{"product_id":"1763-nc01-allen-bradley-communication-cable-channel-0-rs-485","title":"1763-NC01 Allen-Bradley Communication Cable Channel 0 RS-485","description":"\u003ch2 style=\"color: #2c3e50; border-bottom: none; padding-bottom: 6px;\"\u003eAllen-Bradley \u003cspan style=\"color: #2980b9; font-weight: bold;\"\u003e1763-NC01\u003c\/span\u003e MicroLogix 1100 Communication Cable\u003c\/h2\u003e\n\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eAllen-Bradley \u003cspan style=\"color: #2980b9; font-weight: bold;\"\u003e1763-NC01\u003c\/span\u003e is a communication cable designed for MicroLogix 1100 series controllers. Connects Channel 0 to RS-485 for effective networking in automation applications. 30 centimeter length with 8 pin Mini DIN connector and 6 pin terminal block. Supports DH-485, Modbus RTU, and DF1 half duplex protocols. Approved for Class I Division 2 applications.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background: #f8fafc;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #2c3e50; color: white;\"\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #ccc;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #ccc;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e1763-NC01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eMicroLogix 1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eType\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eCommunication Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eLength\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e30 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eConnector End 1\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e8 pin Mini DIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eConnector End 2\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e6 pin terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eInterface\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eRS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eProtocols\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eDH-485, Modbus RTU, DF1 half duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eCompatibility\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eMicroLogix 1100 systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eHazardous Location\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eClass I Division 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e0.1 kg (0.22 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cp\u003eConnect 8 pin Mini DIN connector to Channel 0 port on MicroLogix 1100 controller. Wire RS-485 network to 6 pin terminal block. Keep cable length short for compact setups. Verify proper termination for RS-485 networks. Approved for Class I Division 2 hazardous locations.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cp\u003eConnects Channel 0 to RS-485 for networking. 30 cm length for compact installations. 8 pin Mini DIN to 6 pin terminal block. Supports DH-485 communication. Supports Modbus RTU master and slave networks. Supports DF1 half duplex master and slave configurations. Approved for Class I Division 2 applications.\u003c\/p\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e What protocols does this cable support?\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e DH-485, Modbus RTU master and slave, and DF1 half duplex master and slave configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e What is the cable length?\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e 30 centimeters. Features 8 pin Mini DIN connector on one end and 6 pin terminal block on the other.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e Is this cable approved for hazardous locations?\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e Yes. Approved for Class I Division 2 applications. Suitable for industrial operations requiring this rating.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67931473739908,"sku":"1763-NC01","price":154.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1763-NC01_449f2f33-c767-445f-a8cc-b89d9fd0ad99.jpg?v=1795256541","url":"https:\/\/www.etowonauto.com\/tk\/products\/1763-nc01-allen-bradley-communication-cable-channel-0-rs-485","provider":"Etowon Auto","version":"1.0","type":"link"}