{"title":"Woodward","description":"\u003cp\u003eWoodward products are widely used in turbine control, engine management, and power generation systems. Our Woodward category includes controllers, power modules, and interface components designed for precise speed, load, and energy control in demanding industrial and utility environments.\u003c\/p\u003e","products":[{"product_id":"woodward-5466-352-processor-control-module","title":"Woodward 5466-352 - Processor Control Module","description":"\u003ch2\u003e\u003cstrong\u003eMicroNet Control Processor Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2196f3;\"\u003eWoodward 5466-352\u003c\/strong\u003e Netcon CPU-040 manages MicroNet systems. This Woodward control module ensures reliable network operations. It provides sophisticated control for industrial applications.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e \u003cstrong\u003eWoodward 5466-352\u003c\/strong\u003e Netcon CPU-040\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Netcon CPU-040 Control Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl System:\u003c\/strong\u003e Version 2.08 compatible\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor:\u003c\/strong\u003e 68030 Microprocessor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e Dual-Ported RAM on VME bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWatchdog Logic:\u003c\/strong\u003e Automatic IOLOCK on CPU failure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIOLOCK State:\u003c\/strong\u003e De-energizes outputs during failure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Type:\u003c\/strong\u003e Panel Mount installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.88 kg module weight\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual Reset:\u003c\/strong\u003e Available with LED indications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegration:\u003c\/strong\u003e Designed for MicroNet architecture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features \u0026amp; Benefits\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePowerful \u003cstrong style=\"color: #2196f3;\"\u003e68030 processor\u003c\/strong\u003e for fast control\u003c\/li\u003e\n\u003cli\u003eDual-ported RAM enables efficient communication\u003c\/li\u003e\n\u003cli\u003eWatchdog logic ensures system reliability\u003c\/li\u003e\n\u003cli\u003eIOLOCK state protects connected equipment\u003c\/li\u003e\n\u003cli\u003ePanel mounting simplifies installation\u003c\/li\u003e\n\u003cli\u003eClear LED indications for status monitoring\u003c\/li\u003e\n\u003cli\u003eManual reset option for system recovery\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the Woodward 5466-352 CPU module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eWoodward 5466-352\u003c\/strong\u003e is a Netcon CPU-040 control module. It processes control logic in MicroNet systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does IOLOCK state do?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIOLOCK de-energizes all output circuits during CPU failure. This prevents unsafe system operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat processor does this module use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt uses a 68030 microprocessor. This provides reliable processing for control applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAuthor: Etowon Auto\u003c\/strong\u003e\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":51047906541700,"sku":"5466-352","price":145.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/5466-352.jpg?v=1769242458"},{"product_id":"woodward-5501-381-triple-module-redundant-power-supply","title":"Woodward 5501-381 Triple Module Redundant Power Supply","description":"\u003ch2\u003e\u003cstrong\u003eTriple Module Redundant Power Supply\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0066cc;\"\u003eWoodward 5501-381\u003c\/strong\u003e provides reliable redundant power. This MicroNet TMR power supply ensures continuous system operation. It offers high availability for critical applications.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e \u003cstrong\u003eWoodward 5501-381\u003c\/strong\u003e\/MicroNet TMR\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e High Voltage AC Power Supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Type:\u003c\/strong\u003e MicroNet Triple Module Redundant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 220 VAC standard input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e 47 to 63 Hz operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Power:\u003c\/strong\u003e 1250 VA capacity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Current:\u003c\/strong\u003e 6.7 A input current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHoldup Time:\u003c\/strong\u003e 1 cycle at 220 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 22 kg \/ 48 lbs in chassis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Fault LED:\u003c\/strong\u003e Indicates power input issues\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Fault LED:\u003c\/strong\u003e Signals internal faults\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvertemperature LED:\u003c\/strong\u003e Warns of overheating conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOK LED:\u003c\/strong\u003e Green light for normal operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is triple module redundancy?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTriple module redundancy uses three independent modules. It ensures continuous power even if one module fails.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat voltage does the Woodward 5501-381 accept?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eWoodward 5501-381\u003c\/strong\u003e accepts 220 VAC input voltage. It operates within 47-63 Hz frequency range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat do the LED indicators show?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLEDs show input faults, power supply faults, temperature issues, and normal operation status.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAuthor: Etowon Auto\u003c\/strong\u003e\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":51047906574468,"sku":"5501-381","price":152.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/5501-381.jpg?v=1769242081"},{"product_id":"woodward-8200-1205-discrete-output-module-16-channels","title":"Woodward 8200-1205 Discrete Output Module 16 Channels","description":"\u003ch2\u003e\u003cstrong\u003eReliable Discrete Output Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2196f3;\"\u003eWoodward 8200-1205\u003c\/strong\u003e provides industrial output control. This Woodward module offers 16 discrete output channels. It ensures reliable operation for automation systems.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e \u003cstrong\u003eWoodward 8200-1205\u003c\/strong\u003e Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Type:\u003c\/strong\u003e Discrete Outputs (DOs) for control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Outputs:\u003c\/strong\u003e 16 independent channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 24 V DC standard voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Rating:\u003c\/strong\u003e 0.5 A maximum per output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e 500 V input-output isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e LinkNet Protocol interface\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e -20°C to +60°C operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Type:\u003c\/strong\u003e DIN rail mount installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features \u0026amp; Benefits\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e16 \u003cstrong style=\"color: #2196f3;\"\u003ediscrete outputs\u003c\/strong\u003e for flexible control\u003c\/li\u003e\n\u003cli\u003eHigh isolation voltage protects connected equipment\u003c\/li\u003e\n\u003cli\u003eLinkNet protocol enables easy system integration\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting simplifies installation\u003c\/li\u003e\n\u003cli\u003eCompact design saves control panel space\u003c\/li\u003e\n\u003cli\u003eReliable performance in industrial environments\u003c\/li\u003e\n\u003cli\u003eStandard 24V DC suits most control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePackaging \u0026amp; Shipping\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOne \u003cstrong\u003eWoodward 8200-1205\u003c\/strong\u003e output module per box\u003c\/li\u003e\n\u003cli\u003eIncludes DIN rail mounting clips\u003c\/li\u003e\n\u003cli\u003eProfessional protective packaging\u003c\/li\u003e\n\u003cli\u003eGlobal shipping via FedEx, UPS, DHL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the Woodward 8200-1205 used for?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eWoodward 8200-1205\u003c\/strong\u003e controls industrial devices. It provides 16 output channels for automation systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat communication protocol does it use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt uses LinkNet Protocol for communication. This enables integration with Woodward control systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the output current capacity?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach output handles 0.5 A maximum current. This suits most industrial control applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAuthor: Etowon Auto\u003c\/strong\u003e\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":51047915978884,"sku":"8200-1205","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/8200-1205-1.jpg?v=1769241922"},{"product_id":"woodward-8200-177-speed-sensing-digital-driver-unit","title":"Woodward 8200-177 Speed Sensing Digital Driver Unit","description":"\u003ch2\u003e\u003cstrong\u003eReliable Speed Sensing Digital Driver\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #4caf50;\"\u003eWoodward 8200-177\u003c\/strong\u003e digital driver provides accurate speed sensing. This Woodward device ensures reliable performance in harsh conditions. It offers efficient speed control for industrial applications.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e \u003cstrong\u003eWoodward 8200-177\u003c\/strong\u003e Digital Driver\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 120 VAC primary input power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Input:\u003c\/strong\u003e 18 to 32 V DC operating range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Rating:\u003c\/strong\u003e 24 V DC, 16 A output capacity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpeed Sensing:\u003c\/strong\u003e 1 to 30 VAC sensing range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Isolation:\u003c\/strong\u003e 0-60 Hz at 1000 Vrms protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous Power:\u003c\/strong\u003e 3.3 amps consumption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +85°C wide range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Stub Length:\u003c\/strong\u003e 300 mm connection limit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 461 mm H x 265 mm W x 59 mm D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 24.0 lbs \/ 10.9 kg unit weight\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Type:\u003c\/strong\u003e 1.5 V DC Speed Bias configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEM Resolver Support:\u003c\/strong\u003e Yes, compatible support\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Source Rating:\u003c\/strong\u003e 95-130 performance rating\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the Woodward 8200-177 used for?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eWoodward 8200-177\u003c\/strong\u003e provides speed sensing and control. It drives equipment requiring precise speed management.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat temperature range does it support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt operates from -40°C to +85°C extreme temperatures. This suits harsh industrial environments perfectly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the output current capacity?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe device delivers 16 A at 24 V DC output. This powers various industrial control components effectively.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAuthor: Etowon Auto\u003c\/strong\u003e\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":51047916011652,"sku":"8200-177","price":256.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/8200-177-1.jpg?v=1769241484"},{"product_id":"woodward-8200-224-din-rail-signal-conditioning-module","title":"Woodward 8200-224 DIN Rail Signal Conditioning Module","description":"\u003ch2\u003e\u003cstrong\u003ePrecision Signal Conditioning Solution\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #003366;\"\u003eWoodward 8200-224\u003c\/strong\u003e provides reliable signal conditioning and isolation. This Woodward module ensures accurate current measurement in industrial systems. It converts and isolates signals with high precision.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e \u003cstrong\u003eWoodward 8200-224\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e ±10 mA to ±250 mA wide measurement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24 V DC ±20% for industrial use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signals:\u003c\/strong\u003e 0-10 V or 4-20 mA configurable options\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e 0.1% of Full Scale high accuracy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u0026lt; 1 ms for input step changes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Filter:\u003c\/strong\u003e 5 ms lag for signal smoothing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e 400 kΩ high impedance input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +70°C wide range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Sensitivity:\u003c\/strong\u003e 300 ppm\/°C stable performance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Rating:\u003c\/strong\u003e Up to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 20 W typical heat load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e RS-232 \/ RS-485 optional interface\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 5.0\" x 4.5\" x 3.0\" (127x114x76 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.5 lbs \/ 0.68 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the Woodward 8200-224 do?