{"title":"HIMA","description":"\u003cp\u003eHIMA specializes in safety-related automation systems for high-risk industrial environments. This category covers HIMA safety controllers, I\/O modules, and system components used in emergency shutdown and safety logic applications. These solutions are trusted for compliance, reliability, and long-term system operation.\u003c\/p\u003e","products":[{"product_id":"16-channel-digital-input-module-f3236-hima","title":"16-Channel Digital Input Module F3236 HIMA","description":"\u003ch2\u003e\u003cstrong\u003eHIMA F3236 Input Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2e86ab;\"\u003eF3236\u003c\/strong\u003e from HIMA provides reliable input processing for mechanical contact signals in safety systems. This module handles 1-signal inputs with 24V mechanical contact ratings and features fast 8ms switching response times. The compact 4TE design offers efficient space utilization in control cabinet installations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eManufacturer:\u003c\/strong\u003e HIMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eProduct Number:\u003c\/strong\u003e F3236 (984323602)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eInput Signal Type:\u003c\/strong\u003e 1-signal input, Mechanical contact\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eInput Current:\u003c\/strong\u003e 6 mA (including cable plug)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eMechanical Contact Rating:\u003c\/strong\u003e 24 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eSpace Requirement:\u003c\/strong\u003e 4 TE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eOperating Data:\u003c\/strong\u003e 5 V DC: 120 mA, 24 V DC: 200 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eSwitching Time:\u003c\/strong\u003e ~8 ms (typical)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eWeight:\u003c\/strong\u003e 0.2 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Processing Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMechanical contact inputs support standard industrial switch devices\u003c\/li\u003e\n\u003cli\u003e6mA input current rating includes complete cable plug assembly\u003c\/li\u003e\n\u003cli\u003e24V contact rating ensures compatibility with common control voltages\u003c\/li\u003e\n\u003cli\u003eFast 8ms switching time enables quick system response to input changes\u003c\/li\u003e\n\u003cli\u003e1-signal input configuration simplifies wiring and maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompact 4TE footprint maximizes control panel space efficiency\u003c\/li\u003e\n\u003cli\u003eDual voltage operation (5V\/24V) supports flexible power configurations\u003c\/li\u003e\n\u003cli\u003eModerate power consumption minimizes overall system load requirements\u003c\/li\u003e\n\u003cli\u003eStandard HIMA mounting compatibility ensures easy installation\u003c\/li\u003e\n\u003cli\u003eRobust construction maintains reliability in industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat input types does this module accept?\u003c\/strong\u003e Mechanical contact inputs with 24V rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the typical response time?\u003c\/strong\u003e Approximately 8 milliseconds switching time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat are the power requirements?\u003c\/strong\u003e 5V DC at 120mA and 24V DC at 200mA.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":51050803527812,"sku":"F-3236","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/F3236_1.jpg?v=1764501468"},{"product_id":"hima-f-3334-2a-output-module-4te-width","title":"HIMA F 3334 2A Output Module 4TE Width","description":"\u003ch2\u003e\u003cstrong\u003eHIMA F3334 Safety Output Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2e86ab;\"\u003eF3334\u003c\/strong\u003e from HIMA delivers reliable 2A short-circuit proof output capability with comprehensive monitoring features. This safety output module provides robust performance with line break detection and undervoltage protection. With compact 4TE width and dual voltage operation, it offers flexible integration into various safety system configurations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eBrand:\u003c\/strong\u003e HIMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eModel:\u003c\/strong\u003e F3334\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eOutput Current:\u003c\/strong\u003e 2 A, short-circuit proof\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eInternal Voltage Drop:\u003c\/strong\u003e Max. 2 V at 2 A load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eLine Resistance:\u003c\/strong\u003e Max. 3.6 Ohms (in + out)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eUndervoltage Threshold:\u003c\/strong\u003e ≤ 16 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eShort-Circuit Current:\u003c\/strong\u003e 2.6 to 5 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eLine Break Detection:\u003c\/strong\u003e 0.5 to 9.5 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eOutput Leakage Current:\u003c\/strong\u003e Max. 550 µA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eReset Output Voltage:\u003c\/strong\u003e Max. 1.5 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eWatchdog Current:\u003c\/strong\u003e Max. 30 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eTest Signal Duration:\u003c\/strong\u003e Max. 250 µs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eSpace Requirement:\u003c\/strong\u003e 4 TE width\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eWeight:\u003c\/strong\u003e 0.25 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eOperating Data 5V DC:\u003c\/strong\u003e 130 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eOperating Data 24V DC:\u003c\/strong\u003e 130 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eProtection \u0026amp; Monitoring\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLine break detection activates between 0.5mA and 9.5mA current levels\u003c\/li\u003e\n\u003cli\u003eUndervoltage tripping at ≤16V protects against power supply issues\u003c\/li\u003e\n\u003cli\u003e3.6Ω maximum line resistance ensures proper circuit impedance\u003c\/li\u003e\n\u003cli\u003eWatchdog current monitoring up to 30mA maintains system integrity\u003c\/li\u003e\n\u003cli\u003eReset condition output voltage limited to 1.5V ensures safe state\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the maximum output current?