{"product_id":"ic697bem741-ge-fanuc-series-90-70-fip-bus-controller","title":"IC697BEM741 GE Fanuc Series 90-70 FIP Bus Controller","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eIC697BEM741\u003c\/strong\u003e is a high-reliability FIP \/ WorldFIP (EN50170) Fieldbus Controller module designed for the GE Fanuc Series 90-70 programmable logic controller (PLC) platform. Operating as a single-slot Bus Expansion Module, this interface card establishes a deterministic network gateway capable of managing up to 128 connected field devices at a data communication speed of 1.0 Megabits per second (Mbps). Weighing approximately 4.0 pounds (1.81 kg), it provides heavy-duty central processing units with decentralized remote input\/output capability, maximizing network reach across large industrial automation plants.\u003c\/p\u003e\n\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDetailed Suffix Logic Breakdown:\u003c\/strong\u003e \n    \u003cul\u003e\n      \u003cli\u003e\n\u003cstrong\u003eIC697:\u003c\/strong\u003e Confirms native form-factor integration with the GE Fanuc Series 90-70 VME backplane ecosystem.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eBEM:\u003c\/strong\u003e Designates a dedicated Bus Expansion Module engineered for specialized network communication.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003e741:\u003c\/strong\u003e Specifies the operational hardware variant for the standard FIP\/WorldFIP Fieldbus architecture.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual-Channel Physical Layers:\u003c\/strong\u003e Features two discrete 9-pin FIP Bus connection ports (Channel 1 and Channel 2), providing robust physical line routing options for distributed device drops.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized Power Footprint:\u003c\/strong\u003e Draws a steady 1.3 Amps from the local backplane at a tight 5.0 VDC ($\\pm$0.1 VDC) supply tolerance, keeping maximum power consumption below 6.5 Watts.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Device Concentration:\u003c\/strong\u003e Addresses and scans up to 128 individual field devices, including Series 90-30 PLCs, remote I\/O scanner racks, and computer terminals over a network loop spanning up to 1000 meters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eSpecification Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eIC697BEM741\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eFIP \/ WorldFIP Fieldbus standard (EN50170 compliance)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eBus Baud Rate\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e1.0 Megabits per second (Mbps) continuous transmission\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eDevice Addressing Limit\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eUp to 128 remote fieldbus nodes or distributed I\/O targets\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eNetwork Scan Interval\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eDeterministic full sweep in 5 ms to 50 ms (node-count dependent)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003ePhysical Connections\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e2x 9-pin FIP ports (Ch1\/Ch2) | 1x 15-pin RS-232 serial interface\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eChassis Rack Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eInstalls in single slots of IC697CHS782 and IC697CHS783 VME racks\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eOperational Climate\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0°C to 60°C (32°F to 140°F); 5% to 95% non-condensing relative humidity\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eHardware MTBF Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eValidated in excess of 250,000 continuous operation hours\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation \u0026amp; Maintenance Guide\u003c\/h2\u003e\n\u003ch3\u003eChassis Mounting \u0026amp; Slot Seating\u003c\/h3\u003e\n\u003cp\u003eTurn off all input power to the automation rack before beginning. Slide the IC697BEM741 card directly into an open physical slot of an IC697CHS782 or IC697CHS783 VME style chassis. Seat the rear card-edge contacts fully into the backplane connectors and firmly hand-tighten the integrated faceplate screws to provide solid grounding.\u003c\/p\u003e\n\n\u003ch3\u003eFIP Bus Line \u0026amp; Segment Routing\u003c\/h3\u003e\n\u003cp\u003eConnect network trunk segments to the twin 9-pin FIP bus ports. Ensure high-quality shielded twisted-pair cabling is utilized to maintain the 1.0 Mbps transmission speed over longer spans. Keep total unrepeated copper cable lengths below 1000 meters, accounting for signal attenuation factors and proper end-of-line termination resistors.\u003c\/p\u003e\n\n\u003ch3\u003eHardware Reset \u0026amp; Maintenance\u003c\/h3\u003e\n\u003cp\u003eThe faceplate features a rugged manual mechanical pushbutton that triggers an immediate local hardware reset. This allows system engineers to clear minor communication lockups or re-initialize the onboard network chips instantly at the panel door without requiring software overrides or resetting the master PLC controller.\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDeterministic I\/O Scanning:\u003c\/strong\u003e Refreshes and synchronizes data maps from all 128 remote stations systematically during every continuous bus cycle, preventing critical real-time variable skew.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLocal Configuration Retention:\u003c\/strong\u003e Features non-volatile configuration memory storage that securely holds complex network mapping variables and address settings through total facility power outages.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAt-a-Glance Diagnostics:\u003c\/strong\u003e Integrates a 6-LED physical display, featuring MODULE OK and RUN indicators at the top, supplemented by 4 channel-specific LEDs for real-time serial traffic and error tracing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDedicated Firmware Uplink:\u003c\/strong\u003e Includes an independent 15-pin RS-232 serial interface port exclusively allocated for field-level firmware upgrades, insulating operational code from network data paths.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What software is required to configure the network maps on this module?\u003c\/strong\u003e\u003cbr\u003e\nA1: The communication parameters and remote device maps are fully configured and managed using standard Logicmaster 90-70 (Windows variant) or CIMPLICITY Control 90 engineering software packages.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Can this controller operate on standard RS-485 serial networks?\u003c\/strong\u003e\u003cbr\u003e\nA2: No. The IC697BEM741 is purpose-built to execute the specific FIP\/WorldFIP fieldbus protocols (EN50170). It cannot interface directly with traditional Modbus RTU or generic RS-485 industrial lines without an inline protocol converter.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What causes the network scan interval to shift between 5 ms and 50 ms?\u003c\/strong\u003e\u003cbr\u003e\nA3: The overall cycle time depends directly on the total number of live fieldbus nodes active on the network and the volume of cyclic data points requested. Fewer drops will drive the system toward the fast 5 ms benchmark, while a maxed-out 128-device bus triggers longer scan times.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050832068740,"sku":"IC697BEM741","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC697BEM741.jpg?v=1779201342","url":"https:\/\/www.etowonauto.com\/products\/ic697bem741-ge-fanuc-series-90-70-fip-bus-controller","provider":"Etowon Auto","version":"1.0","type":"link"}