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eWoodward 8200-224\u003c\/strong\u003e conditions and isolates current signals. It converts industrial signals to standard outputs like 4-20mA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the input current range?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt accepts currents from ±10 mA to ±250 mA. This range covers most industrial current signal applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow accurate is this signal conditioner?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe device offers 0.1% linearity of full scale. This provides high precision for critical measurements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAuthor: Etowon Auto\u003c\/strong\u003e\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":51047916044420,"sku":"8200-224","price":174.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/8200-224-1.jpg?v=1769240143"},{"product_id":"woodward-8440-2165-voltage-current-monitoring-relay","title":"Woodward 8440-2165 Voltage Current Monitoring Relay","description":"\u003ch2\u003e\u003cstrong\u003eElectrical System Protection\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #ff9800;\"\u003eWoodward 8440-2165\u003c\/strong\u003e relay protects industrial equipment. This Woodward device provides reliable electrical monitoring.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e \u003cstrong\u003eWoodward 8440-2165\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Input:\u003c\/strong\u003e 100 VAC measurement capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Input:\u003c\/strong\u003e ..\/5 A for current transformers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e 45-65 Hz operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSync Accuracy:\u003c\/strong\u003e ±0.1 Hz precision\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e -20°C to 60°C operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 115\/230 VAC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e Over\/undervoltage, phase failure, ground fault\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAdvanced \u003cstrong style=\"color: #0066cc;\"\u003eprotection features\u003c\/strong\u003e for system safety\u003c\/li\u003e\n\u003cli\u003eWide temperature range for reliable operation\u003c\/li\u003e\n\u003cli\u003ePanel or standalone mounting options\u003c\/li\u003e\n\u003cli\u003eCompact 216x165x89 mm size\u003c\/li\u003e\n\u003cli\u003eDual power supply compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePackaging \u0026amp; Shipping\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOne \u003cstrong\u003eWoodward 8440-2165\u003c\/strong\u003e relay per box\u003c\/li\u003e\n\u003cli\u003eIncludes user manual\u003c\/li\u003e\n\u003cli\u003eShipped via FedEx, UPS, DHL\u003c\/li\u003e\n\u003cli\u003eTracking provided after dispatch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the Woodward 8440-2165 do?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eWoodward 8440-2165\u003c\/strong\u003e monitors voltage and current. It protects equipment from electrical faults.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat frequency range does it support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt works with 45-65 Hz systems. This covers 50 Hz and 60 Hz power grids.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I mount this relay?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse panel mounting for control cabinets. Choose standalone for test setups.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":51047916339332,"sku":"8440-2165","price":256.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/8440-2165-1.jpg?v=1769239136"},{"product_id":"9905-970-input-module-woodward-linknet-system","title":"9905-970 Input Module | Woodward LinkNet System","description":"\u003ch2\u003eWoodward 9905-970 LinkNet 6-Channel Input Module\u003c\/h2\u003e\n\u003cp\u003eThe Woodward \u003cstrong style=\"color: #d35400;\"\u003e9905-970\u003c\/strong\u003e is a versatile input module for LinkNet systems. This 6-channel module handles analog and digital signals. It provides reliable data acquisition in harsh industrial environments. The \u003cstrong\u003e9905-970\u003c\/strong\u003e ensures accurate measurement for engine and turbine control applications.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eModule Identification\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Woodward Governor Company\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e \u003cstrong\u003e9905-970\u003c\/strong\u003e input module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e LinkNet 6-Channel Input Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Woodward LinkNet networks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Style:\u003c\/strong\u003e Panel mount installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eElectrical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #27ae60;\"\u003e24 V DC\u003c\/span\u003e nominal operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Current:\u003c\/strong\u003e 12 A operating capacity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Protection:\u003c\/strong\u003e 900 V DC surge protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e 33K Ohms signal impedance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Channels:\u003c\/strong\u003e 6 independent input points\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Types:\u003c\/strong\u003e Analog and digital inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTD Support:\u003c\/strong\u003e 100 Ohm RTD compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePhysical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 14 x 11 x 4 inches (LxWxH)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 6 lbs (2.7 kg) approximate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e 24-character LED indicators\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Functions:\u003c\/strong\u003e Power, Status, Fault indication\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Rating:\u003c\/strong\u003e IP67 optional (verify specific)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +85°C range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e LinkNet protocol interface\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e Industrial-grade components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Panel or enclosure mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMount on industrial panel in protected enclosure\u003c\/li\u003e\n\u003cli\u003eConnect 24V DC power supply within specifications\u003c\/li\u003e\n\u003cli\u003eWire field signals to appropriate input channels\u003c\/li\u003e\n\u003cli\u003eConfigure LinkNet communication parameters\u003c\/li\u003e\n\u003cli\u003eSet up RTD or analog input scaling as required\u003c\/li\u003e\n\u003cli\u003eVerify proper grounding and shielding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eInput Channel Configuration\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Count:\u003c\/strong\u003e Six configurable inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Types:\u003c\/strong\u003e Voltage, current, RTD, digital\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpedance Matching:\u003c\/strong\u003e 33K Ohms input design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e Channel-to-channel separation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration:\u003c\/strong\u003e Field-adjustable settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat signals can the 9905-970 module accept?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e9905-970\u003c\/strong\u003e accepts analog voltages, RTD signals, and digital inputs across six channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the transient protection work?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt provides 900V DC surge protection against power line spikes and transients.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module operate in outdoor installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith optional IP67 rating, it can handle harsh environments when properly enclosed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the 24-character display?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe LED display shows channel values, status messages, and fault codes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I communicate with this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse Woodward's LinkNet protocol through the communication interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat maintenance does this module require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePeriodic calibration verification and environmental inspection are recommended.\u003c\/p\u003e\n\u003cp\u003eFor technical support or to order the \u003cstrong\u003e9905-970\u003c\/strong\u003e, email \u003ca href=\"mailto:sale@etowonauto.com\"\u003esale@etowonauto.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eContent provided by Etowon Auto.\u003c\/em\u003e\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":51047920369796,"sku":"9905-970","price":259.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/9905-970.jpg?v=1768742923"},{"product_id":"woodward-5441-693-field-terminal-module","title":"Woodward 5441-693 Field Terminal Module","description":"\u003ch2\u003e\u003cstrong\u003eWoodward 5441-693 Field Terminal Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2c3e50;\"\u003eWoodward 5441-693\u003c\/strong\u003e provides reliable industrial control. This USA-made module is in stock and ready to ship.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCore Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cspan style=\"color: #2c3e50;\"\u003eWoodward\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e5441-693\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Field Terminal Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e USA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus:\u003c\/strong\u003e \u003cspan style=\"color: #27ae60;\"\u003eIn Stock\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e \u003cspan style=\"color: #27ae60;\"\u003e1.95 kg\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2980b9;\"\u003e24 optically isolated inputs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2980b9;\"\u003e5 ms signal refresh rate\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2980b9;\"\u003e1 ms time stamp resolution\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2980b9;\"\u003e13 relay outputs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #c0392b;\"\u003e24 VDC, 400 mA supply\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eShelf life: \u003cspan style=\"color: #d35400;\"\u003e1 year\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eShipping\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePackage includes module and documentation\u003c\/li\u003e\n\u003cli\u003eShips via FedEx, UPS, or DHL\u003c\/li\u003e\n\u003cli\u003eMost orders ship within 24 hours\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the main function?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e5441-693\u003c\/strong\u003e connects field devices to control systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy 1 ms time stamping?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt allows precise event sequencing and troubleshooting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow to choose correctly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVerify you need 24 inputs and 13 relay outputs. Confirm 24VDC power matches your system.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":51050472439940,"sku":"5441-693","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/5441-693-1.jpg?v=1769693751"},{"product_id":"woodward-netcon-5000b-sio-interface-module-5464-213","title":"Woodward Netcon 5000B SIO Interface Module | 5464-213","description":"\u003ch2\u003e\u003cstrong\u003eWoodward Netcon 5000B SIO Interface Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAuthor: Etowon Auto\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eWoodward Netcon 5000B\u003c\/strong\u003e connects control systems to serial devices. This industrial module ensures reliable communication. It works in tough environments with consistent performance.