{"product_id":"3500-15-03-03-01-bently-nevada-dual-dc-supply-1-39kg","title":"3500\/15-03-03-01 Bently Nevada Dual DC Supply 1.39kg","description":"\u003ch2 style=\"color: #333333;\"\u003eBently Nevada 3500\/15-03-03-01 Power Supply Module\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong style=\"color: #333333;\"\u003eBently Nevada 3500\/15-03-03-01\u003c\/strong\u003e is a power supply module for the 3500 monitoring system. Features High Voltage DC (88-140V DC) in top slot and High Voltage DC (88-140V DC) in bottom slot. CSA \/ NRTL \/ C Class 1 Division 2 approved. Weight: 1.39 kg (3.1 lbs).\u003c\/p\u003e\n\n\u003ch3 style=\"color: #333333;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px; border: 1px solid #333333;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e3500\/15-03-03-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003ePower Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eTop Slot Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eHigh Voltage DC (88-140V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eBottom Slot Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eHigh Voltage DC (88-140V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eAgency Approval\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eCSA \/ NRTL \/ C (Class 1 Division 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e-30°C to +65°C (-22°F to +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e120.7 × 50.8 × 251.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e1.39 kg (3.1 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #333333;\"\u003eConfiguration Breakdown\u003c\/h3\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px; border: 1px solid #333333;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eCode\u003c\/td\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eDescription\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003e03\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eHigh Voltage DC (88-140V DC) - Top Slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003e03\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eHigh Voltage DC (88-140V DC) - Bottom Slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003e01\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eCSA \/ NRTL \/ C (Class 1 Division 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #333333;\"\u003eKey Features\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eDual high-voltage DC power supplies for redundant operation\u003c\/li\u003e\n\u003cli\u003eCSA \/ NRTL \/ C Class 1 Division 2 certified for hazardous areas\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range -30°C to +65°C\u003c\/li\u003e\n\u003cli\u003eProvides regulated power to 3500 monitoring system rack\u003c\/li\u003e\n\u003cli\u003eCompact form factor for standard 3500 rack installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #333333;\"\u003eInstallation Guidelines (Field Engineer Notes)\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eSlot Placement:\u003c\/strong\u003e Top and bottom slots both require High Voltage DC supplies. Ensure both modules are properly seated and locked.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e Use 14 AWG minimum for DC input wiring. Connect positive to L1 and negative to L2. Torque terminals to 0.8 N·m (7 in·lb). Connect earth ground to chassis ground lug before energizing.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eVoltage Verification:\u003c\/strong\u003e Measure incoming DC at the terminal block before inserting modules. Verify 88-140V DC between L1 and L2. Polarity must be correct.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eRedundancy:\u003c\/strong\u003e Dual supplies provide hot-standby redundancy. If one supply fails, the second continues powering the rack without interruption.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFuse Check:\u003c\/strong\u003e Each supply has internal fuses. Before replacing a module, check AC\/DC input and fuse condition on the front panel.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #333333;\"\u003eFAQs\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1. Can I mix AC and DC supplies in this configuration?\u003c\/strong\u003e\u003cbr\u003e\nA1. No. This configuration uses High Voltage DC in both slots. Mixing AC and DC supplies requires a different part number with appropriate slot codes.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2. What is the maximum rack load for dual DC supplies?\u003c\/strong\u003e\u003cbr\u003e\nA2. Each DC supply provides 2.5A maximum. Dual supplies share the load. Total rack current should not exceed 5A.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3. How do I test redundancy operation?\u003c\/strong\u003e\u003cbr\u003e\nA3. Remove one supply while the rack is running. The second supply should maintain power with no interruption. Green LED on the remaining supply stays lit. Replace the removed supply within 30 seconds.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #333333;\"\u003eDownload\u003c\/h3\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/3500-15.pdf?v=1740032258\" style=\"color: #333333; text-decoration: none; font-weight: bold;\" target=\"_blank\"\u003eAccess Detailed Product Specifications PDF\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050450714756,"sku":"3500\/15-03-03-01","price":197.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_15-03-03-01-2.jpg?v=1783749299","url":"https:\/\/www.etowonauto.com\/pt\/products\/3500-15-03-03-01-bently-nevada-dual-dc-supply-1-39kg","provider":"Etowon Auto","version":"1.0","type":"link"}