{"product_id":"abb-di831-48v-dc-digital-input-module-3bse013212r1","title":"ABB DI831 48V DC Digital Input Module | 3BSE013212R1","description":"\u003ch2\u003eABB DI831 Digital Input Module - Technical Specifications\u003c\/h2\u003e\n\u003ch3\u003eCore Product Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Designation:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003eDI831\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Identification:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e3BSE013212R1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Series:\u003c\/strong\u003e S800 I\/O System\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Weight:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e0.22 kg\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Specification:\u003c\/strong\u003e 48 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Channel Count:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e16 channels\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e 36-60 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Voltage:\u003c\/strong\u003e 48 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e 4 mA per channel at 48V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogic \"0\" Level:\u003c\/strong\u003e -60 to +10 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogic \"1\" Level:\u003c\/strong\u003e 30 to 60 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e 9.6 kΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 3.2 W typical\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIsolation and Group Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Scheme:\u003c\/strong\u003e Groupwise isolated from ground\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGroup Configuration:\u003c\/strong\u003e 2 isolated groups of 8 channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Supervision:\u003c\/strong\u003e One monitoring input per group\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric Test:\u003c\/strong\u003e 500 V AC withstand voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Rating:\u003c\/strong\u003e 50 V rated voltage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSequence of Event Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSOE Functionality:\u003c\/strong\u003e Advanced event recording\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent Accuracy:\u003c\/strong\u003e -0.3 ms to +0.7 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent Resolution:\u003c\/strong\u003e 0.4 ms precision\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecording Capability:\u003c\/strong\u003e High-precision timing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSignal Processing and Filtering\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Filters:\u003c\/strong\u003e 0-100 ms selectable range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilter Function:\u003c\/strong\u003e Pulse width discrimination\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShutter Filter:\u003c\/strong\u003e Enhanced signal processing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 600 meters maximum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDiagnostics and Monitoring\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-Diagnostics:\u003c\/strong\u003e Cyclical automatic checking\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Power Supervision:\u003c\/strong\u003e Module failure on detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent Queue Monitoring:\u003c\/strong\u003e Full queue detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime Sync Monitoring:\u003c\/strong\u003e Missing synchronization detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus LEDs:\u003c\/strong\u003e Fault, Run, Warning, Channel status\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e45 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e102 mm\u003c\/strong\u003e (111 mm with connector)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e119 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e0.22 kg\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanics:\u003c\/strong\u003e S800 form factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePower Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModuleBus +5V:\u003c\/strong\u003e 100 mA typical, 120 mA maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModuleBus +24V:\u003c\/strong\u003e Not required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency:\u003c\/strong\u003e Optimized power management\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental and Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0 to +55 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40 to +70 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Location:\u003c\/strong\u003e C1 Div 2 cULus, ATEX Zone 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Certificates:\u003c\/strong\u003e ABS, BV, DNV, LR\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e DIRECTIVE\/2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e IP20 according to IEC 60529\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible MTUs:\u003c\/strong\u003e TU810, TU812, TU814, TU818, TU830, TU833, TU838, TU850\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeying Code:\u003c\/strong\u003e BD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e S800 I\/O architecture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePrimary Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial automation control systems\u003c\/li\u003e\n\u003cli\u003eHigh-voltage digital input applications\u003c\/li\u003e\n\u003cli\u003eProcess monitoring and control\u003c\/li\u003e\n\u003cli\u003eSequence of event recording systems\u003c\/li\u003e\n\u003cli\u003ePlant automation with 48V DC signals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Highlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16-channel high-density design for 48V DC applications\u003c\/li\u003e\n\u003cli\u003eDual isolated groups with individual voltage supervision\u003c\/li\u003e\n\u003cli\u003eAdvanced SOE functionality with 0.4ms resolution\u003c\/li\u003e\n\u003cli\u003eProgrammable digital filtering from 0-100ms\u003c\/li\u003e\n\u003cli\u003eComprehensive self-diagnostics and status monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat is the input voltage range for DI831?\u003c\/h4\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2e86ab;\"\u003eDI831\u003c\/strong\u003e operates with \u003cstrong style=\"color: #2e86ab;\"\u003e36-60V DC input signals\u003c\/strong\u003e at 48V nominal voltage.\u003c\/p\u003e\n\u003ch4\u003eHow are the input channels organized?\u003c\/h4\u003e\n\u003cp\u003eThis module features \u003cstrong style=\"color: #2e86ab;\"\u003e16 channels in two isolated groups of 8\u003c\/strong\u003e with voltage supervision.\u003c\/p\u003e\n\u003ch4\u003eWhat Sequence of Event capabilities are provided?\u003c\/h4\u003e\n\u003cp\u003eIncludes \u003cstrong style=\"color: #2e86ab;\"\u003eSOE recording with 0.4ms resolution\u003c\/strong\u003e and -0.3ms to +0.7ms accuracy.\u003c\/p\u003e\n\u003ch4\u003eWhat diagnostic features are available?\u003c\/h4\u003e\n\u003cp\u003eComprehensive diagnostics including \u003cstrong style=\"color: #2e86ab;\"\u003eprocess power supervision, event queue monitoring, and time synchronization checking\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eContact Information\u003c\/h3\u003e\n\u003cp\u003eFor pricing information and technical support:\u003cbr\u003e\u003cstrong\u003eEmail: \u003c\/strong\u003e\u003ca href=\"mailto:sale@etowonauto.com\"\u003esale@etowonauto.com\u003c\/a\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51050795434116,"sku":"3BSE013212R1","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/DI831.jpg?v=1763289549","url":"https:\/\/www.etowonauto.com\/pt\/products\/abb-di831-48v-dc-digital-input-module-3bse013212r1","provider":"Etowon Auto","version":"1.0","type":"link"}