{"product_id":"369b1841g5006-ge-nexus-analog-input-module-mai50-4-20ma","title":"369B1841G5006 GE Nexus Analog Input Module MAI50 4-20mA","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0066cc;\"\u003eGE 369B1841G5006\u003c\/strong\u003e Nexus Analog Input Module (MAI50) delivers 16 channels of high-precision analog signal acquisition. It supports 4-20mA and ±10V inputs, making it ideal for turbine and generator control systems. A powerful 32-bit processor ensures fast, accurate data conversion for critical monitoring applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cp\u003eThis module features a high-performance 32-bit embedded processor and communicates via a redundant high-speed serial bus at 1 Mbps. The DB-9 connector ensures reliable I\/O interfacing. Dual 24V DC power inputs provide 1:1 redundancy for maximum availability. It includes 16 single-ended analog input channels with 16-bit A\/D conversion, grouped in two banks of 8 channels each.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eModel\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e369B1841G5006 (MAI50)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eChannels\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e16 (single-ended)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eInput Signals\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e±10V, ±5V, 0(4)-20mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eA\/D Conversion\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e16-bit, 8 channels per group\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMeasurement Error\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMax 0.1%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Supply\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDual 24V DC ±10% (1:1 redundant)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Consumption\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eTypical 3W, Max 5W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIsolation Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1500VAC (system), 500VAC (channel to ground)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCMRR \/ NMRR\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u0026gt;120dB \/ \u0026gt;60dB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e209 x 129.5 x 51 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eApprox. 0.6 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0 to 60°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCertification\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCE (with system)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003cp\u003eMount the module using the provided screw terminals (2.5mm² wire capacity, dual-wire capable). Connect dual 24V DC power feeds for redundant operation. Use the DB-9 connector for serial bus communication. Ensure proper grounding and maintain cable segregation from high-voltage lines. Operate within 0-60°C temperature range and non-condensing humidity (10-90%).\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThis module offers high accuracy (0.1%) and robust isolation (1500VAC system isolation). The 16-bit resolution ensures precise signal measurement. Dual power inputs guarantee continuous operation in critical turbine control loops. With CMRR \u0026gt;120dB and NMRR \u0026gt;60dB, it effectively rejects electrical noise in harsh industrial environments.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What input ranges does the 369B1841G5006 support?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e This module accepts ±10V, ±5V, 4-20mA, and 0-20mA signals. Over-range alarm is supported for all ranges except ±10V input.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How is the analog input isolation configured?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e Channel-to-channel isolation is 250VAC, channel-to-ground is 500VAC, and system isolation is 1500VAC. This provides excellent protection in high-voltage environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What is the power redundancy scheme?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e The module features dual 24V DC (±10%) inputs with 1:1 redundancy. If one power source fails, the other automatically takes over without interrupting operation.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52700080373892,"sku":"369B1841G5006","price":187.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/369B1841G0131-1.jpg?v=1788091151","url":"https:\/\/www.etowonauto.com\/pt\/products\/369b1841g5006-ge-nexus-analog-input-module-mai50-4-20ma","provider":"Etowon Auto","version":"1.0","type":"link"}