\u003c\/strong\u003e 2A with short-circuit protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat line monitoring features are included?\u003c\/strong\u003e Line break detection and undervoltage protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat are the power requirements?\u003c\/strong\u003e 5V DC or 24V DC at 130mA current.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":51050803593348,"sku":"F3334","price":258.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/F3334-4.jpg?v=1764502023"},{"product_id":"hima-f7126-dc-dc-power-supply-module","title":"HIMA F7126 DC\/DC Power Supply Module","description":"\u003ch2\u003eHIMA F7126 DC\/DC Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #cc0000;\"\u003eHIMA F7126 Power Supply Module\u003c\/strong\u003e delivers reliable 5V DC power conversion from 24V DC sources, featuring high efficiency and robust protection for safety-critical industrial applications. This compact module ensures stable performance in demanding environments.\u003c\/p\u003e\n\u003ch3\u003eProduct Identification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e HIMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong style=\"color: #cc0000;\"\u003eF7126\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e DC\/DC Power Supply Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Space:\u003c\/strong\u003e 8 TE (40.3 mm width)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInput Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 24 V DC nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e -15% to +20% tolerance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary Fuse:\u003c\/strong\u003e 6.3 A time-delay protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Protection:\u003c\/strong\u003e Reverse polarity protected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOutput Performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 5 V DC ±0.5 V adjustable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory Setting:\u003c\/strong\u003e 5.4 V DC ±0.025 V preset\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Current:\u003c\/strong\u003e 10 A continuous output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Limiting:\u003c\/strong\u003e Approximately 13 A maximum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProtection Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Circuit Protection:\u003c\/strong\u003e Yes, automatic recovery\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage Protection:\u003c\/strong\u003e 6.5 V ±0.5 V threshold\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvercurrent Protection:\u003c\/strong\u003e Current limiting circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Protection:\u003c\/strong\u003e Over temperature shutdown\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency:\u003c\/strong\u003e ≥77% at full load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRipple \u0026amp; Noise:\u003c\/strong\u003e \u0026lt;15% peak-to-peak\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Operation:\u003c\/strong\u003e ≤0.025 V voltage difference\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Immunity:\u003c\/strong\u003e VDE 0871\/0877 Class B compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.2 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 40.3 mm width (8 TE standard)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFront Panel:\u003c\/strong\u003e Test socket and adjustment potentiometer\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling:\u003c\/strong\u003e Natural convection cooling\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Operation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Standard DIN rail installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Screw terminal connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustment:\u003c\/strong\u003e Front panel fine-tune potentiometer\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring:\u003c\/strong\u003e Test socket for voltage verification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCertifications \u0026amp; Warranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVDE 0871\/0877 Class B compliant\u003c\/li\u003e\n\u003cli\u003eCE marked for European market\u003c\/li\u003e\n\u003cli\u003eIndustrial safety standards\u003c\/li\u003e\n\u003cli\u003e\u003cstrong style=\"color: #188038;\"\u003e1-Year Manufacturer Warranty\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackage Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHIMA F7126 Power Supply Module\u003c\/li\u003e\n\u003cli\u003eInstallation manual\u003c\/li\u003e\n\u003cli\u003eMounting accessories\u003c\/li\u003e\n\u003cli\u003eTechnical specification sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Examples\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety System Applications:\u003c\/strong\u003e The \u003cstrong\u003eHIMA F7126 Power Supply Module\u003c\/strong\u003e provides reliable 5V DC power for safety PLCs, emergency shutdown systems, and safety instrumentation in process industries, ensuring uninterrupted operation in critical safety applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the input voltage range?\u003c\/strong\u003e\u003cbr\u003eIt accepts 24V DC with -15% to +20% tolerance range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the maximum output current?\u003c\/strong\u003e\u003cbr\u003eIt delivers up to 10A continuous current at 5V DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan the output voltage be adjusted?\u003c\/strong\u003e\u003cbr\u003eYes, via the front panel potentiometer from 4.5V to 5.5V DC.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":51050803626116,"sku":"F7126","price":205.