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Woodward \u003cstrong style=\"color: #d32f2f;\"\u003eNetcon 5000B\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e \u003cstrong style=\"color: #d32f2f;\"\u003e5464-213\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Power:\u003c\/strong\u003e 24VDC nominal, 10-60VDC range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e -25°C to +70°C operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Ports:\u003c\/strong\u003e 2 RS-232 ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaud Rates:\u003c\/strong\u003e 110 to 38,400 bps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e Modbus RTU and ASCII\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Panel mount design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 0-95% non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWide 10-60VDC input range\u003c\/li\u003e\n\u003cli\u003eWorks in extreme temperatures\u003c\/li\u003e\n\u003cli\u003eTwo configurable RS-232 ports\u003c\/li\u003e\n\u003cli\u003eSupports Modbus protocols\u003c\/li\u003e\n\u003cli\u003eClear status LEDs\u003c\/li\u003e\n\u003cli\u003eIndustrial durability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOne \u003cstrong\u003eNetcon 5000B\u003c\/strong\u003e module (5464-213)\u003c\/li\u003e\n\u003cli\u003eMounting hardware\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eShipping\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFedEx, UPS, DHL available\u003c\/li\u003e\n\u003cli\u003e1-2 business day processing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMount on clean, dry panel\u003c\/li\u003e\n\u003cli\u003eConnect 10-60VDC power\u003c\/li\u003e\n\u003cli\u003eAttach RS-232 devices\u003c\/li\u003e\n\u003cli\u003eSet baud rate and protocol\u003c\/li\u003e\n\u003cli\u003eVerify power LED lights\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What devices connect to this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Any RS-232 device - HMIs, scanners, printers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What baud rate should I use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Start with 9600 or 19200 baud.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this module durable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, designed for industrial environments.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":51050472472708,"sku":"5464-213","price":144.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/5464-213.jpg?v=1769693594"},{"product_id":"woodward-5464-643-48-channel-discrete-input-module","title":"Woodward 5464-643 | 48-Channel Discrete Input Module","description":"\u003ch2\u003e\u003cb\u003eWoodward 5464-643 Discrete Input Module\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cb\u003eWoodward 5464-643\u003c\/b\u003e is a 48-channel industrial input module. It provides reliable signal acquisition with optical isolation for control systems.\u003c\/p\u003e\n\u003ch2\u003e\u003cb\u003eCore Technical Specifications\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eManufacturer \u0026amp; Model:\u003c\/b\u003e \u003cspan style=\"color: #d9534f;\"\u003e\u003cb\u003eWoodward 5464-643\u003c\/b\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eChannels:\u003c\/b\u003e \u003cspan style=\"color: #d9534f;\"\u003e48 discrete inputs\u003c\/span\u003e with optical isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eInput Current:\u003c\/b\u003e \u003cspan style=\"color: #d9534f;\"\u003e3 mA\u003c\/span\u003e per channel requirement\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eVoltage Range:\u003c\/b\u003e \u003cspan style=\"color: #d9534f;\"\u003e18-32V DC\u003c\/span\u003e operating power\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eIsolation:\u003c\/b\u003e \u003cspan style=\"color: #d9534f;\"\u003e1500V AC\u003c\/span\u003e channel-to-ground protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCommunication:\u003c\/b\u003e Dual-port parallel interface\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTemperature:\u003c\/b\u003e \u003cspan style=\"color: #d9534f;\"\u003e-20°C to +70°C\u003c\/span\u003e operating range\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDimensions:\u003c\/b\u003e 152 x 76 x 20 mm panel mount\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cb\u003eKey Features\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e48 high-density input channels in compact design\u003c\/li\u003e\n\u003cli\u003eOptical isolation for noise immunity and safety\u003c\/li\u003e\n\u003cli\u003eWide operating voltage (18-32V DC) compatibility\u003c\/li\u003e\n\u003cli\u003eRed LED fault indicator for quick diagnostics\u003c\/li\u003e\n\u003cli\u003eIndustrial temperature range (-20°C to +70°C)\u003c\/li\u003e\n\u003cli\u003eCE, UL, RoHS compliance for quality assurance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cb\u003ePackage Contents\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWoodward \u003cb\u003e5464-643\u003c\/b\u003e Input Module\u003c\/li\u003e\n\u003cli\u003eMounting hardware set\u003c\/li\u003e\n\u003cli\u003eInstallation documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cb\u003eShipping \u0026amp; Delivery\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAvailable shipping: FedEx, UPS, DHL\u003c\/li\u003e\n\u003cli\u003eInternational shipping available\u003c\/li\u003e\n\u003cli\u003eStandard lead time: 2-5 business days\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cb\u003eFAQ\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eWhat applications suit this module?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eIndustrial automation, turbine control, generator monitoring, and PLC systems.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eHow is fault detection handled?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eIntegrated red fault LED provides immediate visual status indication.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eWhat power supply is needed?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eStandard 24V DC industrial power supply within 18-32V range.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":51050472505476,"sku":"5464-643","price":285.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/5464-643.jpg?v=1769693442"},{"product_id":"woodward-5466-258-discrete-i-o-module","title":"Woodward - 5466-258 Discrete I\/O Module","description":"\u003ch2\u003e\u003cstrong\u003eHigh-Density Discrete I\/O Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #ff5733;\"\u003eWoodward 5466-258\u003c\/strong\u003e provides comprehensive I\/O capabilities. This Woodward discrete I\/O module handles multiple signals efficiently. It offers reliable performance for industrial control systems.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e \u003cstrong\u003eWoodward 5466-258\u003c\/strong\u003e Discrete I\/O Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Discrete I\/O Module for digital signals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e 18 to 32 Vdc external input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Input:\u003c\/strong\u003e 18 to 32 Vdc operating range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Required:\u003c\/strong\u003e 6.5 Watts at 24 Vdc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Inputs:\u003c\/strong\u003e 48 discrete digital inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Type:\u003c\/strong\u003e Discrete (digital) signal inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Outputs:\u003c\/strong\u003e 24 discrete digital outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Type:\u003c\/strong\u003e Discrete (digital) signal outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e -40°C to +70°C (-40°F to +158°F)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features \u0026amp; Benefits\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHigh \u003cstrong style=\"color: #ff5733;\"\u003eI\/O density\u003c\/strong\u003e with 48 inputs, 24 outputs\u003c\/li\u003e\n\u003cli\u003eWide voltage range supports various systems\u003c\/li\u003e\n\u003cli\u003eExtended temperature range for harsh environments\u003c\/li\u003e\n\u003cli\u003eLow power consumption at 6.5 Watts\u003c\/li\u003e\n\u003cli\u003eReliable discrete signal processing\u003c\/li\u003e\n\u003cli\u003eCompact design for space-efficient installation\u003c\/li\u003e\n\u003cli\u003eSuitable for demanding industrial applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePackaging \u0026amp; Shipping\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOne \u003cstrong\u003eWoodward 5466-258\u003c\/strong\u003e I\/O module per package\u003c\/li\u003e\n\u003cli\u003eIncludes connection documentation\u003c\/li\u003e\n\u003cli\u003eSecure anti-static packaging\u003c\/li\u003e\n\u003cli\u003eGlobal shipping via FedEx, UPS, DHL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProvide 18-32 Vdc power supply\u003c\/li\u003e\n\u003cli\u003eConnect digital inputs from field devices\u003c\/li\u003e\n\u003cli\u003eWire outputs to controlled equipment\u003c\/li\u003e\n\u003cli\u003eEnsure proper signal voltage levels\u003c\/li\u003e\n\u003cli\u003eTest all I\/O channels before operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the Woodward 5466-258 used for?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eWoodward 5466-258\u003c\/strong\u003e handles digital input and output signals. It interfaces between control systems and field devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many I\/O channels does it have?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt provides 48 discrete inputs and 24 discrete outputs. This offers high I\/O density for complex systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat power supply does it require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt requires 18-32 Vdc power supply. The module consumes 6.5 Watts at 24 Vdc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAuthor: Etowon Auto\u003c\/strong\u003e\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":51050472538244,"sku":"5466-258","price":262.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/5466-258.jpg?v=1769242762"},{"product_id":"woodward-8237-1369-mpu-detection-turbine-protector","title":"Woodward 8237-1369 | MPU Detection Turbine Protector","description":"\u003ch2\u003e\u003cstrong\u003eAdvanced Turbine Overspeed Protection\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0073e6;\"\u003eWoodward ProTech-GII 8237-1369\u003c\/strong\u003e safeguards turbines from dangerous overspeed. This critical protection device monitors turbine acceleration precisely. It initiates automatic shutdown during over-acceleration events.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e \u003cstrong\u003eWoodward ProTech-GII 8237-1369\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary Function:\u003c\/strong\u003e Overspeed detection and turbine protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 330 x 445 x 159 mm unit size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 23 lbs before shipping\/10.4kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20 to +60 °C (-4 to +140 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -20 to +65 °C (-4 to +158 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Rating:\u003c\/strong\u003e Up to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Protection:\u003c\/strong\u003e IP56 rating when installed correctly\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Compliance:\u003c\/strong\u003e EN61000-6-4 emissions, EN61000-6-2 immunity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input Options:\u003c\/strong\u003e 115 Vac \/ 240 Vac \/ 125 Vdc or 24 Vdc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpeed Readout:\u003c\/strong\u003e 4-20 mA output range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e Modbus for remote monitoring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecial Coating:\u003c\/strong\u003e Sulfur-resistant protection against H₂S\/SO₂\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetection Method:\u003c\/strong\u003e MPU (Magnetic Pickup Unit) sensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface:\u003c\/strong\u003e 15-key configuration keypad per module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat turbines does the Woodward 8237-1369 protect?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eWoodward ProTech-GII 8237-1369\u003c\/strong\u003e protects hydro, steam, and gas turbines. It provides overspeed detection for various turbine applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the sulfur-resistant coating for?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis special coating protects against H₂S and SO₂ gas exposure. It extends device life in corrosive industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the automatic shutdown work?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe device detects over-acceleration through MPU sensors. It then initiates immediate shutdown to prevent equipment damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAuthor: Etowon Auto\u003c\/strong\u003e\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":51050480140420,"sku":"8237-1369","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/8237-1369.jpg?v=1769239834"},{"product_id":"woodward-8440-2165-panel-control-unit","title":"Woodward 8440-2165 Panel Control Unit","description":"\u003ch2\u003e\u003cstrong\u003eIndustrial Monitoring \u0026amp; Control Solution\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #003366;\"\u003eWoodward 8440-2165\u003c\/strong\u003e provides robust industrial monitoring. This Woodward unit handles demanding control applications with precision.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e \u003cstrong\u003eWoodward 8440-2165\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 8-35 V DC for flexible installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +70°C extreme range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e Clear 128x64 pixel graphic LCD screen\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 0-600 V AC wide measurement range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e 45-70 Hz operation capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Rating:\u003c\/strong\u003e IP65 front panel for dust and water\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e CAN, RS-485 Modbus, optional Ethernet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Inputs:\u003c\/strong\u003e 6 configurable inputs for sensors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Inputs:\u003c\/strong\u003e 8 inputs for status monitoring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Outputs:\u003c\/strong\u003e 4 outputs for alarm\/control actions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 192 x 144 x 55 mm compact size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Lightweight 0.9 kg design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features \u0026amp; Applications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWide \u003cstrong style=\"color: #0066cc;\"\u003evoltage input range\u003c\/strong\u003e for various systems\u003c\/li\u003e\n\u003cli\u003eMultiple communication protocols for integration\u003c\/li\u003e\n\u003cli\u003eIP65 protection for harsh industrial environments\u003c\/li\u003e\n\u003cli\u003eConfigurable inputs for customized monitoring\u003c\/li\u003e\n\u003cli\u003eCompact design saves panel space effectively\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePackaging \u0026amp; Shipping Details\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOne \u003cstrong\u003eWoodward 8440-2165\u003c\/strong\u003e unit per package\u003c\/li\u003e\n\u003cli\u003eComplete user manual included\u003c\/li\u003e\n\u003cli\u003eGlobal shipping via FedEx, UPS, DHL\u003c\/li\u003e\n\u003cli\u003eSecure packaging ensures safe delivery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the Woodward 8440-2165 used for?