{"product_id":"ic697mdl340-ge-intelligent-platforms-output-module-120v","title":"IC697MDL340 GE Intelligent Platforms Output Module 120V","description":"\u003ch2\u003eIC697MDL340 GE Fanuc Discrete Output Module – 16 Points 120VAC\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0066cc;\"\u003eGE Fanuc IC697MDL340\u003c\/strong\u003e is a 16-point discrete output module for the Series 90-70 PLC platform. Rated at 120 VAC. 16 output points divided into four isolated groups of four points each.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ctable width=\"100%\" border=\"0\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003eGE Intelligent Platforms \/ GE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003eSeries 90-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003eIC697MDL340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003eOutput Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e\u003cstrong\u003eIsolation Groups\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e4 (four points per group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e\u003cstrong\u003eDC Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e\u003cstrong\u003eAC Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e\u003cstrong\u003eLED Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003ctable width=\"100%\" border=\"0\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e85 to 132 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e\u003cstrong\u003eOutput Current Per Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e2 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e\u003cstrong\u003eOutput Current Per Group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e4 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e10x rated current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e\u003cstrong\u003eOn Response Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e1 ms max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e\u003cstrong\u003eOff Response Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e1\/2 cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e\u003cstrong\u003eLeakage Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e1.5 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePower Requirements\u003c\/h3\u003e\n\u003ctable width=\"100%\" border=\"0\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e\u003cstrong\u003e5V Bus Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e0.25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e\u003cstrong\u003eFuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd;\"\u003e10 A per group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 digital output points in 4 isolated groups of 4 points each\u003c\/li\u003e\n\u003cli\u003eRated 120 VAC, operating range 85 to 132 VAC\u003c\/li\u003e\n\u003cli\u003e2 Amps continuous per point, 4 Amps per group\u003c\/li\u003e\n\u003cli\u003e10x inrush current capacity for incandescent and inductive loads\u003c\/li\u003e\n\u003cli\u003eEach group separately fused with 10 Amp fuses\u003c\/li\u003e\n\u003cli\u003eLED indicators for point on\/off status and fuse status\u003c\/li\u003e\n\u003cli\u003eMechanical keying for correct module replacement\u003c\/li\u003e\n\u003cli\u003eConfiguration without jumpers or DIP switches\u003c\/li\u003e\n\u003cli\u003eCompatible with motor starters, solenoids, and indicators\u003c\/li\u003e\n\u003cli\u003eWorks with most Size 4 contactors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How many output points does the IC697MDL340 have?\u003c\/strong\u003e\u003cbr\u003eA1: 16 digital output points arranged in four isolated groups of four points each.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the maximum current per point and per group?\u003c\/strong\u003e\u003cbr\u003eA2: 2 Amps max per point, 4 Amps max per group. Each group is separately fused with a 10 Amp fuse.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What is the rated voltage and frequency?\u003c\/strong\u003e\u003cbr\u003eA3: 120 VAC rated voltage with operating range 85 to 132 VAC at 47 to 63 Hz.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050805493892,"sku":"IC697MDL340","price":196.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC697MDL340-GE.jpg?v=1782049225","url":"https:\/\/www.etowonauto.com\/products\/ic697mdl340-ge-intelligent-platforms-output-module-120v","provider":"Etowon Auto","version":"1.0","type":"link"}