{"product_id":"di880-24v-dc-digital-input-module-3bse028586r1-abb","title":"DI880 24V DC Digital Input Module | 3BSE028586R1 ABB","description":"\u003ch2\u003eABB DI880 Digital Input Module - Technical Specifications\u003c\/h2\u003e\n\u003ch3\u003eCore Product Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Designation:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003eDI880\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Identification:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e3BSE028586R1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Series:\u003c\/strong\u003e S800 I\/O System\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Weight:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e0.15 kg\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Specification:\u003c\/strong\u003e 24 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Certification:\u003c\/strong\u003e SIL3 IEC 61508, Category 4 EN 954-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Channel Count:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e16 channels\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e 18-30 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Voltage:\u003c\/strong\u003e 24 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e 7 mA per channel at 24V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogic \"0\" Level:\u003c\/strong\u003e -30 to +5 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogic \"1\" Level:\u003c\/strong\u003e 11 to 30 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e 3.1 kΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 2.4 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSafety and Redundancy Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Certification:\u003c\/strong\u003e SIL3 according to IEC 61508\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Category:\u003c\/strong\u003e Category 4 according to EN 954-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Support:\u003c\/strong\u003e Single or redundant configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Integrity:\u003c\/strong\u003e Yes, for safety applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Scheme:\u003c\/strong\u003e Groupwise isolated from ground\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSequence of Event Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSOE Functionality:\u003c\/strong\u003e Advanced event recording\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent Resolution:\u003c\/strong\u003e 1 ms precision\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent Accuracy:\u003c\/strong\u003e 0 ms to +1.3 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQueue Capacity:\u003c\/strong\u003e Up to 512 x 16 events\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent Reporting:\u003c\/strong\u003e Channel value, Queue full, Synchronization jitter, Uncertain time, Shutter filter active, Channel error\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePower Management\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransducer Power:\u003c\/strong\u003e One current-limited output per input channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModuleBus +5V:\u003c\/strong\u003e 125 mA typical, 150 mA maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal +24V:\u003c\/strong\u003e 15 mA + sensor power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Current:\u003c\/strong\u003e 527 mA total maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Supply:\u003c\/strong\u003e Current limited per channel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSignal Processing and Filtering\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Filters:\u003c\/strong\u003e 0-127 ms selectable range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShutter Filter:\u003c\/strong\u003e Unwanted event suppression\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Immunity:\u003c\/strong\u003e Programmable filtering\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 600 meters maximum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDiagnostics and Monitoring\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Diagnostics:\u003c\/strong\u003e On-board diagnostic features\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus LEDs:\u003c\/strong\u003e Fault, Run, Warning, Primary, Channel status\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Supervision:\u003c\/strong\u003e Process power monitoring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Monitoring:\u003c\/strong\u003e Comprehensive circuitry checks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eError Indication:\u003c\/strong\u003e Module Error, Module Warning, Internal channel error\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e45 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e102 mm\u003c\/strong\u003e (111 mm with connector)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e119 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e0.15 kg\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanics:\u003c\/strong\u003e S800 form factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental and Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0 to +55 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40 to +70 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Location:\u003c\/strong\u003e C1 Div 2 cULus, ATEX Zone 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Certificates:\u003c\/strong\u003e ABS, BV, DNV, LR\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e DIRECTIVE\/2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e IP20 according to IEC 60529\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible MTUs:\u003c\/strong\u003e TU810, TU812, TU814, TU818, TU830, TU833, TU842, TU843, TU852\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeying Code:\u003c\/strong\u003e FF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e S800 I\/O architecture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePrimary Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSafety instrumented systems (SIL3)\u003c\/li\u003e\n\u003cli\u003eCritical process safety applications\u003c\/li\u003e\n\u003cli\u003eHigh-reliability redundant systems\u003c\/li\u003e\n\u003cli\u003eSafety-related control systems\u003c\/li\u003e\n\u003cli\u003eProcess monitoring with safety requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Highlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSIL3 safety certification for critical applications\u003c\/li\u003e\n\u003cli\u003e16-channel design with individual sensor power\u003c\/li\u003e\n\u003cli\u003eAdvanced SOE with extensive event reporting\u003c\/li\u003e\n\u003cli\u003eRedundant configuration capability\u003c\/li\u003e\n\u003cli\u003eComprehensive safety diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat safety certifications does DI880 hold?\u003c\/h4\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2e86ab;\"\u003eDI880\u003c\/strong\u003e is \u003cstrong style=\"color: #2e86ab;\"\u003eSIL3 certified according to IEC 61508\u003c\/strong\u003e and \u003cstrong style=\"color: #2e86ab;\"\u003eCategory 4 according to EN 954-1\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003eHow does the transducer power distribution work?\u003c\/h4\u003e\n\u003cp\u003eProvides \u003cstrong style=\"color: #2e86ab;\"\u003eone current-limited transducer power output per input channel\u003c\/strong\u003e for individual sensor supply.\u003c\/p\u003e\n\u003ch4\u003eWhat is the SOE event capacity?\u003c\/h4\u003e\n\u003cp\u003eFeatures extensive event storage with capacity for \u003cstrong style=\"color: #2e86ab;\"\u003e512 x 16 events\u003c\/strong\u003e and comprehensive event status reporting.\u003c\/p\u003e\n\u003ch3\u003eContact Information\u003c\/h3\u003e\n\u003cp\u003eFor pricing information and technical support:\u003cbr\u003e\u003cstrong\u003eEmail: \u003c\/strong\u003e\u003ca href=\"mailto:sale@etowonauto.com\"\u003esale@etowonauto.com\u003c\/a\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51050795499652,"sku":"DI880","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/DI880.jpg?v=1763295466","url":"https:\/\/www.etowonauto.com\/pt\/products\/di880-24v-dc-digital-input-module-3bse028586r1-abb","provider":"Etowon Auto","version":"1.0","type":"link"}