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/F7126-6.jpg?v=1760852662"},{"product_id":"vr-h4135-hima-safety-relay-24vdc-sil-3","title":"VR-H4135 HIMA - Safety Relay 24VDC SIL 3","description":"\u003ch2\u003e\u003cstrong\u003eHIMA VR-H4135 Safety Relay Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2e86ab;\"\u003eVR-H4135\u003c\/strong\u003e from HIMA delivers reliable safety circuit control with SIL 3 certification according to IEC 61508 standards. This safety relay operates with 24VDC input voltage and features three output contacts for flexible safety system integration. With fast 30ms response time and robust construction, it ensures dependable performance in demanding industrial safety applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eBrand:\u003c\/strong\u003e HIMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eModel:\u003c\/strong\u003e VR-H4135\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eInput Voltage:\u003c\/strong\u003e 24 VDC ±20%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003ePower Consumption:\u003c\/strong\u003e Typically 2W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eSafety Level:\u003c\/strong\u003e SIL 3 (IEC 61508)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eContact Rating:\u003c\/strong\u003e 5A at 250VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eOutput Configuration:\u003c\/strong\u003e 2 NO, 1 NC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eResponse Time:\u003c\/strong\u003e Typically 30 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eHousing Material:\u003c\/strong\u003e Flame retardant plastic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eMounting Type:\u003c\/strong\u003e DIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eDimensions:\u003c\/strong\u003e 90mm x 22.5mm x 114mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eWeight:\u003c\/strong\u003e Approx. 100g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eCertifications:\u003c\/strong\u003e CE, UL listed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSafety Performance Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSIL 3 certification ensures compliance with highest safety integrity levels\u003c\/li\u003e\n\u003cli\u003eDual normally-open contacts provide redundant safety circuit control\u003c\/li\u003e\n\u003cli\u003eSingle normally-closed contact offers additional monitoring capability\u003c\/li\u003e\n\u003cli\u003eFast 30ms response time quickly activates safety functions when needed\u003c\/li\u003e\n\u003cli\u003eComprehensive testing validates reliable operation in fault conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat safety certification does this relay have?\u003c\/strong\u003e SIL 3 according to IEC 61508 standard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many contacts are provided?\u003c\/strong\u003e Two normally-open and one normally-closed contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the maximum switching current?\u003c\/strong\u003e 5A at 250VAC rating.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":51050817192068,"sku":"VR-H4135","price":165.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/VR-H4135_1140ad44-932f-4d81-befa-55a3cf1569f0.jpg?v=1764501545"},{"product_id":"hima-f-8650e-safety-system-module-25mhz-cpu-module","title":"HIMA F 8650E Safety System Module | 25MHz CPU Module","description":"\u003ch2\u003e\u003cstrong\u003eHIMA F8650E Safety System Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2e86ab;\"\u003eF8650E\u003c\/strong\u003e from HIMA represents an advanced safety system module designed for critical industrial applications. This central module features two clock-synchronized microprocessors operating at 25 MHz frequency. The unit requires 24 VDC power and delivers reliable safety monitoring with comprehensive diagnostic capabilities.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eBrand:\u003c\/strong\u003e HIMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eModel:\u003c\/strong\u003e F8650E\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eModule Type:\u003c\/strong\u003e Safety System CPU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eClock Frequency:\u003c\/strong\u003e 25 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003ePower Supply:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eOutput Current:\u003c\/strong\u003e 500 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eMax Current:\u003c\/strong\u003e 2000 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eMicroprocessors:\u003c\/strong\u003e Dual Intel 386EX, 32-bit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eOperating System Memory:\u003c\/strong\u003e 1 MB Flash-EPROM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eUser Program Memory:\u003c\/strong\u003e 1 MB Flash-EPROM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eData Memory:\u003c\/strong\u003e 1 MB SRAM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eInterfaces:\u003c\/strong\u003e 2x RS485 with electrical isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eDisplay:\u003c\/strong\u003e Four-digit matrix diagnostic display\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eSpace Requirement:\u003c\/strong\u003e 8 SU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eOperating Data:\u003c\/strong\u003e 5V \/ 2A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSafety \u0026amp; Reliability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSafety-rated watchdog monitoring with 24V output capability\u003c\/li\u003e\n\u003cli\u003eShort-circuit proof output protects connected safety devices\u003c\/li\u003e\n\u003cli\u003e500 mA output capacity supports multiple safety peripherals\u003c\/li\u003e\n\u003cli\u003eEuropean standard PCB construction ensures industrial durability\u003c\/li\u003e\n\u003cli\u003eDedicated display PCB facilitates clear status monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat processors does this module use?\u003c\/strong\u003e Dual Intel 386EX 32-bit microprocessors at 25MHz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat communication interfaces are available?\u003c\/strong\u003e Two electrically isolated RS485 serial interfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat power supply is required?\u003c\/strong\u003e 24 VDC operation with 5V\/2A operating data.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":51351495770244,"sku":"F8650E","price":212.