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eWoodward 8440-2165\u003c\/strong\u003e monitors and controls industrial processes. It reads various sensor inputs and outputs control signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat environments does it work in?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt operates in extreme temperatures from -40°C to +70°C. The IP65 rating protects against dust and water spray.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat communication options are available?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe device offers CAN, RS-485 Modbus, and optional Ethernet. This allows integration with various control systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAuthor: Etowon Auto\u003c\/strong\u003e\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":51050480304260,"sku":"8440-1546","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/8440-1546.jpg?v=1769239344"},{"product_id":"woodward-a8516-040-governor-6000-rpm-speed-control","title":"Woodward A8516-040 Governor | 6000 RPM Speed Control","description":"\u003ch2\u003eWoodward A8516-040 Speed Governor Actuator\u003c\/h2\u003e\n\u003cp\u003eThe Woodward \u003cstrong style=\"color: #d35400;\"\u003eA8516-040\u003c\/strong\u003e is a precision speed governor for engine control. This self-stabilizing actuator maintains accurate rotational speed. It provides reliable overspeed protection for turbines and engines. The \u003cstrong\u003eA8516-040\u003c\/strong\u003e ensures stable operation in demanding power generation applications.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eModel Identification\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Woodward Governor Company\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003eA8516-040\u003c\/strong\u003e speed governor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGovernor Type:\u003c\/strong\u003e Self-stabilizing rotary actuator\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary Function:\u003c\/strong\u003e Engine and turbine speed control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Power generation and mechanical drive\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eSpeed Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum RPM:\u003c\/strong\u003e \u003cspan style=\"color: #27ae60;\"\u003e6000 RPM\u003c\/span\u003e absolute limit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Range:\u003c\/strong\u003e 4000-6000 RPM normal operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDroop Setting:\u003c\/strong\u003e 6050 DROOP configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotation Direction:\u003c\/strong\u003e Clockwise (CW) operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverspeed Protection:\u003c\/strong\u003e OSTD trip detection system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePhysical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.8 kg (1.76 pounds)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e Robust industrial housing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface:\u003c\/strong\u003e Standard mechanical linkage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental:\u003c\/strong\u003e Industrial-grade components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does \"self-stabilizing\" mean for this governor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eA8516-040\u003c\/strong\u003e automatically maintains stable speed without external stabilization circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat engines is this governor compatible with?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt suits various gas engines and turbines requiring 4000-6000 RPM speed control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the overspeed protection work?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe OSTD system detects excessive RPM and triggers protective shutdown.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the droop setting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDroop allows slight speed variation with load changes for stable parallel operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this governor be adjusted for different speed ranges?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is factory set for 4000-6000 RPM operation with specific calibration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat maintenance does this actuator require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRegular inspection of mechanical linkages and calibration verification.\u003c\/p\u003e\n\u003cp\u003eFor technical specifications or to order the \u003cstrong\u003eA8516-040\u003c\/strong\u003e, contact \u003ca href=\"mailto:sale@etowonauto.com\"\u003esale@etowonauto.com\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eContent provided by Etowon Auto.\u003c\/em\u003e\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":51050487578756,"sku":"A8516-040","price":529.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/A8516-040-2.jpg?v=1768742643"},{"product_id":"8440-1934-woodward-genset-controller-breaker-display-12-24v","title":"8440-1934 Woodward Genset Controller Breaker Display 12\/24V","description":"\u003ch2 style=\"color: #005A9C;\"\u003e8440-1934 Woodward easYgen-2500 Breaker Control Operator Interface\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong style=\"color: #005A9C;\"\u003e8440-1934\u003c\/strong\u003e is a Woodward easYgen-2500 operator interface for breaker control. Features color LCD display, front panel mounting, 12\/24 Vdc supply, 19W max consumption. Includes 32\/32 discrete I\/O and 16\/4 analog I\/O. Designed for genset control and protection applications.\u003c\/p\u003e\n\n\u003ch3\u003eCore Technical Advantages\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBreaker Control:\u003c\/strong\u003e Dedicated operator interface for generator breaker management and synchronization.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eColor LCD Display:\u003c\/strong\u003e Large graphical display with multilingual support for easy operation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExtensive I\/O:\u003c\/strong\u003e 32 discrete inputs, 32 discrete outputs, 16 analog inputs, and 4 analog outputs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrue RMS Sensing:\u003c\/strong\u003e Class 1 accuracy for voltage (120\/480 VAC) and current (1A\/5A) measurements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVersatile Power:\u003c\/strong\u003e 12\/24 Vdc supply with wide 8-40 Vdc operating range, 19W max consumption.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIP66 Front Sealing:\u003c\/strong\u003e Front panel IP66 rated for harsh environments. Plastic housing, 282×217×99 mm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003ctable style=\"width:100%; border-collapse: collapse; font-size:14px;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color:#f0f0f0;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003e8440-1934\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDescription\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eeasYgen-2500 Breaker Control Operator Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e12\/24 Vdc (8 - 40 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e19 W Max\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eColor LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eFront Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e16 (0-500Ω, 0-20mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4 (±10V \/ ±20mA \/ PWM)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eVoltage Sensing\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e120\/480 VAC true RMS, Class 1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCurrent Sensing\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1A\/5A true RMS, Class 1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eHousing\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePlastic, Front Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDimensions (W×H×D)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e282 × 217 × 99 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSealing\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIP66 (front) \/ IP20 (rear)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eapprox. 1,850 g\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e-20 to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation \u0026amp; Maintenance Guide\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Front panel installation. Cutout dimensions follow Woodward easYgen-3200 specification. Plastic housing, 282×217×99 mm.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Connect 12\/24 Vdc (8-40 Vdc range). Ensure capacity for 19W max consumption.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage Sensing:\u003c\/strong\u003e Connect 120 VAC or 480 VAC true RMS inputs. Class 1 accuracy.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCurrent Sensing:\u003c\/strong\u003e Use 1A or 5A CTs. Isolated true RMS inputs with Class 1 accuracy.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eI\/O Wiring:\u003c\/strong\u003e 32 discrete I\/O (12\/24 Vdc range), 16 analog inputs (0-500Ω \/ 0-20mA), 4 analog outputs (±10V \/ ±20mA \/ PWM).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e Supports CAN open, J1939, Modbus RTU, and modem.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Operating temperature -20 to 70°C. IP66 front sealing for harsh conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eEngineering Advantages \u0026amp; Compatibility\u003c\/h3\u003e\n\n\u003cp\u003eDesigned for Woodward easYgen-2500 genset control systems. Supports standalone emergency, isochronous parallel (up to 32 gensets), cogeneration, and utility paralleling applications. LogicsManager enables complex controls combining measured values, internal conditions, and I\/O states. Remote panel RP-3000 compatible. Multilingual graphical display supports global deployment.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1: What is the difference between 8440-1934 and other easYgen models?\u003c\/strong\u003e\u003cbr\u003e\nA1: 8440-1934 is the operator interface for easYgen-2500 breaker control. Plastic housing, front panel mount, 282×217×99 mm. Back panel version has sheet metal housing (250×228×84 mm).\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: How many gensets can be controlled?\u003c\/strong\u003e\u003cbr\u003e\nA2: Supports isochronous parallel operation of up to 32 gensets in island mode or paralleled to utility.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What communication protocols are supported?\u003c\/strong\u003e\u003cbr\u003e\nA3: Supports CAN open, J1939, Modbus RTU, and modem communication for SCADA and external I\/O integration.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":52581357650052,"sku":"8440-1934","price":271.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/8440-1934.jpg?v=1785585606"},{"product_id":"woodward-8200-1302-flex505-lvdc-controller-8-4-display","title":"Woodward 8200-1302 Flex505 LVDC Controller 8.4 Display","description":"\u003ch2 style=\"color: #005A9C;\"\u003e8200-1302 Woodward Flex505 Marine\/ATEX LVDC Controller\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong style=\"color: #005A9C;\"\u003e8200-1302\u003c\/strong\u003e is a Woodward Flex505 controller with Marine and ATEX compliance. Features 8.4\" graphical display (800x600), LVDC power 18-32 Vdc, isolated communications, and extensive I\/O. Operating range -30°C to +70°C.\u003c\/p\u003e\n\n\u003ch3\u003eCore Technical Advantages\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMarine\/ATEX Certified:\u003c\/strong\u003e Compliant for marine and hazardous area installations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e8.4\" Graphical Display:\u003c\/strong\u003e 800x600 resolution with keypad for local operation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Power Options:\u003c\/strong\u003e LVDC version 18-32 Vdc, isolated.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e4 Ethernet Ports:\u003c\/strong\u003e Isolated 10\/100 communication ports for network redundancy.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e4 CAN Ports:\u003c\/strong\u003e 1 Mbit isolated ports support RTCnet and LINKnet HT distributed I\/O.