{"product_id":"ic697alg440-ge-fanuc-series-90-30-analog-input-card","title":"IC697ALG440 GE Fanuc Series 90-30 Analog Input Card","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eGE Fanuc IC697ALG440\u003c\/strong\u003e is a high-density, 16-channel Analog Input Expander Module engineered to scale up the monitoring capacity of your GE Series 90 industrial control system. Weighing just 0.61 kilograms (1.34 lbs) with a compact 4 cm x 21.8 cm x 29.2 cm profile, this module serves as an expansion interface that captures a high volume of field data. By pairing seamlessly with base converter modules, it enables complex control systems to monitor extensive arrays of 4-20 mA and voltage transmitters simultaneously.\u003c\/p\u003e\n\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e16-Channel High-Density Expansion:\u003c\/strong\u003e Maximizes rack real estate by packing 16 distinct current inputs onto a single slot footprint, lowering overall hardware installation costs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual-Signal Compatibility Range:\u003c\/strong\u003e Built to process both standard 4 to 20 mA industrial current loops and versatile -10 to +10 VDC voltage spans for wide-ranging process telemetry.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFactory-Calibrated Precision:\u003c\/strong\u003e Shipped with a highly stable factory calibration set at 10 Volts ±2mV, providing exceptional plug-and-play measurement accuracy directly out of the box.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eSpecification Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eBrand \/ Model Part No.\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eGE Fanuc \/ IC697ALG440\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eGross Weight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0.61 kilograms (1.34 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eModule Classification\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eAnalog Input Expander Module (Series 90 Platform)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eTotal Signal Inputs\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e16 Current \/ Voltage Input Channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eCurrent Signal Window\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e4 to 20 mA loop current range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eVoltage Signal Window\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e-10 VDC to +10 VDC range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eCalibration Reference Limit\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eFactory set at 10 Volts ±2 mV\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eInternal Power Consumption\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e+5 VDC backplane logic power supply requirement\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003ePhysical Form Dimensions\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e4.0 cm (W) x 21.8 cm (D) x 29.2 cm (H)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation \u0026amp; Engineering Guide\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHardware Pairing Setup:\u003c\/strong\u003e Slide the lightweight 0.61 kg expander card into its designated slot immediately adjacent to the base analog converter module. Ensure backplane connectors mate cleanly to maintain reliable bus expansion.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eField Instrument Shielding:\u003c\/strong\u003e Wire your 4-20mA or ±10V instrumentation directly to the module terminal blocks. Run all signal cabling through separate grounded industrial conduits to shield the high-density analog matrix from high-power electromagnetic emissions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Maintain proper air gaps around the 4 cm wide housing. Its energy-efficient design requires low power, but clean convection routing inside the enclosure helps prevent heat pooling from surrounding equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Does the IC697ALG440 act as a standalone analog processing module?\u003c\/strong\u003e\u003cbr\u003e\nA1: No. This hardware is classified as an expander module; it must be coupled with a primary base analog converter module to pass digitized instrumentation loop signals to the processor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What benefit does the factory-set 10V ±2mV calibration offer during installation?\u003c\/strong\u003e\u003cbr\u003e\nA2: It guarantees highly stable operational baselines without demanding field calibration adjustments during hardware commission, saving considerable engineering hours on startup.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can this compact module be mounted into tight enclosure assemblies safely?\u003c\/strong\u003e\u003cbr\u003e\nA3: Yes. With physical dimensions of 4 cm x 21.8 cm x 29.2 cm, its compact footprint fits cleanly into standard depth industrial cabinets while providing robust 16-channel tracking.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050794582148,"sku":"IC697ALG440","price":116.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC697ALG440-GE.jpg?v=1781620047","url":"https:\/\/www.etowonauto.com\/products\/ic697alg440-ge-fanuc-series-90-30-analog-input-card","provider":"Etowon Auto","version":"1.0","type":"link"}