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/F8650X_1.jpg?v=1764496475"},{"product_id":"hima-f8650x-central-safety-module-sil-3-certified-system","title":"HIMA F8650X Central Safety Module | SIL 3 Certified System","description":"\u003ch2\u003e\u003cstrong\u003eHIMA F8650X Central Safety Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2e86ab;\"\u003eF8650X\u003c\/strong\u003e from HIMA serves as the central module for PES H51q safety systems, delivering SIL 3 certification according to IEC 61508 standards. This advanced safety controller features dual 32-bit Intel 386EX microprocessors synchronized at 25 MHz clock frequency, providing redundant processing for critical safety applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eBrand:\u003c\/strong\u003e HIMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eModel:\u003c\/strong\u003e F8650X\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eSafety Level:\u003c\/strong\u003e SIL 3 (IEC 61508)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eCompatible Systems:\u003c\/strong\u003e PES H51q-MS, -HS, -HRS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eProcessor:\u003c\/strong\u003e Dual Intel 386EX, 32-bit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eClock Frequency:\u003c\/strong\u003e 25 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eMemory Configuration:\u003c\/strong\u003e 1MB Flash-EPROM (OS), 1MB Flash-EPROM (User), 1MB SRAM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eCommunication:\u003c\/strong\u003e Dual RS485 with electrical isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eDiagnostic Display:\u003c\/strong\u003e Four-digit matrix with selectable information\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eWatchdog Output:\u003c\/strong\u003e 24V, 500mA, short-circuit proof\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eConstruction:\u003c\/strong\u003e Two European standard PCBs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eSpace Requirement:\u003c\/strong\u003e 8 SU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eOperating Data:\u003c\/strong\u003e 5V \/ 2A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication \u0026amp; Interfaces\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual electrically isolated RS485 serial interfaces ensure reliable data transmission\u003c\/li\u003e\n\u003cli\u003ePin-configurable RS485 connections support flexible network configurations\u003c\/li\u003e\n\u003cli\u003eCompatible with F8627X communication module for Ethernet network integration\u003c\/li\u003e\n\u003cli\u003eSupports PADT connection via ELOP II TCP and Modbus TCP protocols\u003c\/li\u003e\n\u003cli\u003eBackplane bus architecture enables seamless communication with expansion modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat safety certification does this module hold?\u003c\/strong\u003e Certified for SIL 3 applications according to IEC 61508.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat communication protocols are supported?\u003c\/strong\u003e Supports ELOP II TCP, safeethernet, and Modbus TCP via F8627X module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the battery replacement schedule?\u003c\/strong\u003e Recommended replacement after 6 years or when BATI warning appears.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":51351515857028,"sku":"F8650X","price":212.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/F8650X-4.jpg?v=1764499864"},{"product_id":"hima-f8627x-communication-module-fast-ethernet-modbus-tcp","title":"HIMA F8627X Communication Module Fast Ethernet Modbus TCP","description":"\u003ch2\u003e\u003cstrong\u003eHIMA F8627X Communication Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2e86ab;\"\u003eF8627X\u003c\/strong\u003e from HIMA provides advanced Fast Ethernet communication capabilities for safety systems. This communication module supports multiple industrial protocols including safeethernet, Modbus TCP, and OPC connectivity. It enables seamless Ethernet programming of CPUs using ELOP II and facilitates integration within modern industrial networks.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eBrand:\u003c\/strong\u003e HIMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eModel:\u003c\/strong\u003e F8627X\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eModule Type:\u003c\/strong\u003e Communication Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eNetwork Interface:\u003c\/strong\u003e 100 Base-T, RJ45\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eProtocol Support:\u003c\/strong\u003e safeethernet, Modbus-TCP, OPC DA\/A\u0026amp;E\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eCompatible CPUs:\u003c\/strong\u003e F8650X\/F8652X (safe), F8651X\/F8653X (non-safe)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eDimensions:\u003c\/strong\u003e 3 HU (133.35mm) x 4 WU (20.32mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eWeight:\u003c\/strong\u003e 0.2kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eMounting:\u003c\/strong\u003e 19-inch module for H41q\/H51q systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eConfiguration:\u003c\/strong\u003e Mono or redundant safe communication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eProtocol \u0026amp; Connectivity Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFast Ethernet connectivity enables high-speed data exchange between safety systems\u003c\/li\u003e\n\u003cli\u003eModbus-TCP slave functionality supports integration with SCADA and control systems\u003c\/li\u003e\n\u003cli\u003eOPC DA and Alarm \u0026amp; Event services via HIMA OPC server ensure data accessibility\u003c\/li\u003e\n\u003cli\u003eSafeethernet protocol maintains secure communication for critical safety data\u003c\/li\u003e\n\u003cli\u003eELOP II programming via Ethernet simplifies system configuration and updates\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat protocols does this module support?\u003c\/strong\u003e safeethernet, Modbus-TCP, OPC DA and OPC A\u0026amp;E.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhich CPU systems are compatible?\u003c\/strong\u003e Works with F8650X\/F8652X safety CPUs and F8651X\/F8653X non-safe CPUs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat are the physical dimensions?\u003c\/strong\u003e 3 height units x 4 width units for 19-inch rack mounting.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":51351516545156,"sku":"F8627X","price":229.