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWide I\/O Count:\u003c\/strong\u003e 2 speed sensors, 8 analog inputs, 6 analog outputs, 20 discrete inputs, 8 relay outputs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGAP Configurable:\u003c\/strong\u003e Update rates from 5 ms to 160 ms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003ctable style=\"width:100%; border-collapse: collapse; font-size:14px;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color:#f0f0f0;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003e8200-1302\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDescription\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eFlex505 Marine\/ATEX LVDC Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e18 - 32 Vdc, isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e8.4\" LCD, 800x600, with keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4 x 10\/100, isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCAN Ports\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4 x 1 Mbit, isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSerial Ports\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1x RS-232\/RS-485, 1x RS-232 Service\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eUpdate Rates\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e5 ms to 160 ms (GAP configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSpeed Sensor Inputs\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 (MPU\/Prox with Prox Power)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e8 x 4-20mA (with Loop Power)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e6 x 4-20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eActuator Outputs\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 (configurable 4-20mA \/ 20-200mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e20 (with Contact Power)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e8 x Form-C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e-30°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCertification\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMarine \/ ATEX\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation \u0026amp; Maintenance Guide\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Same installation\/mounting as current 505 product line. Front panel mounting.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Connect 18-32 Vdc isolated input. Ensure adequate capacity for full I\/O load.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommunications:\u003c\/strong\u003e Use shielded cables for Ethernet, CAN, and serial ports. Maintain proper isolation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eI\/O Configuration:\u003c\/strong\u003e GAP configurable update rates from 5 ms to 160 ms per application requirements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Operating range -30°C to +70°C with display. Marine and ATEX compliant installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eEngineering Advantages \u0026amp; Compatibility\u003c\/h3\u003e\n\n\u003cp\u003eSignificant upgrade to the existing 505 product line with enhanced CPU, graphical display, and I\/O. Supports expanded I\/O options using Woodward CAN distributed I\/O nodes (RTCnet and LINKnet HT). Ideal for marine, offshore, and hazardous area turbine\/genset control applications. 4 Ethernet ports enable network redundancy. 4 CAN ports support distributed I\/O expansion.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1: What is the difference between 8200-1302 and standard Flex505?\u003c\/strong\u003e\u003cbr\u003e\nA1: 8200-1302 is the LVDC version (18-32 Vdc) with Marine and ATEX compliance for hazardous area and marine installations.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: What distributed I\/O options are supported?\u003c\/strong\u003e\u003cbr\u003e\nA2: Supports Woodward RTCnet and LINKnet HT CAN distributed I\/O nodes for expanded I\/O capacity.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What update rates are configurable?\u003c\/strong\u003e\u003cbr\u003e\nA3: GAP configurable update rates from 5 ms to 160 ms, allowing optimization for different application speeds.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":52581389795460,"sku":"8200-1302","price":264.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/8200-1302_2.jpg?v=1785586870"},{"product_id":"woodward-8200-1301-505-turbine-control","title":"Woodward 8200-1301 505 Turbine Control","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color:#0066CC;\"\u003eWoodward 8200-1301 505\u003c\/strong\u003e is a digital control system for steam turbine governing. It accepts universal AC\/DC power (88–132 Vac or 90–150 Vdc) and delivers precise speed, load, and extraction control. Field‑proven for generator and mechanical‑drive turbines.\u003c\/p\u003e\n\n\u003ch2\u003eCore Advantages\u003c\/h2\u003e\n\u003ch3\u003eUniversal Power Supply\u003c\/h3\u003e\n\u003cp\u003eOperates from 88–132 Vac or 90–150 Vdc. No separate power conditioning required.\u003c\/p\u003e\n\n\u003ch3\u003eComplete Turbine Control\u003c\/h3\u003e\n\u003cp\u003eSpeed control, load control, extraction\/induction, and cascade control. Built‑in overspeed protection and start‑up sequencing.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; font-size:13px;\"\u003e\n  \u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"padding:5px; border:1px solid #ddd; text-align:left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding:5px; border:1px solid #ddd; text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eAC Supply\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003e88–132 Vac (47–63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eDC Supply\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003e90–150 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003e25 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003e4 × 4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eRTD Inputs\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003e2 × 100Ω Pt (3‑wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003e2 × 4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003e8 × 24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003e4 × Form C (5A)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eSpeed Sensor Input\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eMPU 0.5–20 Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eActuator Output\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003e4–20 mA or 0–200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eCommunication\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eRS‑232 \/ RS‑422 \/ RS‑485 (Modbus)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eLCD with keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003e-20 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eCE, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eDimensions (H×W×D)\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003e300 × 150 × 200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003e3.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation Tips\u003c\/h2\u003e\n\u003ch3\u003ePower \u0026amp; Wiring\u003c\/h3\u003e\n\u003cp\u003eConnect AC (88–132 Vac) or DC (90–150 Vdc). Proper grounding required. Speed sensor gap: 0.5–1.0 mm from gear tooth. Use shielded cables for sensor and communication lines.\u003c\/p\u003e\n\n\u003ch3\u003eActuator Setup\u003c\/h3\u003e\n\u003cp\u003eConfigure output as 4–20 mA or 0–200 mA to match your actuator. Select via software menu.\u003c\/p\u003e\n\n\u003ch2\u003eWhy Choose 8200-1301 505?\u003c\/h2\u003e\n\u003cp\u003eProven in thousands of steam turbine installations. Intuitive LCD keypad simplifies commissioning. Universal power supply supports global retrofits. Built‑in overspeed and extraction control reduce external hardware.\u003c\/p\u003e\n\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: 4–20 mA or 0–200 mA actuator output – which to choose?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e 4–20 mA for modern actuators. 0–200 mA for older electro‑hydraulic types. Configure via software.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Can I connect a 2‑wire 4–20 mA transmitter?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e Yes. The analog inputs provide internal loop power for 2‑wire transmitters.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What happens after power loss?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e All settings are retained in non‑volatile memory. Turbine remains safe until operator restarts.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":52583218872452,"sku":"8200-1301","price":264.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/Woodward8200-1301-1.jpg?v=1785668563"},{"product_id":"9905-760-woodward-digital-synchronizer-module","title":"9905-760 Woodward Digital Synchronizer Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color:#0066CC;\"\u003eWoodward 9905-760\u003c\/strong\u003e is a Digital Synchronizer and Load Control Module for multi‑generator power systems. It measures frequency and phase angle, provides precise synchronisation signals, and regulates load sharing to maintain stable voltage and frequency. Ideal for parallel generator operation in power generation and marine applications.\u003c\/p\u003e\n\n\u003ch2\u003eCore Advantages\u003c\/h2\u003e\n\u003ch3\u003ePrecise Digital Synchronisation\u003c\/h3\u003e\n\u003cp\u003eMicroprocessor‑based measurement of frequency and phase angle. Synchronises multiple generators before grid connection. Automatic or manual operation modes.\u003c\/p\u003e\n\n\u003ch3\u003eIntelligent Load Control\u003c\/h3\u003e\n\u003cp\u003eMonitors load demand and adjusts generator output. Prevents overloading and overheating. Enables efficient load sharing across parallel units.\u003c\/p\u003e\n\n\u003ch3\u003eCommunication Ready\u003c\/h3\u003e\n\u003cp\u003eSupports LinkNet termination resistor module with screw clamp terminals. Interfaces with other control systems for integrated power management.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; font-size:13px;\"\u003e\n  \u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"padding:5px; border:1px solid #ddd; text-align:left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding:5px; border:1px solid #ddd; text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003e9905-760\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eType\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eDigital Synchronizer + Load Control\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eSynchronisation\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eFrequency \u0026amp; phase angle measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eOperation Modes\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eAutomatic \/ Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eLoad Control\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eDemand‑based output regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eParallel Operation\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eMulti‑generator support\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eCommunication\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eLinkNet (termination resistor module)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eTerminals\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eScrew clamp type\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eCabinet Enclosure\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eSix‑sided metal (solid doors recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eRF Attenuation (door window)\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003e\u0026gt;20 dB (10 kHz–1 GHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eMax Cable Entry Aperture\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003e152 mm (6 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eBonding\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eCabinet frame \u0026amp; mounting areas grounded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation Tips\u003c\/h2\u003e\n\u003ch3\u003eCabinet Grounding\u003c\/h3\u003e\n\u003cp\u003eUse a six‑sided metal enclosure. Solid metal doors are preferred. If a window is required, ensure \u0026gt;20 dB RF attenuation from 10 kHz to 1 GHz.\u003c\/p\u003e\n\n\u003ch3\u003eCable Entry\u003c\/h3\u003e\n\u003cp\u003eLimit cable entry holes to 152 mm (6 inches) maximum aperture. This is critical when RF transmitters (handheld radios) are near cable access points.\u003c\/p\u003e\n\n\u003ch3\u003eBonding\u003c\/h3\u003e\n\u003cp\u003eBond the cabinet frame and all mounting areas together to ensure proper grounding and EMI protection.\u003c\/p\u003e\n\n\u003ch3\u003eLinkNet Wiring\u003c\/h3\u003e\n\u003cp\u003eUse the termination resistor module with screw clamp terminals for reliable communication network termination.\u003c\/p\u003e\n\n\u003ch2\u003eWhy Choose 9905-760?\u003c\/h2\u003e\n\u003cp\u003eDelivers precise generator synchronisation and load sharing in a single module. Microprocessor‑based control ensures accurate frequency matching. Automatic or manual modes provide operational flexibility. Robust cabinet grounding guidelines ensure reliable performance in EMI‑prone environments. Trusted by power plants and marine vessels worldwide.\u003c\/p\u003e\n\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the difference between automatic and manual modes?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e Automatic mode handles synchronisation and load sharing without operator intervention. Manual mode allows operator‑controlled adjustment via external signals.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Why is the 152 mm cable entry restriction important?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e Limits RF interference from handheld radios or transmitters near cable entry points. Prevents EMI coupling into control wiring.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Can this module synchronise more than two generators?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e Yes. The 9905-760 supports parallel operation of multiple generators in a power system.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":52583240466564,"sku":"9905-760","price":208.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/Woodward9905-760.jpg?v=1785669663"},{"product_id":"9905-204-woodward-dsm-synchronizer-module","title":"9905-204 Woodward DSM Synchronizer Module","description":"\u003ch2\u003e9905-204 Woodward DSM Synchronizer Module\u003c\/h2\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0055cc;\"\u003e9905-204\u003c\/strong\u003e Woodward DSM is a dedicated digital synchronizer for generator and turbine parallel operation. It delivers precise voltage matching (±1%) and phase-angle control, ensuring seamless bus coupling in 115\/230V-AC systems. Built for extreme environments, this module operates reliably from -35 to 65 °C.