{"product_id":"330130-070-00-05-3300-xl-non-armored-cable-bently-nevada","title":"330130-070-00-05 3300 XL Non-Armored Cable Bently Nevada","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003e330130-070-00-05\u003c\/strong\u003e is a premium 7.0-meter non-armored standard extension cable manufactured in the U.S.A. for the industry-standard Bently Nevada 3300 XL 8mm Proximity Transducer System. This high-precision coaxial cable transmits critical eddy current frequency signals between proximity probes and Proximitor Sensors. It plays an indispensable role in monitoring shaft vibration, position, and radial speed on high-speed rotating machinery—such as steam turbines, centrifugal compressors, and large industrial pumps—ensuring reliable data for critical asset protection loops.\u003c\/p\u003e\n\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDetailed Suffix Logic Breakdown:\u003c\/strong\u003e \n    \u003cul\u003e\n      \u003cli\u003e\n\u003cstrong\u003e-070:\u003c\/strong\u003e Configures a precise total electrical and physical cable length of 7.0 meters (22.9 feet).\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003e-00:\u003c\/strong\u003e Specifies a standard, lightweight non-armored cable configuration for optimized routing within conduit channels.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003e-05:\u003c\/strong\u003e Confirms international hazardous area safety approvals including CSA, ATEX, and IECEx certifications.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEngineered Electrical Performance:\u003c\/strong\u003e Features strict factory-calibrated DC resistance tolerances ($1.54 \\pm 0.23\\,\\Omega$ core resistance) to prevent signal drift and maintain baseline loop calibration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized Capacitance Profile:\u003c\/strong\u003e Maintains a low typical capacitance of 69.9 pF\/m (21.3 pF\/ft), preventing signal attenuation and roll-off over extended measurement loops.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Deployment Ready:\u003c\/strong\u003e Certified for implementation in volatile environments when integrated with nonincendive circuits or isolated safety barriers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eSpecification Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e330130-070-00-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eManufacturer \/ Origin\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eBently Nevada \/ Made in U.S.A.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eCable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e7.0 meters (22.9 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eCable Protection Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eStandard Cable (Non-Armored)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eCore Resistance ($R_{CORE}$)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e1.54 $\\pm$ 0.23 $\\Omega$ (Center Conductor to Center Conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eJacket Resistance ($R_{JACKET}$)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0.46 $\\pm$ 0.09 $\\Omega$ (Outer Conductor to Outer Conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eTypical Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e69.9 pF\/m (21.3 pF\/ft)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eTotal Mass Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e34 g\/m (Total net mass: 0.204 kg)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eAgency Approvals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eCSA, ATEX, IECEx\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eTransducer Linear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e2 mm (80 mils), spans from 0.25 to 2.3 mm (10 to 90 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation \u0026amp; Maintenance Guide\u003c\/h2\u003e\n\u003ch3\u003eConnector Sealing Constraints\u003c\/h3\u003e\n\u003cp\u003eEach 330130-070-00-05 cable ships with specialized silicone sealing tape. While this tape can replace rigid mechanical connector protectors in mild environments, you must never utilize silicone tape if the probe-to-extension connector joint faces direct exposure to corrosive turbine oil. Use oil-tight connector protectors instead.\u003c\/p\u003e\n\n\u003ch3\u003eField Wiring and Monitor Distance\u003c\/h3\u003e\n\u003cp\u003eWhen routing data from the Proximitor Sensor to a monitoring rack, employ high-quality 3-conductor shielded triad field wiring (0.2 to 1.5 mm² or 16 to 24 AWG) with tinned leads. Keep the maximum field wiring distance below 305 meters (1,000 feet) to prevent high-frequency signal roll-off or amplitude attenuation.\u003c\/p\u003e\n\n\u003ch3\u003ePower Rail and Barrier Matching\u003c\/h3\u003e\n\u003cp\u003eThe companion Proximitor Sensor requires a stable -17.5 Vdc to -26 Vdc supply for nonincendive loops, drawing 12 mA maximum. If safety barriers are installed, the voltage must remain restricted between -23 Vdc and -26 Vdc. Operating the loop at a voltage more positive than -23.5 Vdc can degrade the 2 mm linear calibration spectrum.\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExceptional Moisture Stability:\u003c\/strong\u003e Exhibits less than a 3% change in Average Scale Factor (ASF) even when tested across continuous 93% relative humidity for 56 straight days under IEC standard 68-2-3 conditions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReduced Mechanical Weight Profile:\u003c\/strong\u003e Weighing only 34 g\/m compared to the 103 g\/m armored variant, this standard profile puts significantly less physical stress on suspended junction layouts.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlawless System Accuracy:\u003c\/strong\u003e Pre-calibrated to deliver full dynamic accuracy when matched with standard AISI 4140 steel targets, a 3300 XL 8mm probe, and a -24 Vdc source gapped at 1.27 mm (50 mils).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the main structural difference between the -00 and -01 cable option?\u003c\/strong\u003e\u003cbr\u003e\nA1: The -00 suffix denotes a lightweight standard cable profile lacking external metal wrap. Option -01 includes a heavy stainless steel flexible armor outer layer. Use -00 inside protective metal conduits or wiring trays.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Why is silicone tape banned in areas exposed to turbine oil?\u003c\/strong\u003e\u003cbr\u003e\nA2: Turbine oil can degrade and break down silicone adhesives over time. If fluid bypasses the tape barrier and coats the coaxial interface, it creates signal contamination, causing false vibration alarms or system trips.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Does this 7-meter extension cable include FluidLoc liquid mitigation?\u003c\/strong\u003e\u003cbr\u003e\nA3: No, the -00 option is a standard high-performance cable. If your engineering prints mandate internal oil-block seals to prevent migration through the cable core, a specialized FluidLoc-configured assembly variant must be specified.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047729299588,"sku":"330130-070-00-05","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/330130-070-00-05-1.jpg?v=1779115187","url":"https:\/\/www.etowonauto.com\/tk\/products\/330130-070-00-05-3300-xl-non-armored-cable-bently-nevada","provider":"Etowon Auto","version":"1.0","type":"link"}