{"product_id":"07-do-90-s-gjr5250800r202-abb-binary-output-safety-module","title":"07 DO 90-S GJR5250800R202 | ABB Binary Output Safety Module","description":"\u003ch2 style=\"color: #0055A4;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0055A4;\"\u003eABB 07 DO 90-S\u003c\/strong\u003e (GJR5250800R202) is a safety-related binary output module with 8 electrically isolated outputs. It operates on 24V DC and delivers up to 0.5A per channel with 4A total module current. Designed for safety-critical applications, it features electronic short-circuit protection and inductive load limiting.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #0055A4;\"\u003eCore Functionality\u003c\/h2\u003e\n\u003cp\u003eThe 07 DO 90-S controls 8 binary output channels with electrical isolation as a group. It limits inductive interrupt voltages using diodes and supports inductive loads up to 0.5Hz switching frequency. The module monitors 0-signal output levels; if an output exceeds 8V while in state 0, the module shuts down and generates an error. Test signals under 1ms verify output integrity.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #0055A4;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; font-size:14px;\"\u003e\n  \u003ctr style=\"background:#f2f2f2;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eOrder Number\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e07 DO 90-S (GJR5250800R202)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eOutputs per Module\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e8\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eRated Voltage (UP \/ L+)\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e24V DC ±5% ripple\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eVoltage Range\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e20.4V to 28.8V DC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eMax Load Current (per ch)\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e0.5A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eTotal Current (8 outputs)\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e4A max\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eLeakage Current (0 signal)\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e0.3mA max\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eLamp Load\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e5W max\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eSignal Delay (0→1 \/ 1→0)\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e8 ms\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eOutput Level (0 \/ 1 signal)\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e0-3V \/ \u0026gt;UP-2.5V\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eInductive Switching\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e0.5 Hz max (diode limited)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eShort-Circuit Protection\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eElectronic\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eIsolation Test Voltage\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e800V DC (bus) \/ 500V DC (outputs)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCurrent Consumption (UP \/ L+)\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e0.2A + load \/ 100mA\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003ePower Dissipation\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e15W max\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCable Length (shielded\/unshielded)\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e1000m \/ 600m\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eConductor Cross Section\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e1 x 2.5 mm² max\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eTightening Torque\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e0.5 Nm max\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e120 x 140 x 85 mm\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e400 g\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color: #0055A4;\"\u003eInstallation Guide\u003c\/h2\u003e\n\u003cp\u003eMount the 07 DO 90-S on DIN rail. Connect 24V DC process voltage (UP) and supply voltage (L+) per VDE551 requirements. Wire outputs to field devices using conductors up to 2.5 mm². Tighten terminals to 0.5 Nm maximum. Use shielded cable for runs up to 1000m, unshielded up to 600m. Ensure supply voltages rise to at least 19V within 40ms after power-up.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #0055A4;\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThis safety-related module delivers 8 isolated outputs with electronic short-circuit protection. Diode limiting handles inductive loads safely. The module monitors 0-signal levels and shuts down on fault detection. Buffered voltage interruption for L+ exceeds 10ms. CE safety certification (S-CE) ensures compliance with safety standards.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #0055A4;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How many outputs and current rating?\u003c\/strong\u003e\u003cbr\u003e\nA1: 8 outputs, 0.5A per channel, 4A total. Leakage current 0.3mA max at 0 signal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What protection features are included?\u003c\/strong\u003e\u003cbr\u003e\nA2: Electronic short-circuit protection. Diode limiting for inductive interrupt voltages. 0-signal monitoring shuts down module on fault.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What are the supply and isolation ratings?\u003c\/strong\u003e\u003cbr\u003e\nA3: 24V DC ±5% (20.4-28.8V range). Isolation 800V DC to bus, 500V DC to outputs. Weight 400g.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":67648059310212,"sku":"07DO90-S","price":164.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/07DO90-S.jpg?v=1792851888","url":"https:\/\/www.etowonauto.com\/tk\/products\/07-do-90-s-gjr5250800r202-abb-binary-output-safety-module","provider":"Etowon Auto","version":"1.0","type":"link"}