\u003c\/p\u003e\n\u003ch3\u003eCore Advantages\u003c\/h3\u003e\n\u003cp\u003eRugged 125V dc supply. Small sync window for rapid closure. Non-intrusive speed matching. Direct retrofit for 9900 series and legacy Woodward controls. LED status indicators for voltage, speed, and breaker commands.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e9905-204\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage\u003c\/td\u003e\n\u003ctd\u003e115\/230V-AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Supply\u003c\/td\u003e\n\u003ctd\u003e125 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Matching\u003c\/td\u003e\n\u003ctd\u003e±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSync Window\u003c\/td\u003e\n\u003ctd\u003eSmall (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 to 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Size\u003c\/td\u003e\n\u003ctd\u003e33.0 x 17.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Depth\u003c\/td\u003e\n\u003ctd\u003e8.25 x 4.27 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Quick Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGap voltage:\u003c\/strong\u003e Set to 2.5 Vdc at speed input (terminals 5-6). \u003cstrong\u003eCable:\u003c\/strong\u003e Use shielded twisted pairs; min bend radius 50 mm. \u003cstrong\u003eGrounding:\u003c\/strong\u003e Follow local ex-proof codes for hazardous areas.\u003c\/p\u003e\n\u003ch3\u003eWhy Choose 9905-204\u003c\/h3\u003e\n\u003cp\u003eEngineered for high-vibration turbine decks. The small sync window reduces mechanical stress. ±1% voltage accuracy ensures stable load sharing. Fully compatible with 3300 series and older Woodward AVRs.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How to set the gap voltage?\u003c\/strong\u003e\u003cbr\u003eA1: Adjust trimmer until 2.5 Vdc is measured at terminals 5-6 with generator at rated speed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Retrofit for 3300 series?\u003c\/strong\u003e\u003cbr\u003eA2: Yes, it supports analog\/digital outputs for 3300, 2301A, and most AVRs via jumpers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What does small sync window do?\u003c\/strong\u003e\u003cbr\u003eA3: Narrows phase-angle tolerance (e.g., ±2°) for reduced mechanical stress and longer turbine life.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":52583257014404,"sku":"9905-204","price":354.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/9905-204-2.jpg?v=1785671260"},{"product_id":"8237-1600-protech-gii-woodward-overspeed-detection-4-20ma","title":"8237-1600 ProTech-GII Woodward | Overspeed Detection 4-20mA","description":"\u003ch2\u003e8237-1600 Woodward ProTech-GII Overspeed Protection System\u003c\/h2\u003e\n\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color:#0055cc;\"\u003e8237-1600\u003c\/strong\u003e Woodward ProTech-GII is a triple modular redundant overspeed protection system designed for steam, gas, and hydro turbines. This panel-mounted unit delivers reliable turbine shutdown when dangerous overspeed conditions occur. The 8237-1600 features independent trip relays, voted inputs, and dual high\/low voltage power options for maximum system integrity.\u003c\/p\u003e\n\n\u003ch3\u003eCore Advantages\u003c\/h3\u003e\n\u003cp\u003eTriple module design enables online repairs without system shutdown. Two-out-of-three voted architecture ensures failsafe operation. Integrated Modbus communications simplify system integration. MPU and acceleration detection provide comprehensive speed monitoring. Sulfur-resistant coating suits Class 3C2 environments.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e8237-1600\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e13 x 17.5 x 6.25 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eIP56 (dust and water resistant)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e2 High Voltage OR 1 High + 1 Low Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e10A @ 115 Vac, 20A @ 220 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e4.2 inch with 15 keys per module\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 °C at 95% humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +65 °C at 95% humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eLess than 23 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA speed readout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Quick Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Panel mount with backplane structure simplifies installation and module replacement. \u003cstrong\u003eEnvironment:\u003c\/strong\u003e IP56 rating requires proper panel sealing. \u003cstrong\u003eWiring:\u003c\/strong\u003e Follow IEC 60664-1 overvoltage protection standards. \u003cstrong\u003eTesting:\u003c\/strong\u003e Use internal generator for routine speed verification tests.\u003c\/p\u003e\n\n\u003ch3\u003eWhy Choose 8237-1600\u003c\/h3\u003e\n\u003cp\u003eEngineered for critical turbine safety applications. Triple modular redundancy allows hot-swap maintenance. 2oo3 voting eliminates single-point failures. Compatible with any turbine size regardless of power source. Proven IEC 721-3-3 compliance for international installations.\u003c\/p\u003e\n\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can the 8237-1600 be serviced while the turbine is running?\u003c\/strong\u003e\u003cbr\u003e\nA1: Yes. The triple module design allows removal and replacement of one module while the other two maintain protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What voting architecture does this model use?\u003c\/strong\u003e\u003cbr\u003e\nA2: Two-out-of-three (2oo3) voted architecture ensures reliable shutdown decisions even with one module fault.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What communication protocol is supported?\u003c\/strong\u003e\u003cbr\u003e\nA3: Modbus communications are standard for easy integration with plant DCS or SCADA systems.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":52583290437764,"sku":"8237-1600","price":319.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/8237-1600.jpg?v=1785674537"},{"product_id":"5437-1124-woodward-overspeed-device-0-100khz-input-range","title":"5437-1124 Woodward Overspeed Device | 0-100kHz Input Range","description":"\u003ch2\u003e5437-1124 Woodward Overspeed Protection Device\u003c\/h2\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0055cc;\"\u003e5437-1124\u003c\/strong\u003e Woodward overspeed protection device delivers reliable speed monitoring and shutdown for turbines and rotating machinery. This compact unit accepts MPU or proximity probe inputs up to 100 kHz, providing 4-20 mA proportional output and dual relay contacts for trip and alarm functions. Engineered for demanding industrial environments, the 5437-1124 operates from -40 to 85 °C.\u003c\/p\u003e\n\u003ch3\u003eCore Advantages\u003c\/h3\u003e\n\u003cp\u003eWide 24V dc supply range (18-32V). Dual independent setpoints for alarm and trip. Adjustable time delays from 0.1 to 10 seconds. LED status indicators for power, speed, and relay states. DIN-rail or panel mounting options. Reverse polarity and transient protection.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5437-1124\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24V dc (18-32V range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency Range\u003c\/td\u003e\n\u003ctd\u003e0 to 100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003eMPU or proximity probe (50 mV to 30V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA proportional to speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Contacts\u003c\/td\u003e\n\u003ctd\u003e2x SPDT, 2A @ 250V ac \/ 30V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetpoint Range\u003c\/td\u003e\n\u003ctd\u003e0 to 100% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Delay\u003c\/td\u003e\n\u003ctd\u003e0.1 to 10 seconds (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP65 (dust and water jet protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e90 x 22.5 x 114 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Quick Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded twisted pair for MPU input; keep separate from power cables. \u003cstrong\u003eGrounding:\u003c\/strong\u003e Single-point ground to avoid ground loops. \u003cstrong\u003eSetpoint adjustment:\u003c\/strong\u003e Use front-panel trimpots or remote potentiometer (1k to 10k ohm). \u003cstrong\u003eMounting:\u003c\/strong\u003e DIN-rail (35mm) or direct panel mount with M4 screws.\u003c\/p\u003e\n\u003ch3\u003eWhy Choose 5437-1124\u003c\/h3\u003e\n\u003cp\u003eCompact and cost-effective overspeed solution. Wide input frequency range supports most speed sensors. Independent trip and alarm relays enable tiered protection strategy. IP65 rating allows installation in washdown areas. Field-adjustable time delays prevent nuisance trips during transient overspeed events.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What sensor types are compatible with the 5437-1124?\u003c\/strong\u003e\u003cbr\u003eA1: Magnetic pickups (MPU) with 50 mV to 30V output, and proximity probes with NPN or PNP signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How do I set the trip point?\u003c\/strong\u003e\u003cbr\u003eA2: Use the front-panel Setpoint 1 and Setpoint 2 trimpots. Each scales from 0 to 100% of the configured full-scale frequency.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can the 4-20 mA output be scaled for different speed ranges?\u003c\/strong\u003e\u003cbr\u003eA3: Yes. Adjust the zero and span potentiometers to map the input frequency to any 4-20 mA range within 0-100 kHz.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":52583297548420,"sku":"5437-1124","price":364.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/5437-1124-2.jpg?v=1785675536"},{"product_id":"5466-1001-woodward-digital-controller-power-supply","title":"5466-1001 Woodward Digital Controller Power Supply","description":"\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold; width: 40%;\"\u003eManufacturer \/ Brand\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003eWoodward Inc.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003eMicroNet TMR \/ MicroNet Plus Digital Controllers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003ePart Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003e\u003cspan style=\"color: #0044cc; font-weight: bold;\"\u003e5466-1001\u003c\/span\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eModule Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003eDigital Controller Redundant Power Supply Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eOutput Power Rating\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003e24 VDC, 16 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eNetwork Isolation \u0026amp; Speed Sensing\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003e1000 Vrms (0-60 Hz) | 1 to 30 VAC Speed Sensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eStatus LED Indicators\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003e4 LEDs (OK, Input Fault, Overtemperature, Power Supply Fault)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003ePhysical Dimensions\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003eH 461 mm x W 265 mm x D 59 mm (Occupies 2 Chassis Slots)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003e0°C to +55°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003e22 kg (48 lbs) in chassis\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Woodward \u003cspan style=\"color: #0044cc; font-weight: bold;\"\u003e5466-1001\u003c\/span\u003e is a high-reliability Digital Controller Power Supply Module engineered for MicroNet TMR and MicroNet Plus systems. Delivering a 24 VDC, 16 A output rating, this 2-slot module features active current-sharing circuitry that balances electrical loads across redundant supplies to reduce thermal stress. Weighing 22 kg (48 lbs) in-chassis and equipped with four front panel health LEDs, it supports online hot-swapping during turbine and engine control operations.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eActive Current Load Sharing:\u003c\/strong\u003e Balances system load evenly across redundant modules to extend unit lifespan and reduce operating heat.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHot-Swappable Redundancy:\u003c\/strong\u003e Allows individual power supplies to be replaced without shutting down running control processes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComprehensive LED Diagnostics:\u003c\/strong\u003e Features four status LEDs monitoring normal operation, input faults, overtemperature, and power converter faults.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Network Isolation:\u003c\/strong\u003e Rated for 1000 Vrms network isolation and built for harsh industrial turbine environment applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation Essentials\u003c\/h2\u003e\n\u003cp\u003eAlign card edges, push into slots, disconnect input power first, and avoid ESD damage.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is 5466-1001's function?\u003c\/strong\u003e\u003cbr\u003e\nA1: 24VDC power supply for Woodward MicroNet systems.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: What is its size and weight?\u003c\/strong\u003e\u003cbr\u003e\nA2: Occupies 2 chassis slots, weighs 22 kg (48 lbs).\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Does it support redundant load sharing?\u003c\/strong\u003e\u003cbr\u003e\nA3: Yes, active current sharing balances load equally.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":52665218269316,"sku":"5466-1000","price":195.