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/F8627X-2.jpg?v=1764500145"},{"product_id":"hima-f8628x-communication-module-profibus-dp-slave","title":"HIMA F8628X Communication Module Profibus DP Slave","description":"\u003ch2\u003e\u003cstrong\u003eHIMA F8628X Communication Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2e86ab;\"\u003eF8628X\u003c\/strong\u003e from HIMA delivers robust Profibus DP slave communication for industrial safety systems. This advanced module enables ELOP II programming via Ethernet connections while maintaining reliable Profibus network integration. The dual interface design supports both traditional fieldbus and modern Ethernet connectivity requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eBrand:\u003c\/strong\u003e HIMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eModel:\u003c\/strong\u003e F8628X\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eModule Type:\u003c\/strong\u003e Communication Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003ePrimary Protocol:\u003c\/strong\u003e Profibus DP Slave\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eProgramming Interface:\u003c\/strong\u003e ELOP II via Ethernet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003ePhysical Interfaces:\u003c\/strong\u003e 9-pole SUB-D, 100Base-T RJ45\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eCompatible CPUs:\u003c\/strong\u003e F8650X\/F8652X (safe), F8651X\/F8653X (non-safe)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eDimensions:\u003c\/strong\u003e 3 HU (133.35mm) x 4 WU (20.32mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eWeight:\u003c\/strong\u003e 0.2 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eMounting:\u003c\/strong\u003e 19-inch module for H41q\/H51q systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIEC 61131-2 programmable controllers standard\u003c\/li\u003e\n\u003cli\u003eEN 61000 electromagnetic compatibility requirements\u003c\/li\u003e\n\u003cli\u003eIEEE 802.3 Ethernet networking standards\u003c\/li\u003e\n\u003cli\u003eEN 50170 Profibus fieldbus standards\u003c\/li\u003e\n\u003cli\u003eEN 50081-2\/EN 50082-2 EMC emission and immunity standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat protocol does this module support?\u003c\/strong\u003e Profibus DP slave protocol with Ethernet programming.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat interfaces are available?\u003c\/strong\u003e 9-pole SUB-D for Profibus and RJ45 for Ethernet connectivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhich systems use this module?\u003c\/strong\u003e Compatible with H41q\/H51q safety systems and new CPU versions.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":51351517331588,"sku":"F8628X","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/F8628X-4.jpg?v=1764500610"},{"product_id":"hima-f8621a-coprocessor-module-hd-64180-microprocessor","title":"HIMA F8621A Coprocessor Module HD 64180 Microprocessor","description":"\u003ch2\u003e\u003cstrong\u003eHIMA F8621A Coprocessor Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2e86ab;\"\u003eF8621A\u003c\/strong\u003e from HIMA serves as a dedicated coprocessor module for PES H51q safety systems. This module features an HD 64180 microprocessor operating at 10 MHz clock frequency and provides enhanced processing capabilities. It delivers robust communication functions and substantial memory resources for complex safety applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eBrand:\u003c\/strong\u003e HIMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eModel:\u003c\/strong\u003e F8621A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eModule Type:\u003c\/strong\u003e Coprocessor Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eMicroprocessor:\u003c\/strong\u003e HD 64180\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eClock Frequency:\u003c\/strong\u003e 10 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eMemory Capacity:\u003c\/strong\u003e 384 KB static memory (CMOS-RAM \u0026amp; EPROM)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eCommunication Interfaces:\u003c\/strong\u003e Dual RS485 with galvanic isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eBaud Rates:\u003c\/strong\u003e 300 to 57600 bps (software configurable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eAdditional Memory:\u003c\/strong\u003e Dual Port RAM for central module communication\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eSpace Requirement:\u003c\/strong\u003e 4 TE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eOperating Data:\u003c\/strong\u003e 5 V DC: 360 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eWeight:\u003c\/strong\u003e 0.2 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompact 4 TE space requirement optimizes control cabinet utilization\u003c\/li\u003e\n\u003cli\u003ePES H51q system compatibility ensures seamless safety system integration\u003c\/li\u003e\n\u003cli\u003ePower monitoring module F7131 support provides reliable battery backup\u003c\/li\u003e\n\u003cli\u003eLow power consumption (5V DC, 360mA) minimizes system load requirements\u003c\/li\u003e\n\u003cli\u003eMaster project RAM storage maintains critical system configuration data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat processor does this module use?\u003c\/strong\u003e HD 64180 microprocessor with 10 MHz clock frequency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat communication interfaces are available?\u003c\/strong\u003e Dual RS485 interfaces with galvanic isolation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat memory capacity does it provide?\u003c\/strong\u003e 384 KB static memory with battery backup support.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":51351517626500,"sku":"F8621A","price":258.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/F8621A_1.jpg?v=1764500842"},{"product_id":"hima-f-8652x-safety-cpu-intel-386ex-25mhz","title":"HIMA F 8652X Safety CPU Intel 386EX 25MHz","description":"\u003ch2\u003e\u003cstrong\u003eHIMA F8652X Safety-Related CPU Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2e86ab;\"\u003eF8652X\u003c\/strong\u003e from HIMA represents a high-performance safety CPU module designed for critical control applications. This central processing unit features dual Intel 386EX 32-bit microprocessors operating at 25 MHz clock frequency. The module delivers robust safety functionality with comprehensive diagnostic capabilities and reliable watchdog monitoring.