{"product_id":"8440-1956-woodward-easygen-3000-engine-generator-control-module","title":"8440-1956 Woodward easYgen 3000 Engine Generator Control Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003e8440-1956\u003c\/strong\u003e (model designation: \u003cstrong\u003eeasYgen-3400-1-P1\u003c\/strong\u003e) is an engine generator controller engineered by Woodward Inc. as part of the easYgen-3000 series for complex breaker applications. Housed in a durable metal frame, this controller features a 1 A CT input, Accuracy Class 0.5 precision, and a multi-lingual display supporting 15 languages including English, German, Spanish, French, and Chinese. It provides comprehensive generator voltage monitoring (delta or wye configurations) with configurable A through F alarm classes. Weighing approximately 1.85 kg (4 lbs), the unit manages setting power ranges from 0.5 to 99,999.9 kW\/kvar in critical generator management systems.\u003c\/p\u003e\n\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecision Power \u0026amp; Voltage Monitoring:\u003c\/strong\u003e Delivers Accuracy Class 0.5 measurement with configurable wye\/delta voltage sensing to prevent earth faults.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMulti-Lingual User Interface:\u003c\/strong\u003e Built-in display support for 15 international languages simplifies field operation and diagnostics worldwide.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Alarm Management:\u003c\/strong\u003e Configurable alarm classes (A through F) allow precise threshold limit assignments and automated protective trip actions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eSpecification Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eBrand \u0026amp; Manufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eWoodward Inc.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eProduct Series Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eeasYgen-3000 Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e8440-1956\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eeasYgen-3400-1-P1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eApplication Field\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eEngine Generator Control (Complex Breaker Applications)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eCurrent Transformer (CT) Input\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e1 A CT Input\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eMeasurement Accuracy Class\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eClass 0.5\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eSetting Power Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0.5 to 99,999.9 kW \/ kvar\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eRelay Contact Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eAgCdO (Silver Cadmium Oxide)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eAlarm Configuration Classes\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eClasses A \/ B \/ C \/ D \/ E \/ F\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eDisplay Language Support\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eEnglish, German, Spanish, French, Italian, Portuguese, Japanese, Chinese, Russian, Turkish, Polish, Slovakian, Finnish, Swedish\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eEnclosure Construction\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eMetal Frame Enclosure\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eAmbient Operating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e95%, non-condensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eApprox. 1.85 kg (1,850 g \/ 4 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eIndustrial Applications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGenset Power Generation:\u003c\/strong\u003e Manages complex breaker operations and synchronization for diesel and gas engine generators.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eParalleling Control Systems:\u003c\/strong\u003e Coordinates load sharing and generator voltage\/frequency matching across utility grids.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEmergency Standby Power:\u003c\/strong\u003e Controls automatic transfer switches and utility protection in critical infrastructure facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWiring \u0026amp; Installation\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePanel Frame Inspection:\u003c\/strong\u003e Inspect metal housing for transit damage before mounting to prevent mechanical and frame grounding hazards.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage Sensing Setup:\u003c\/strong\u003e Wire generator voltage sensing in wye (phase-neutral) configuration for isolated networks to ensure earth-fault protection.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCT \u0026amp; Contact Connections:\u003c\/strong\u003e Connect 1 A current transformer secondary loops and AgCdO relay contact outputs to specified control terminals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact P1 Form Factor:\u003c\/strong\u003e Optimized panel footprint compared to P2 series modules while providing core generator control functionality.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Durability Contacts:\u003c\/strong\u003e AgCdO contact materials deliver reliable switching endurance under continuous duty cycles.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSolid Metal Housing:\u003c\/strong\u003e Structural metal frame provides EMI shielding and physical rigidity in generator enclosure panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What CT input rating does the Woodward 8440-1956 controller require?\u003c\/strong\u003e\u003cbr\u003e\nA1: The module is designed specifically for 1 A secondary current transformer (CT) input connections.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: How should voltage monitoring be configured for isolated networks?\u003c\/strong\u003e\u003cbr\u003e\nA2: Voltage monitoring must be configured as wye (phase-neutral) in isolated networks to prevent earth faults from causing false trip actions.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What power setting range is supported by the easYgen-3400-1-P1?\u003c\/strong\u003e\u003cbr\u003e\nA3: The controller supports a wide setting range from 0.5 to 99,999.9 kW\/kvar.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":67649771077764,"sku":"8440-1956","price":183.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/8440-1956.jpg?v=1791898760","url":"https:\/\/www.etowonauto.com\/pt\/products\/8440-1956-woodward-easygen-3000-engine-generator-control-module","provider":"Etowon Auto","version":"1.0","type":"link"}