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/5466-1000-2.jpg?v=1787386780"},{"product_id":"woodward-5437-080-netcon-field-terminal-module-24v","title":"Woodward 5437-080 NetCon Field Terminal Module 24V","description":"\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold; width: 40%;\"\u003eManufacturer \/ Brand\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003eWoodward Inc.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003eNetCon 5400 Series Turbine Control Systems\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003ePart Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003e\u003cspan style=\"color: #0044cc; font-weight: bold;\"\u003e5437-080\u003c\/span\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003eNetCon Field Terminal Module (FTM) \/ Relay Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eConnector Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003eSubminiature D-Type 37-Pin Connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eInput \/ Relay Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003e24 VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eDisplay \u0026amp; Controls\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003e24-Character LED Display | Emergency Stop Button\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eMounting \u0026amp; Termination\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003e35 mm DIN Rail Mountable | Cage-Clamp Terminals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003ePhysical Dimensions\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003e14 in x 11 in x 4 in (355.6 mm x 279.4 mm x 101.6 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003eApprox. 2.5 kg (5.5 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Woodward \u003cspan style=\"color: #0044cc; font-weight: bold;\"\u003e5437-080\u003c\/span\u003e is a NetCon Field Terminal Module (FTM) designed for NetCon 5400 Series turbine control systems. Measuring 14 x 11 x 4 inches and weighing approximately 2.5 kg (5.5 lbs), this 24 VDC relay module connects field wiring directly to MicroNet and NetCon I\/O modules via a subminiature D-type 37-pin connector. It features cage-clamp terminal points, an integrated 24-character LED status display, an Emergency Stop button, EMI shielding, and 35 mm DIN rail mounting capability.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e37-Pin Connector \u0026amp; Cage-Clamp Terminals:\u003c\/strong\u003e Enables secure connection between front I\/O modules and external field control wiring.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Emergency Stop \u0026amp; Display:\u003c\/strong\u003e Built-in Emergency Stop button and 24-character LED display for local monitoring and safety control.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecision Relay Switching:\u003c\/strong\u003e Interfacing low-voltage control electronics with higher-power external electrical circuits safely.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEMI \u0026amp; Shielding Protection:\u003c\/strong\u003e Designed to provide reliable noise rejection, shield termination, and robust signal integrity in industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation Essentials\u003c\/h2\u003e\n\u003cp\u003eSnap onto 35 mm DIN rail. Secure 37-pin cable, terminate field wiring, and ensure grounding.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is 5437-080's function?\u003c\/strong\u003e\u003cbr\u003e\nA1: 24VDC NetCon relay field terminal module with 37-pin plug.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: What is its size and weight?\u003c\/strong\u003e\u003cbr\u003e\nA2: Dimensions 14x11x4 in, weighs approx. 2.5 kg (5.5 lbs).\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: How is field wiring terminated?\u003c\/strong\u003e\u003cbr\u003e\nA3: Connects via cage-clamp blocks and 37-pin D-sub connectors.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":52665498501252,"sku":"5437-080","price":196.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/5437-080-2.jpg?v=1787399466"},{"product_id":"5437-079-woodward-netcon-duplex-field-terminal-module","title":"5437-079 Woodward | NetCon Duplex Field Terminal Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #003366;\"\u003eWoodward 5437-079\u003c\/strong\u003e is a high-reliability NetCon Duplex Field Terminal Module (FTM) engineered for critical prime mover control within Woodward MicroNet Plus and NetCon control architectures. Designed to facilitate seamless interconnectivity between control electronics and field relay modules, this FTM features a \u003cstrong\u003e37-pin sub-D connector configuration\u003c\/strong\u003e for robust control signal transmission. The 5437-079 delivers dependable load rejection performance, helping maintain system stability and rapid response during sudden load shed events or dynamic operating shifts. Constructed to withstand harsh industrial and marine environments, it meets stringent military-grade shock specifications (US MIL-STD-810C) and Lloyd’s register vibration standards across operating temperatures from 0°C to 55°C.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable border=\"1\" style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #003366; color: white;\"\u003e\n      \u003cth style=\"padding: 8px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background-color: #f0f9ff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eProduct Part Number\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003e\u003cstrong\u003e5437-079\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eManufacturer \/ Product Series\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eWoodward \/ NetCon \u0026amp; MicroNet Plus Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f0f9ff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eModule Type\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eNetCon Duplex Field Terminal Module (FTM)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eConnector Configuration\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003e37-Pin Connector (Multi-Relay Control Interface)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f0f9ff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003ePrimary Application Target\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003ePrime Mover Control, DLE Fuel Control, Relay Interfacing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eShock Resistance Standard\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eUS MIL-STD-810C Certified\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f0f9ff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eVibration Resistance Standard\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eLloyd’s ENV2 Test Qualified\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003e0°C to +55°C (32°F to +131°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f0f9ff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eApproximate Shipping Weight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003e\u003cstrong\u003e0.45 kg (1.0 lbs)\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eConstruction \u0026amp; Design\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eRugged Industrial Modular Terminal Base\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eKey Hardware \u0026amp; Operational Features\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e37-Pin Field Relay Interfacing:\u003c\/strong\u003e Dedicated multi-pin connection interface simplifies wiring routes to external relay banks while ensuring signal integrity for accurate switching execution.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Transient Load Rejection:\u003c\/strong\u003e Optimized for rapid-response turbines and prime movers, maintaining control stability during full or partial load rejection events.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMilitary \u0026amp; Marine Grade Durability:\u003c\/strong\u003e Engineered to withstand harsh industrial vibration and shock profiles according to US MIL-STD-810C and Lloyd’s ENV2 specifications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular System Compatibility:\u003c\/strong\u003e Seamlessly integrates with Woodward MicroNet Plus and NetCon control architectures, supporting advanced software algorithms like Dry Low Emissions (DLE) and incipient surge detection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation \u0026amp; Field Wiring Guidelines\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e1. Module Mounting:\u003c\/strong\u003e Secure the 5437-079 FTM onto the cabinet DIN rail or mounting panel near the target I\/O expansion racks.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e2. Cable Attachment:\u003c\/strong\u003e Connect the 37-pin field interface cable from the NetCon\/MicroNet controller to the matching header on the FTM, tightening securing screws to prevent loosening under vibration.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e3. Relay Wiring:\u003c\/strong\u003e Wire field devices and relay coils directly to the labeled terminal blocks according to the system channel assignment schematic.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1: What is the main function of the Woodward 5437-079 module?\u003c\/strong\u003e\u003cbr\u003e\nA1: It acts as a Field Terminal Module (FTM) to connect NetCon\/MicroNet control systems to field relay devices via a 37-pin connector.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: What industrial shock and vibration standards does this module meet?\u003c\/strong\u003e\u003cbr\u003e\nA2: It is tested and certified to US MIL-STD-810C for shock and Lloyd’s ENV2 for vibration resistance.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What control applications commonly use the 5437-079 FTM?\u003c\/strong\u003e\u003cbr\u003e\nA3: It is primarily used in prime mover controls, turbine load rejection management, naval propulsion, and DLE fuel control systems.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":52665503940740,"sku":"5437-079","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/5437-079.jpg?v=1787399984"},{"product_id":"9905-972-linknet-module-woodward-6-channel-analog-output","title":"9905-972 LinkNet Module | Woodward 6-Channel Analog Output","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #003366;\"\u003eWoodward LinkNet 9905-972\u003c\/strong\u003e is a high-reliability 6-Channel Analog Output (4–20 mA) I\/O Controller Node designed for distributed turbine and engine control architectures. As part of the Woodward LinkNet family, this module enables MicroNet and NetCon control systems to interface directly with field-actuated devices, control valves, positioners, and external indicators over standard 4–20 mA current loops. Operating as a networked I\/O node, the 9905-972 offloads signal-processing tasks, reduces field wiring complexity, and ensures fast, deterministic command execution. Built with a rugged enclosure for demanding industrial environments, the module features an approximate shipping weight of \u003cstrong\u003e0.45 kg (1.0 lbs)\u003c\/strong\u003e and delivers precise dynamic response across operating temperatures from 0°C to 55°C.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable border=\"1\" style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #003366; color: white;\"\u003e\n      \u003cth style=\"padding: 8px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background-color: #f0f9ff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eProduct Part Number\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003e\u003cstrong\u003e9905-972\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eManufacturer \/ Product Family\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eWoodward \/ LinkNet Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f0f9ff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eModule Type\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003e6-Channel Analog Output (4–20 mA) I\/O Controller Node\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eNumber of Output Channels\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003e6 Channels (Galvanically Isolated)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f0f9ff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eOutput Current Range\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003e4–20 mA Standard Current Loop\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eNetwork Communication Protocol\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eWoodward LinkNet High-Speed Network Bus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f0f9ff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003ePrimary Application Target\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eTurbine Control, Actuator Positioning, Valve Drive Signal Control\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eApproximate Module Weight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003e\u003cstrong\u003e0.45 kg (1.0 lbs)\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f0f9ff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eMounting Configuration\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eDIN Rail or Panel Mount Terminal Base\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003e0°C to +55°C (32°F to +131°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eKey Hardware \u0026amp; Operational Features\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDistributed I\/O Architecture:\u003c\/strong\u003e Mounts near field actuators to convert high-speed LinkNet serial bus commands into 6 accurate 4–20 mA current signals, drastically reducing long multi-pair wiring runs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Precision Actuator Control:\u003c\/strong\u003e Provides smooth, high-resolution current driving capabilities optimized for critical steam, gas, and hydro turbine control valves.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFault-Tolerant Network Integration:\u003c\/strong\u003e Fully compatible with Woodward MicroNet control systems, featuring automated node health reporting and loop fault detection.