{"product_id":"ge-mdo54-369b1844g5005-24v-dc-100ma-output","title":"GE MDO54 369B1844G5005 24V DC 100mA Output","description":"\u003ch2\u003eGE MDO54 369B1844G5005 Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #1a5276;\"\u003eGE MDO54 369B1844G5005\u003c\/strong\u003e is a 16-channel digital output module designed for industrial control systems. Weighing approximately 0.7 kg, it provides 24V DC\/100mA outputs with high isolation ratings, offering reliable switching capability for interfacing with relay boards and field devices.\u003c\/p\u003e\n\u003ch3\u003eProduct Identification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e GE Nexus (General Electric)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e MDO54 \/ 369B1844G5005\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Digital Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e 16\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification:\u003c\/strong\u003e CE Certified (with system)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003cth style=\"padding: 8px 12px; border: 1px solid #ccc; text-align: left; width: 40%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 8px 12px; border: 1px solid #ccc; text-align: left; width: 60%;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eApprox. 0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eOutput Type\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e24V DC \/ 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eContact Capacity (Direct)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eN\/A (requires relay board)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eRelay Board Capacity\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e10A @ 220V DC (resistive), 16A @ 400V AC (resistive), 2A @ 220V DC (inductive), 3.6A @ 110V DC (inductive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eChannel-to-Channel Isolation\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e1000V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eChannel-to-Ground Isolation\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e2500V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eChannel-to-System Isolation\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e3000V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003ePower Consumption (Typical)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e1.3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003ePower Consumption (Max)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eLED Indicators\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eChannel Output LED indication per channel\u003c\/li\u003e\n\u003cli\u003eModule Run Status\u003c\/li\u003e\n\u003cli\u003eCommunication Status\u003c\/li\u003e\n\u003cli\u003eFault Alarm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 digital output channels for control applications.\u003c\/li\u003e\n\u003cli\u003eHigh isolation: 1000V AC channel-to-channel, 2500V AC channel-to-ground, 3000V AC channel-to-system.\u003c\/li\u003e\n\u003cli\u003eLED indication for output status, run, communication, and fault.\u003c\/li\u003e\n\u003cli\u003eLow power consumption: 1.3W typical, 4W maximum.\u003c\/li\u003e\n\u003cli\u003eCE certified for industrial compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall in Nexus system chassis.\u003c\/li\u003e\n\u003cli\u003eConnect outputs to external relay board for high-current switching.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding for isolation ratings.\u003c\/li\u003e\n\u003cli\u003eVerify output wiring within 24V DC\/100mA specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e How many output channels does the MDO54 have?\u003cbr\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e 16 digital output channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e What is the direct output capacity?\u003cbr\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e 24V DC \/ 100 mA per channel (requires external relay board for high-current loads).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e What isolation ratings does the module provide?\u003cbr\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e 1000V AC channel-to-channel, 2500V AC channel-to-ground, 3000V AC channel-to-system.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52710089031812,"sku":"MDO54","price":198.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/MDO54.jpg?v=1788098552","url":"https:\/\/www.etowonauto.com\/pt\/products\/ge-mdo54-369b1844g5005-24v-dc-100ma-output","provider":"Etowon Auto","version":"1.0","type":"link"}