{"product_id":"slc-5-03-5-04-pc-interface-cable-1747-cp3-allen-bradley","title":"SLC 5\/03 5\/04 PC Interface Cable 1747-CP3 Allen-Bradley","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eAllen-Bradley 1747-CP3\u003c\/strong\u003e is a 3-meter (118 inches \/ 9.8 feet) serial programming cable designed for the SLC 500 modular controller system by Rockwell Automation. Functioning as a 9-pin D-sub to 9-pin D-sub null modem cable, it establishes a direct RS-232 communication bridge between a host computer (DTE) and SLC 5\/03, 5\/04, or 5\/05 processor communication ports.\u003c\/p\u003e\n\n\u003cp\u003eEngineered with internal cross-over jumpers on both ends for hardware handshaking, the \u003cstrong style=\"color: #0056b3;\"\u003e1747-CP3\u003c\/strong\u003e is also fully compatible with PanelView component operator terminals and select MicroLogix controllers. Weighing approximately \u003cstrong\u003e0.17 kg (0.37 lbs)\u003c\/strong\u003e, this industrial-grade cable complies with European EMC Directives (EN 50081-2 and EN 50082-2) for reliable signal transmission in high-noise factory environments.\u003c\/p\u003e\n\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect RS-232 PC-to-PLC Connection:\u003c\/strong\u003e Eliminates the need for custom serial wiring by offering a pre-molded, 9-pin female DB9 to 9-pin female DB9 null modem pinout.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBroad Controller Compatibility:\u003c\/strong\u003e Seamlessly interfaces host PCs running RSLogix 500 with SLC 5\/03, 5\/04, and 5\/05 processors, as well as PanelView HMI terminals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Noise Immunity:\u003c\/strong\u003e Manufactured to withstand electromagnetic interference (EMC) in harsh industrial setups per EN 50081-2 and EN 50082-2 generic standards.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Handshake Jumpers:\u003c\/strong\u003e Built-in internal jumpers ensure immediate RS-232 hardware handshaking without requiring external adapter blocks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eSpecification Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eBrand \/ Manufacturer\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eCatalog Part Number\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e1747-CP3\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eSLC 500 System Accessories\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eComponent Type\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eRS-232 Null Modem Programming Cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eCable Length\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e3 meters (118 inches \/ 9.8 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eConnector Type\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e9-Pin D-Shell Female to 9-Pin D-Shell Female (DB9)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eCommunication Protocol\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eRS-232 Serial (DF1 \/ DH-485 point-to-point)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eCompatible Hardware\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eSLC 5\/03, SLC 5\/04, SLC 5\/05, MicroLogix, PanelView Terminals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0°C to 60°C (32°F to 140°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eEMC Compliance Standards\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e89\/336\/EEC, EN 50081-2 (Emission), EN 50082-2 (Immunity)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003ePhysical Dimensions\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e5.72 x 1.37 x 5.15 inches (Packaged)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eApproximate Net Weight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0.17 kg (0.37 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation \u0026amp; Handling Guidelines\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePort Pin Protection:\u003c\/strong\u003e Ensure the host computer and PLC RS-232 port thumb screws are properly secured to avoid intermittent serial communication drops during programming.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUSB Converter Usage:\u003c\/strong\u003e When connecting to modern laptops lacking physical serial ports, use a high-quality USB-to-RS232 converter (e.g., 9300-USBCBS) along with the 1747-CP3 cable.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eESD Precautions:\u003c\/strong\u003e Discharge static electricity prior to plugging the DB9 connector into sensitive communications ports to prevent transceiver damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Cable type?\u003c\/strong\u003e\u003cbr\u003e\nA1: 3-meter RS-232 DB9 null modem cable for SLC PLCs.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Compatible PLCs?\u003c\/strong\u003e\u003cbr\u003e\nA2: Connects PC to SLC 5\/03, 5\/04, 5\/05, and PanelView HMIs.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Length \u0026amp; ports?\u003c\/strong\u003e\u003cbr\u003e\nA3: 3 meters (118 in) long with 9-pin female DB9 ends.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52665069109380,"sku":"1747-CP3","price":179.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1747-CP3-2.jpg?v=1787750755","url":"https:\/\/www.etowonauto.com\/products\/slc-5-03-5-04-pc-interface-cable-1747-cp3-allen-bradley","provider":"Etowon Auto","version":"1.0","type":"link"}