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Standard Compliance:\u003c\/strong\u003e Engineered with optical isolation and heavy-duty noise immunity to withstand harsh electromagnetic interference (EMI) typical in power generation sites.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation \u0026amp; Field Wiring Guidelines\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e1. Unit Mounting:\u003c\/strong\u003e Snap the LinkNet node onto a standard DIN rail inside the control cabinet or local field junction box.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e2. Network \u0026amp; Power Wiring:\u003c\/strong\u003e Connect the LinkNet network communication cable and power supply wires to the labeled terminal blocks on the module base.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e3. Channel Wiring:\u003c\/strong\u003e Wire external field devices (actuators, valves, positioners) to the 6 analog output channels using shielded twisted-pair 4–20 mA loop cables.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1: What is the main function of the Woodward 9905-972 node?\u003c\/strong\u003e\u003cbr\u003e\nA1: It acts as a distributed I\/O controller node converting LinkNet network commands into 6 isolated 4–20 mA analog outputs.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: What controllers are compatible with the LinkNet 9905-972?\u003c\/strong\u003e\u003cbr\u003e\nA2: It interfaces directly with Woodward MicroNet and NetCon control platforms over the LinkNet communications network.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What field devices can be driven by this module?\u003c\/strong\u003e\u003cbr\u003e\nA3: It is designed to drive 4–20 mA industrial actuators, electro-hydraulic valve positioners, variable frequency drive references, and remote meters.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":52674129952900,"sku":"9905-972","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/9905-972.jpg?v=1787386415"},{"product_id":"woodward-9905-971-discrete-input-module-24-channels","title":"Woodward 9905-971 Discrete Input Module | 24 Channels","description":"\u003ch2\u003eWoodward 9905-971 Technical Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eWoodward 9905-971\u003c\/strong\u003e is an industrial-grade Discrete Input Module designed by Woodward for critical control systems. Featuring a lightweight construction of approximately 0.45 kg (1.0 lbs), it accepts up to 24 contact inputs operating at 24 VDC wetting voltage with a fast 5 ms update time and 1 ms time-stamping resolution. Built with latent fault detection across its relay outputs, this module disengages safely via front-panel ejector handles and secures directly into the control chassis motherboard.\u003c\/p\u003e\n\n\u003ch2\u003ePart Number Breakdown\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e9905:\u003c\/strong\u003e Woodward Control Hardware \u0026amp; I\/O Module Series\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e-971:\u003c\/strong\u003e Specific Model Designator — 24-Channel 24 VDC Discrete Input Transducer Board\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 10px;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"text-align: left;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #ddd;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eManufacturer \/ Brand\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWoodward\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eFull Part Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003e9905-971\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDiscrete Input Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eNumber of Channels\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e24 Channels (4 Modules \/ 6 Contact Inputs per Module)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eDiscrete Input Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e24 VDC Nominal Contact Wetting Voltage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eExternal Power Options\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e18–32 VDC or 100–150 VDC External Source\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003ePerformance Resolution\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e5 ms Update Time \/ 1 ms Time Stamping Resolution\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eFault Detection System\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eLatent Fault Detection (Series-Parallel Relay Readback)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003ePhysical Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eApprox. 0.45 kg (1.0 lbs) Standard Module Weight\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eMounting \u0026amp; Hardware\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eChassis Card Guides \/ Motherboard Connectors with Top \u0026amp; Bottom Retaining Screws\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eCountry of Manufacture\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eUnited States (USA)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eKey Features \u0026amp; Hardware Configurations\u003c\/h2\u003e\n\u003cp\u003eFeatures 24 isolated inputs, 24VDC wetting, latent fault relay detection, 0.45 kg weight, 5ms update time, and USA origin.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What are the main specs of the Woodward 9905-971 module?\u003c\/strong\u003e\u003cbr\u003e\nA1: 24 discrete channels, 24 VDC input voltage, 5 ms update time, 1 ms time-stamping, and 0.45 kg weight.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: How does latent fault detection work on this module?\u003c\/strong\u003e\u003cbr\u003e\nA2: It uses a series-parallel relay configuration with readback circuitry to test relays without altering output state.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: How is contact wetting power provided to the discrete inputs?\u003c\/strong\u003e\u003cbr\u003e\nA3: Power can be sourced internally (via terminal jumpers 33–35) or externally via 18–32 VDC \/ 100–150 VDC.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":52730889764996,"sku":"9905-971","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/9905-971.jpg?v=1787981022"},{"product_id":"woodward-9905-969-4-20ma-6-channel-input-module","title":"Woodward 9905-969 4-20mA 6-Channel Input Module","description":"\u003ch2\u003eWoodward 9905-969 Technical Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eWoodward 9905-969\u003c\/strong\u003e is an industrial-grade LINKnet 6-Channel Analog Input Module (4-20mA) designed by Woodward for distributed I\/O integration within NetCon control system networks. Weighing 9.11 lbs with dimensions of 14W x 11H x 4D inches, it features a 2-line x 24-character display, 30 multi-function keypad, and 1% accuracy at 25°C. Housed in a Phoenix field termination package for DIN rail mounting, this module operates on 18–32 VDC power across harsh temperatures ranging from -40°C to +55°C.\u003c\/p\u003e\n\n\u003ch2\u003ePart Number Breakdown\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e9905:\u003c\/strong\u003e Woodward NetCon \u0026amp; LINKnet Control System Series\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e-969:\u003c\/strong\u003e Specific Model Designator — 6-Channel 4-20mA Analog Input Module\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications Table\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 10px;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"text-align: left;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #ddd;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eManufacturer \/ Brand\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWoodward\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eFull Part Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003e9905-969\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eProduct Type \u0026amp; Channels\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eLINKnet Analog Input Module \/ 6 Channels (4-20 mA)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eDisplay \u0026amp; Interface\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 Line x 24 Characters Display \/ 30 Multi-function Keypad\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003ePower Supply \u0026amp; Input Current\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e18 to 32 VDC Input Range \/ +24 VDC @ 1 A Nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eAccuracy \u0026amp; Isolation Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1% at 25 °C \/ 277 VAC Network to I\/O \/ 500 V Power to I\/O\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003ePhysical Weight \u0026amp; Dimensions\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e9.11 lbs (4.13 kg) \/ 14\" W x 11\" H x 4\" D\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eOperating Temperature \u0026amp; Mounting\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e-40 to +55 °C \/ Phoenix Field Termination DIN Rail Mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eUnited States (USA)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eKey Features \u0026amp; Hardware Configurations\u003c\/h2\u003e\n\u003cp\u003eFeatures 6-channel 4-20mA inputs, 24 VDC power, 9.11 lbs weight, display keypad, DIN mount, and USA origin.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What are the main specs of the Woodward 9905-969 module?\u003c\/strong\u003e\u003cbr\u003e\nA1: 6 analog channels (4-20mA), 24 VDC power, 1% accuracy, 9.11 lbs weight, and -40 to +55°C temperature range.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: How does the module connect to the NetCon network?\u003c\/strong\u003e\u003cbr\u003e\nA2: It connects via a single twisted pair wire to the NetCon controller trunk and uses two rotary switches to set node addresses (1–60).\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: How is the physical housing configured for installation?\u003c\/strong\u003e\u003cbr\u003e\nA3: Enclosed in a plastic Phoenix field termination package designed for convenient DIN rail mounting inside or near control cabinets.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":52730929184900,"sku":"9905-969","price":197.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/9905-969.jpg?v=1787981264"},{"product_id":"woodward-9905-860-peak-150-steam-turbine-control-24vdc-nema-4","title":"Woodward 9905-860 Peak 150 Steam Turbine Control 24VDC NEMA 4","description":"\u003ch2 style=\"color: #2c6e9e;\"\u003eWoodward 9905-860 Peak 150 Steam Turbine Digital Control\u003c\/h2\u003e\n\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong style=\"color:#2c6e9e;\"\u003eWoodward 9905-860\u003c\/strong\u003e is a Peak 150 steam turbine digital control. Compact budget control with Modbus communication and NEMA 4 enclosure. Designed for single valve rack or single valve steam turbines. Features 5 digit LED speed display and 6 LED status indicators. 24 V DC version. Control weight 3.2 kg.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px;\"\u003e\n\u003ctbody\u003e\n\u003cth style=\"padding:10px; border:1px solid #ccc; text-align:left; width:40%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding:10px; border:1px solid #ccc; text-align:left;\"\u003eValue\u003c\/th\u003e\n\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e9905-860\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003ePeak 150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eCommunications\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eModbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eNEMA 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eMagnetic Pickup Inputs\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e2 identical, high signal selected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e5 digit LED speed display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eLED Status Indicators\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e6 (remote speed, shutdown, MPU1, MPU2, CPU, overspeed test)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eFront Panel Keypad Switches\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e6 (raise lower speed, start, emergency trip, alarm reset, overspeed test)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e38 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e-25°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e483 x 310 x 105 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e3.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompact steam turbine digital control\u003c\/li\u003e\n\u003cli\u003eModbus communication for system integration\u003c\/li\u003e\n\u003cli\u003eNEMA 4 enclosure protects from water and dust\u003c\/li\u003e\n\u003cli\u003e2 identical high signal selected MPU inputs\u003c\/li\u003e\n\u003cli\u003e5 digit LED speed display for clear readout\u003c\/li\u003e\n\u003cli\u003e6 LED status indicators for system monitoring\u003c\/li\u003e\n\u003cli\u003e6 front panel keypad switches for operator control\u003c\/li\u003e\n\u003cli\u003eHandheld programmer setup prevents unwanted changes\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the power consumption and enclosure rating?\u003c\/strong\u003e\u003cbr\u003eA1: 38 W maximum power. NEMA 4 enclosure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What communication protocol does 9905-860 support?\u003c\/strong\u003e\u003cbr\u003eA2: Modbus communication.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What are the control dimensions and weight?\u003c\/strong\u003e\u003cbr\u003eA3: 483 x 310 x 105 mm. Weight 3.2 kg.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":52730988724356,"sku":"9905-860","price":163.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/9905-860.jpg?v=1787981444"}],"url":"https:\/\/www.etowonauto.com\/tk\/collections\/woodward.oembed?page=3","provider":"Etowon Auto","version":"1.0","type":"link"}