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eBrand:\u003c\/strong\u003e HIMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eModel:\u003c\/strong\u003e F8652X\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003ePart Number:\u003c\/strong\u003e F8652X\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eModule Type:\u003c\/strong\u003e Safety-related CPU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eMicroprocessors:\u003c\/strong\u003e Dual Intel 386EX, 32-bit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eClock Frequency:\u003c\/strong\u003e 25 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eOperating System Memory:\u003c\/strong\u003e 1 MB Flash-EPROM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eUser Program Memory:\u003c\/strong\u003e 512 KB Flash-EPROM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eData Memory:\u003c\/strong\u003e 256 KB SRAM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eCommunication:\u003c\/strong\u003e 2x RS485 serial interfaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eWatchdog Output:\u003c\/strong\u003e 24V DC, 500mA, short-circuit proof\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eSpace Requirement:\u003c\/strong\u003e 8 TE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eOperating Data:\u003c\/strong\u003e 5V DC: 2000 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eWeight:\u003c\/strong\u003e 0.2 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eProcessing Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual Intel 386EX 32-bit processors provide redundant computing power\u003c\/li\u003e\n\u003cli\u003e25 MHz clock frequency ensures high-speed safety application execution\u003c\/li\u003e\n\u003cli\u003e1 MB Flash-EPROM stores operating system and critical firmware\u003c\/li\u003e\n\u003cli\u003e512 KB user program memory accommodates complex safety logic\u003c\/li\u003e\n\u003cli\u003e256 KB SRAM maintains real-time data for process monitoring\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat processors does this CPU use?\u003c\/strong\u003e Dual Intel 386EX 32-bit at 25MHz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat diagnostic features are available?\u003c\/strong\u003e Four-digit display, dual LEDs, and toggle switches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the battery life?\u003c\/strong\u003e 2500 days at 25°C with 4-year replacement recommendation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":51351517692036,"sku":"F8652X","price":264.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/F8652X_2_-removebg-preview.jpg?v=1764500930"},{"product_id":"hima-f-3237-8-fold-input-module-safety-related","title":"HIMA F 3237 8-Fold Input Module Safety Related","description":"\u003ch2\u003e\u003cstrong\u003eHIMA F3237 8-Fold Safety-Related Input Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2e86ab;\"\u003eF3237\u003c\/strong\u003e from HIMA provides eight safety-related input channels for industrial safety systems. This module connects safety-rated proximity switches, NAMUR sensors according to DIN 19234, and resistor-wired sensors. Comprehensive line monitoring continuously checks for short-circuits and wire breaks during operation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eBrand:\u003c\/strong\u003e HIMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eModel:\u003c\/strong\u003e F3237\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eModule Type:\u003c\/strong\u003e 8-Fold Input Module, Safety-Related\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eSafety Class:\u003c\/strong\u003e AK 1-6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eCompatible Sensors:\u003c\/strong\u003e NAMUR (DIN 19234), Proximity Switches, Resistor-wired\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eSwitching Time:\u003c\/strong\u003e ~10 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eOperating Current 0-Signal:\u003c\/strong\u003e 0.35 - 1.2 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eOperating Current 1-Signal:\u003c\/strong\u003e 2.1 - 6.0 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eWire Break Detection:\u003c\/strong\u003e ≤ 0.28 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eShort-Circuit Detection:\u003c\/strong\u003e ≥ 6.5 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eLine Impedance:\u003c\/strong\u003e ≤ 50 Ohm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eMax Line Length:\u003c\/strong\u003e 1000 m (0.5 mm²)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eSupply Voltage:\u003c\/strong\u003e 8.2 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eShunt Resistor:\u003c\/strong\u003e 681 Ohm, 1%, 0.25 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eSpace Requirement:\u003c\/strong\u003e 4 TE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eOperating Data:\u003c\/strong\u003e 5V DC: 90 mA; 24V DC: 170 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eWeight:\u003c\/strong\u003e 0.2 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSafety Monitoring Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous automatic testing verifies complete module functionality\u003c\/li\u003e\n\u003cli\u003eWalking 0 test prevents crosstalk between adjacent input circuits\u003c\/li\u003e\n\u003cli\u003eInput filter function monitoring ensures signal integrity\u003c\/li\u003e\n\u003cli\u003eShort-circuit detection triggers at currents exceeding 6.5 mA\u003c\/li\u003e\n\u003cli\u003eWire break detection activates when current drops below 0.28 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat sensors does this module support?\u003c\/strong\u003e NAMUR, proximity switches, and resistor-wired sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat safety features are included?\u003c\/strong\u003e Short-circuit, wire break detection, and continuous self-testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the maximum cable length?\u003c\/strong\u003e 1000 meters with 0.5 mm² wire diameter.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":51351517757572,"sku":"F3237","price":257.