{"product_id":"ic697bem733-ge-fanuc-series-90-70-genius-bus-receiver","title":"IC697BEM733 GE Fanuc Series 90-70 Genius Bus Receiver","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eIC697BEM733\u003c\/strong\u003e is a high-performance Remote I\/O Scanner Module developed by GE Fanuc (now Emerson Automation) for the robust Series 90-70 programmable logic controller system. Occupying a single mechanical slot in an IC697 remote chassis, this intelligent network board interfaces a remote rack directly to a master controller via a secure Genius I\/O bus. Weighing just 0.24 kg, it provides real-time, high-density data translation between field-level inputs\/outputs and the central CPU processor over extensive industrial plant networks.\u003c\/p\u003e\n\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Genius Network Topologies:\u003c\/strong\u003e Manages a single-ended or redundant daisy-chain bus setup over varied physical mediums, accommodating standard shielded twisted pair, high-performance Twinax, or noise-immune fiber optic lines.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExtended Field Cable Range:\u003c\/strong\u003e Supports long-distance infrastructure deployments, achieving a maximum operational loop length of up to 7500 feet at lower communication speeds to bridge widespread processing bays.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComprehensive Diagnostics Array:\u003c\/strong\u003e Employs an on-board triple LED indicator layout (\"Module OK\", \"I\/O Enabled\", and \"Bus Active\") to allow field mechanics to verify network health and slot status instantly without terminal access.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eSpecification Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eProduct Model Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eIC697BEM733\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eSystem Architecture\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eGE Fanuc Series 90-70 PLC System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eBus Network Communication\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eGenius I\/O Serial Bus Structure\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eConfigurable Baud Rates\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e38.4 Kbaud, 76.8 Kbaud, 153.6 Kbaud extended\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eMaximum Bus Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eUp to 32 nodes\/devices per bus segment\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003ePhysical Hardware Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e15-pin RS-422\/485 serial port \u0026amp; 9-pin monitor port\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eBackplane Current Draw\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0.8 Amps maximum from the +5V DC bus track\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0.24 kg (0.53 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eIndustrial Applications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDistributed Petrochemical Automation:\u003c\/strong\u003e Connects isolated sensor matrices and digital valve groupings on offshore oil skids or cross-facility tank farms back to main control vaults.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomotive Assembly Plants:\u003c\/strong\u003e Coordinates disparate I\/O racks located along expansive vehicle paint systems and automated welding cells without heavy multi-conductor routing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater Treatment Distribution:\u003c\/strong\u003e Links localized pump station sub-chassis across remote storage bays to central water-processing computers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePulp and Paper Mill Processing:\u003c\/strong\u003e Monitors high-density operational metrics in hot, corrosive environments by enabling distributed chassis closer to mechanical raw equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWiring \u0026amp; Installation\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChassis Slot Alignment:\u003c\/strong\u003e Slide the board firmly into its guide tracks inside the Series 90-70 remote rack. Ensure the top and bottom locking ears click securely into place before seating field connectors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBus Impedance Matching:\u003c\/strong\u003e Every Genius network run must be terminated at both physical ends using matching resistors. Select either 75, 100, 120, or 150 ohm parameters depending on the specific line cable type utilized.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommunication Interfacing:\u003c\/strong\u003e Wire serial network paths into the primary 15-pin D-shell interface. Utilize the secondary 9-pin configuration port specifically for hooking up a Hand-Held Monitor (HHM) tool during local commissioning.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Isolation Precautions:\u003c\/strong\u003e Disconnect all incoming power sources feeding the remote rack backplane prior to insertion or extraction of the module assembly to shield logic paths against static spikes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized Power Management:\u003c\/strong\u003e Drawing a minimal 0.8 Amps from the local backplane track avoids power supply saturation, leaving greater capacity for active input\/output blocks inside the remote rack.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVariable Drop Scale:\u003c\/strong\u003e Supports a flexible maximum count of remote drops that scales automatically with the configured baud rate, striking a perfect balance between speed and physical node density.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDeterministic I\/O Processing:\u003c\/strong\u003e The underlying Genius transmission architecture ensures predictable loop times, delivering high-speed execution profiles critical for complex sequential automation logic.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the purpose of the 9-pin connector situated on the front plate?\u003c\/strong\u003e\u003cbr\u003e\nA1: The 9-pin port is dedicated to connecting a hand-held Genius configuration monitor or programming unit, allowing engineering crews to diagnose, configure, and isolate errors locally right at the remote sub-rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can I hot-swap the IC697BEM733 module while the remote rack is fully powered up?\u003c\/strong\u003e\u003cbr\u003e\nA2: No. The legacy GE Fanuc Series 90-70 systems require complete electrical isolation when inserting or pulling hardware assemblies. Removing this module while hot can induce system faults or compromise backplane integrity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How does changing the communication speed from 153.6 Kbaud to 38.4 Kbaud affect my network?\u003c\/strong\u003e\u003cbr\u003e\nA3: Dropping the network speed to 38.4 Kbaud reduces data throughput rates but stretches the physical cable budget dramatically, letting your Genius bus track extend up to 7500 feet reliably.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050831970436,"sku":"IC697BEM733","price":115.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC697BEM733.jpg?v=1779373883","url":"https:\/\/www.etowonauto.com\/products\/ic697bem733-ge-fanuc-series-90-70-genius-bus-receiver","provider":"Etowon Auto","version":"1.0","type":"link"}