensions\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e241.3 mm x 24.4 mm x 241.8 mm\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color: #005596; font-weight: bold;\"\u003eEngineering \u0026amp; Installation Guide\u003c\/h2\u003e\n\u003ch3 style=\"color: #333;\"\u003eSystem Placement\u003c\/h3\u003e\n\u003cp\u003eThe 3500\/60 system consists of the main monitor module and a corresponding I\/O module. The monitor fits into any full-height slot in the front of the 3500 rack, while the non-isolated I\/O module must be installed in the same slot position on the rear of the rack.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #333;\"\u003eInternal Termination Wiring\u003c\/h3\u003e\n\u003cp\u003eThis module features internal terminations, allowing field wiring to connect directly to the I\/O module. When using 3-wire or 4-wire RTDs, ensure that lead wire lengths are minimized or properly compensated in the software to maintain high measurement precision.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #333;\"\u003eAlarm Delay \u0026amp; Logic\u003c\/h3\u003e\n\u003cp\u003eAlert and Danger setpoints are fully programmable via the 3500 rack configuration software. Users can set alarm time delays (1 to 60 seconds) to filter out transient thermal spikes, ensuring that trips only occur during sustained over-temperature conditions.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #005596; font-weight: bold;\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003ch3 style=\"color: #333;\"\u003eNon-Contact \u0026amp; Precision Measurement\u003c\/h3\u003e\n\u003cp\u003eThe 3500\/60 offers high-impedance inputs (10 MΩ) and dedicated cold junction compensation for thermocouples, ensuring signal integrity even in electrically noisy industrial environments.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #333;\"\u003eReal-time Visual Diagnostics\u003c\/h3\u003e\n\u003cp\u003eThe front panel includes an \u003cstrong\u003eOK LED\u003c\/strong\u003e to indicate module health, a \u003cstrong\u003eTX\/RX LED\u003c\/strong\u003e for communication status across the backplane, and a \u003cstrong\u003eBypass LED\u003c\/strong\u003e to warn operators when machinery protection is inactive during testing.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #333;\"\u003eComprehensive Recorder Function\u003c\/h3\u003e\n\u003cp\u003eUnlike basic sensors, the 3500\/60 provides individual 4-20 mA outputs for every channel. These outputs are short-circuit protected and do not affect the monitor’s internal alarm logic if the recorder loop is compromised.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #005596; font-weight: bold;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the difference between the 3500\/60-01-00 and versions with an 01 or 02 suffix?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: The suffix \"00\" indicates that this module does not have specific ATEX\/CSA hazardous area agency approvals. It is designed for use in standard industrial settings where these certifications are not required.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Does the module support 2-wire RTDs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: While optimized for 3-wire and 4-wire RTDs to provide better accuracy, 2-wire RTDs can be used but may result in lower accuracy due to the lack of lead-wire resistance compensation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Can I monitor different types of sensors on one module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Yes, the 3500\/60 can simultaneously process signals from both RTDs and Thermocouples across its six channels, provided each channel is correctly configured in the 3500 software.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51822025867396,"sku":"3500\/60-01-00","price":412.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_60-01-00.jpg?v=1777797608","url":"https:\/\/www.etowonauto.com\/tk\/products\/3500-60-01-00-bently-nevada-internal-terminations-unit","provider":"Etowon Auto","version":"1.0","type":"link"}