{"product_id":"ic693bem320-ge-fanuc-series-90-30-i-o-communication-module","title":"IC693BEM320 GE Fanuc Series 90-30 I\/O Communication Module","description":"\u003ch2 style=\"color: #1976d2; font-weight: bold; font-size: 1.6em; margin-bottom: 15px;\"\u003e\n  \u003cspan style=\"color: #1976d2; font-weight: bold;\"\u003eGE Fanuc IC693BEM320\u003c\/span\u003e 2-Port Serial Interface Module\n\u003c\/h2\u003e\n\n\u003cp style=\"font-size: 1em; line-height: 1.5; color: #333; margin-bottom: 20px;\"\u003e\n  The module functions as a high-performance 2-port serial communication interface engineered for GE Fanuc Series 90-30 and 90-70 PLC systems. Occupying a single backplane slot, it delivers fast, deterministic I\/O scanning and flexible networking options across industrial RS-485 and RS-422 infrastructure.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1976d2; font-weight: bold; font-size: 1.3em; margin-top: 20px; margin-bottom: 10px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px; font-size: 0.95em;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333; width: 40%;\"\u003eManufacturer\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eGE Fanuc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eModel Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eIC693BEM320\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eInterface Architecture\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e2-Port Design (RS-485 \u0026amp; RS-422)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eI\/O Capacity\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e32 or 64 points (jumper-selectable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eData Throughput\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eUp to 120 KB\/s\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eBaud Rate Range\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e9,600 to 115,200 bps (selectable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eMax Cable Distance\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e1,200 meters per port\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eBackplane Power Draw\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e5 VDC @ 150 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eNetwork Capacity\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eUp to 16 slave modules per master link\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eHardware Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e200 g (Net Weight)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eDimensions\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e45 mm × 100 mm × 75 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eReliability Metrics\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eMTBF: 75,000 hours | Scan Cycle: \u0026lt; 2 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #1976d2; font-weight: bold; font-size: 1.3em; margin-top: 20px; margin-bottom: 10px;\"\u003eQuick Installation Guide\u003c\/h3\u003e\n\u003cul style=\"padding-left: 20px; line-height: 1.5; color: #333; margin-bottom: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 6px;\"\u003eSet the onboard configuration jumper to establish either a 32-point or 64-point point-density layout before insertion.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 6px;\"\u003eSlide the 200 g lightweight communication module firmly into any single available slot of your Series 90-30 or 90-70 backplane.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 6px;\"\u003eConfirm the \"OK\" and \"RDY\" status LEDs illuminate steady amber\/green following initial CPU system power-up diagnostic cycles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1976d2; font-weight: bold; font-size: 1.3em; margin-top: 20px; margin-bottom: 10px;\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 10px; color: #333; line-height: 1.5;\"\u003e\n  \u003cstrong\u003eQ1: What is the benefit of the integrated dual-protocol design?\u003c\/strong\u003e\u003cbr\u003e\n  A1: The physical division into dedicated RS-485 and RS-422 transceiver links allows users to execute long-distance fieldbus wiring tasks up to 1,200 meters without external converter hardware.\n\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px; color: #333; line-height: 1.5;\"\u003e\n  \u003cstrong\u003eQ2: How fast does the IC693BEM320 process master-to-slave updates?\u003c\/strong\u003e\u003cbr\u003e\n  A2: Operating with a premium data throughput capability up to 120 KB\/s, the card maintains deterministic scanning speeds that drop overall bus cycle steps under a strict 2 ms window.\n\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px; color: #333; line-height: 1.5;\"\u003e\n  \u003cstrong\u003eQ3: Does this communication controller require dedicated external power feeds?\u003c\/strong\u003e\u003cbr\u003e\n  A3: No. The internal logic operates entirely on a low 150 mA draw sourced directly from the standard 5 VDC system backplane rail.\n\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050821255300,"sku":"IC693BEM320","price":186.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC693BEM320.jpg?v=1781103239","url":"https:\/\/www.etowonauto.com\/products\/ic693bem320-ge-fanuc-series-90-30-i-o-communication-module","provider":"Etowon Auto","version":"1.0","type":"link"}