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/F3237-4.jpg?v=1764501265"},{"product_id":"hima-himatrix-f30-03-safety-controller","title":"HIMA HIMatrix F30 03 Safety Controller","description":"\u003ch2\u003e\u003cstrong\u003eHIMA HIMatrix F30 03 Safety-Related Controller\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2e86ab;\"\u003eHIMatrix F30 03\u003c\/strong\u003e from HIMA represents an advanced safety controller with comprehensive communication capabilities and robust performance. This safety-rated controller features 5MB program memory, fast 6ms response times, and multiple network interfaces for flexible system integration. With four Ethernet ports and three fieldbus interfaces, it supports complex safety applications in demanding industrial environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eBrand:\u003c\/strong\u003e HIMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eModel:\u003c\/strong\u003e HIMatrix F30 03\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eController Type:\u003c\/strong\u003e Safety-Related Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eTotal Memory:\u003c\/strong\u003e 5 MB (less 64 KB for CRCs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eResponse Time:\u003c\/strong\u003e ≥ 6 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eEthernet Interfaces:\u003c\/strong\u003e 4 x RJ-45, 10\/100BaseT with integrated switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eFieldbus Interfaces:\u003c\/strong\u003e 3 x 9-pole D-sub\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eOperating Voltage:\u003c\/strong\u003e 24 VDC, -15% to +20%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eCurrent Input:\u003c\/strong\u003e Max. 8 A (0.5 A idle)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eExternal Fuse:\u003c\/strong\u003e 10 A time-lag (T)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eDate\/Time Buffer:\u003c\/strong\u003e Gold capacitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eOperating Temperature:\u003c\/strong\u003e 0°C to +60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eProtection Rating:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eDimensions:\u003c\/strong\u003e 257mm x 114mm x 66mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eWeight:\u003c\/strong\u003e Approx. 1.2 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eProcessing Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e5MB total program and data memory handles complex safety applications\u003c\/li\u003e\n\u003cli\u003eFast 6ms minimum response time ensures quick safety function execution\u003c\/li\u003e\n\u003cli\u003eDedicated 64KB CRC memory maintains data integrity and verification\u003c\/li\u003e\n\u003cli\u003eRobust processing architecture supports multiple concurrent safety tasks\u003c\/li\u003e\n\u003cli\u003eEfficient memory management optimizes application program performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e24VDC operation with wide voltage tolerance ensures stable performance\u003c\/li\u003e\n\u003cli\u003eIP20 protection rating suits control cabinet installation requirements\u003c\/li\u003e\n\u003cli\u003e0°C to +60°C operating range covers most industrial environments\u003c\/li\u003e\n\u003cli\u003eExtended -40°C to +85°C storage temperature enables global deployment\u003c\/li\u003e\n\u003cli\u003eGold capacitor backup maintains date\/time during brief power outages\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat communication interfaces are available?\u003c\/strong\u003e 4 Ethernet ports and 3 fieldbus interfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the controller's response time?\u003c\/strong\u003e Minimum 6 milliseconds for safety functions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat are the physical dimensions?\u003c\/strong\u003e 257mm width x 114mm height x 66mm depth.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":51351518806148,"sku":"F3003","price":258.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/F3003_1.jpg?v=1764502354"},{"product_id":"hima-f3102-industrial-process-controller","title":"HIMA F3102 Industrial Process Controller","description":"\u003ch2\u003e\u003cstrong\u003eHIMA F3102 Process Control Unit\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2e86ab;\"\u003eF3102\u003c\/strong\u003e from HIMA serves as a reliable process control unit within the HIMatrix safety system. This industrial controller delivers robust performance with dedicated processing capabilities and multiple communication options. Designed for demanding process applications, it maintains reliable operation while supporting various fieldbus protocols and network configurations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eBrand:\u003c\/strong\u003e HIMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eModel:\u003c\/strong\u003e F3102\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eUnit Type:\u003c\/strong\u003e Process Control Unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eProgram Memory:\u003c\/strong\u003e 2.5 MB Flash\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eData Memory:\u003c\/strong\u003e 1 MB RAM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eScan Time:\u003c\/strong\u003e ≤ 8 ms typical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eEthernet Ports:\u003c\/strong\u003e 2 x 10\/100Base-TX, RJ45\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eFieldbus Support:\u003c\/strong\u003e PROFIBUS DP, Modbus TCP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003ePROFIBUS DP Rate:\u003c\/strong\u003e Up to 12 Mbps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eDigital Inputs:\u003c\/strong\u003e 16 channels, 24VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eDigital Outputs:\u003c\/strong\u003e 8 channels, 0.5A @ 24VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eAnalog Inputs:\u003c\/strong\u003e 4 channels, 0-10V \/ 4-20mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003ePower Supply:\u003c\/strong\u003e 24VDC ±25%, 15W max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eOperating Current:\u003c\/strong\u003e 650 mA @ 24VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eBackup Battery:\u003c\/strong\u003e Lithium, 3.6V, 5-year life\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eRelative Humidity:\u003c\/strong\u003e 5% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eVibration Resistance:\u003c\/strong\u003e 1g @ 10-150Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eShock Resistance:\u003c\/strong\u003e 15g, 11ms duration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eDimensions:\u003c\/strong\u003e 200mm x 100mm x 75mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eWeight:\u003c\/strong\u003e 0.2 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eCertifications:\u003c\/strong\u003e CE, cULus, ATEX Zone 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat fieldbus protocols are supported?