{"product_id":"ge-ic697bem742-vme-integrator-rack-1-3a-controller-module","title":"Módulo Controlador GE IC697BEM742 VME Integrator Rack 1,3A","description":"\u003ch2 style=\"color: #003366; font-weight: bold; margin-bottom: 12px;\"\u003eVisão Geral do Produto\u003c\/h2\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333;\"\u003eO \u003cstrong style=\"color: #003366;\"\u003eIC697BEM742\u003c\/strong\u003e é um módulo controlador de barramento FIP (Factory Instrumentation Protocol) de slot único, projetado pela GE Fanuc para a plataforma PLC Série 90-70. Esta interface avançada conecta o rack integrador central IC697 PLC VME aos sistemas de barramento serial de E\/S FIP ou WorldFIP, gerenciando remotamente os módulos de E\/S Série 90-30 e módulos de controle de campo com precisão determinística.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 20px; margin-bottom: 12px;\"\u003ePrincipais Vantagens\u003c\/h2\u003e\n\u003cul style=\"font-size: 14px; line-height: 1.5; color: #333333; padding-left: 20px; margin-bottom: 15px;\"\u003e\n    \u003cli style=\"margin-bottom: 6px;\"\u003e\n\u003cstrong\u003eTopologia de Barramento Redundante:\u003c\/strong\u003e Conectores FIP duplos de 9 pinos transmitem sinais idênticos simultaneamente, proporcionando segurança robusta e redundante contra falhas.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 6px;\"\u003e\n\u003cstrong\u003eConfiguração de Software:\u003c\/strong\u003e Configuração digital completa via ferramentas de programação MS-DOS ou Windows elimina a necessidade de jumpers manuais ou interruptores DIP de hardware.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 6px;\"\u003e\n\u003cstrong\u003eComunicações Avançadas:\u003c\/strong\u003e Oferece mapeamento de pilha TCP\/IP de alto nível e capacidades genéricas de mensagens assíncronas junto com varreduras cíclicas regulares de E\/S.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 20px; margin-bottom: 12px;\"\u003eEspecificações Técnicas\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #003366; font-size: 14px; color: #333333;\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9; width: 35%;\"\u003eModelo \/ Número da Peça\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003eIC697BEM742\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eSérie do Sistema\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003eArquitetura PLC Série 90-70\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eProtocolo de Rede\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003eBarramento Serial de E\/S FIP \/ WorldFIP\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eTaxa de Velocidade de Dados\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e1 Megabit por segundo (1 Mbps)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eMemória a Bordo\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e2 MB de RAM e memória Flash de alta velocidade\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eTensão de Operação\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e5,0 Volts DC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eConsumo de Corrente no Backplane\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003eMáximo de 1,3 Ampères\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eConectores de Interface\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003eConectores Duplos de 9 Pinos para Barramento FIP | Porta Serial Única de 15 Pinos\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eIHM \u0026amp; Diagnóstico\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e6 Indicadores LED de Status + 1 Botão de Pressão no Painel Frontal\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003ePeso Líquido do Módulo\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e4,0 libras (aprox. 1,81 kg)\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 20px; margin-bottom: 12px;\"\u003eDicas Rápidas de Instalação\u003c\/h2\u003e\n\u003cul style=\"font-size: 14px; line-height: 1.5; color: #333333; padding-left: 20px; margin-bottom: 15px;\"\u003e\n    \u003cli style=\"margin-bottom: 6px;\"\u003eVerifique se a fonte de alimentação do rack VME do PLC IC697 pode fornecer a carga necessária de 1,3 Ampères pelo link de 5V DC do backplane.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 6px;\"\u003eUtilize a porta serial de 15 pinos exclusivamente para conectar uma estação de trabalho ou computador pessoal ao executar atualizações de firmware.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 6px;\"\u003eGaranta que os nós da rede de campo estejam totalmente mapeados no software utilitário MS-DOS ou Windows; o módulo não utiliza interruptores mecânicos.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 20px; margin-bottom: 12px;\"\u003ePerguntas Técnicas Frequentes\u003c\/h2\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 2px;\"\u003e\u003cstrong\u003eQ1: Como este módulo gerencia as atualizações de rastreamento de campo com a CPU principal?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #555555; margin-bottom: 10px;\"\u003eA1: O módulo escaneia dispositivos de E\/S assincronamente ao longo do barramento FIP, armazenando em buffer os dados de entrada, alarmes e falhas para transmiti-los à CPU central uma vez por ciclo de varredura do controlador.\u003c\/p\u003e\n\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 2px;\"\u003e\u003cstrong\u003eQ2: Qual é a finalidade do botão manual localizado no painel frontal?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #555555; margin-bottom: 10px;\"\u003eA2: Localizado logo abaixo da linha de 6 LEDs de diagnóstico, o botão de pressão de hardware facilita testes localizados do módulo, ciclo de status e reinicializações de falhas de hardware.\u003c\/p\u003e\n\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 2px;\"\u003e\u003cstrong\u003eQ3: As portas duplas de 9 pinos podem operar em sub-redes totalmente distintas e separadas?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #555555; margin-bottom: 10px;\"\u003eA3: Não. Os sinais internos roteados para ambas as portas de 9 pinos são totalmente idênticos, projetados estritamente para suportar redundância de mídia com cabo duplo para redes críticas.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050806968452,"sku":"IC697BEM742","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC697BEM742-1.jpg?v=1781534264","url":"https:\/\/www.etowonauto.com\/pt\/products\/ge-ic697bem742-vme-integrator-rack-1-3a-controller-module","provider":"Etowon Auto","version":"1.0","type":"link"}