\u003c\/strong\u003e PROFIBUS DP up to 12Mbps and Modbus TCP.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many I\/O channels are available?\u003c\/strong\u003e 16 DI, 8 DO, and 4 AI channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the operating temperature range?\u003c\/strong\u003e -20°C to +70°C for wide application use.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":51351519133828,"sku":"F3102","price":350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/F3102_3.jpg?v=1764502447"},{"product_id":"hima-f6217-analog-input-module-4-20ma-0-10v","title":"HIMA F6217 Analog Input Module 4-20mA 0-10V","description":"\u003ch2\u003e\u003cstrong\u003eHIMA F6217 8-Channel Analog Input Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2e86ab;\"\u003eF6217\u003c\/strong\u003e from HIMA provides eight safety-related analog input channels with SIL 3 certification according to IEC 61508. This module accepts both current (0\/4-20mA) and voltage (0-5\/10V) signals with safe isolation between channels. Featuring 12-bit resolution and fast 50ms update times, it delivers precise measurement for critical process safety applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eBrand:\u003c\/strong\u003e HIMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eModel:\u003c\/strong\u003e F6217\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eModule Type:\u003c\/strong\u003e 8-Channel Analog Input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eSafety Level:\u003c\/strong\u003e SIL 3 (IEC 61508)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eInput Signals:\u003c\/strong\u003e 0\/4-20mA, 0-5\/10V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eIsolation:\u003c\/strong\u003e Safe isolation between channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eResolution:\u003c\/strong\u003e 12 bits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eMax Input Voltage:\u003c\/strong\u003e 7.5V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eMax Input Current:\u003c\/strong\u003e 30 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eShunt Resistor:\u003c\/strong\u003e 250Ω, 0.05%, 0.25W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eInput Range:\u003c\/strong\u003e 0-5.5V (0=0, 5.5V=4095)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eUpdate Time:\u003c\/strong\u003e 50 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eSafety Time:\u003c\/strong\u003e \u0026lt;450 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eInput Resistance:\u003c\/strong\u003e 100 kΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eFilter Time Constant:\u003c\/strong\u003e ~10 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eBasic Error:\u003c\/strong\u003e 0.1% at 25°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eOperating Error:\u003c\/strong\u003e 0.3% at 0-60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eSafety Error Limit:\u003c\/strong\u003e 1%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eElectric Strength:\u003c\/strong\u003e 200V against GND\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eSpace Requirement:\u003c\/strong\u003e 4 SU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eOperating Data:\u003c\/strong\u003e 5VDC\/80mA, 24VDC\/50mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #a23b72;\"\u003eWeight:\u003c\/strong\u003e 0.3 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMeasurement Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e12-bit resolution provides 4095 counts across measurement ranges\u003c\/li\u003e\n\u003cli\u003eFast 50ms update time ensures real-time process monitoring\u003c\/li\u003e\n\u003cli\u003e0.1% basic accuracy at 25°C delivers precise measurement data\u003c\/li\u003e\n\u003cli\u003e0.3% operating error maintained across 0°C to 60°C temperature range\u003c\/li\u003e\n\u003cli\u003e10ms input filter time constant effectively suppresses noise\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSafety \u0026amp; Reliability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSIL 3 certification according to IEC 61508 for safety-critical applications\u003c\/li\u003e\n\u003cli\u003eSafe isolation between channels prevents cross-talk and interference\u003c\/li\u003e\n\u003cli\u003e1% safety error limit ensures reliable operation in fault conditions\u003c\/li\u003e\n\u003cli\u003e450ms maximum safety time guarantees timely safety function execution\u003c\/li\u003e\n\u003cli\u003e200V electric strength rating provides robust electrical protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSignal Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e4-20mA current input standard for process instrumentation\u003c\/li\u003e\n\u003cli\u003e0-10V voltage input support for various sensor types\u003c\/li\u003e\n\u003cli\u003e250Ω precision shunt resistor for current measurement\u003c\/li\u003e\n\u003cli\u003eHigh 100kΩ input resistance minimizes signal loading\u003c\/li\u003e\n\u003cli\u003e30mA maximum input current protection prevents damage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat signals does this module accept?\u003c\/strong\u003e 4-20mA current and 0-10V voltage inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the measurement update rate?\u003c\/strong\u003e 50ms update time with 450ms safety time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat safety certification does it have?\u003c\/strong\u003e SIL 3 according to IEC 61508 standard.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":51351519592580,"sku":"F6217","price":350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/F6217-3.jpg?v=1764503097"}],"url":"https:\/\/www.etowonauto.com\/tk\/collections\/hima.oembed","provider":"Etowon Auto","version":"1.0","type":"link"}