{"product_id":"ic670mdl644-logic-input-module-ge-fanuc-16-point-24vdc","title":"IC670MDL644 Logic Input Module GE Fanuc 16 Point 24VDC","description":"\u003ch2 style=\"color: #2c6e9e;\"\u003eGE Fanuc IC670MDL644 24VDC Fast Input Module\u003c\/h2\u003e\n\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong style=\"color:#2c6e9e;\"\u003eIC670MDL644\u003c\/strong\u003e is a 16 point positive negative fast input module from GE Fanuc Field Control series. Rated for 24 Volts DC with input range 0 to 30 Volts DC. Features fast response, individual LED indicators per point, and user input to logic isolation at 250 Volts AC. Module weight 2 lbs (0.91 kg).\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px;\"\u003e\n\u003ctbody\u003e\n\u003cth style=\"padding:10px; border:1px solid #ccc; text-align:left; width:40%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding:10px; border:1px solid #ccc; text-align:left;\"\u003eValue\u003c\/th\u003e\n\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eField Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eIC670MDL644\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eRated Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e24 Volts DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e0 to 30 Volts DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eUser Input Current\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e8 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eInput Impedance\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e3kΩ typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eLED Indicators\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e1 per point + PWR LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eUser Input to Logic Isolation\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e250 Volts AC continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eUser Input to Frame Ground Isolation\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e1500 Volts AC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003ePoint to Point Isolation\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eCurrent Drawn from Power Supply\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e80 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e2 lbs (0.91 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eLogic Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px;\"\u003e\n\u003ctbody\u003e\n\u003cth style=\"padding:10px; border:1px solid #ccc; text-align:left; width:40%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding:10px; border:1px solid #ccc; text-align:left;\"\u003eValue\u003c\/th\u003e\n\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003ePositive Logic On-state\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e+15 to +30 Volts DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003ePositive Logic Off-state\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e0 to +5 Volts DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eNegative Logic On-state\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e-15 to -30 Volts DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eNegative Logic Off-state\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e0 to -5 Volts DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 discrete fast inputs in single group\u003c\/li\u003e\n\u003cli\u003ePositive or negative logic selectable\u003c\/li\u003e\n\u003cli\u003eFast response time for high speed applications\u003c\/li\u003e\n\u003cli\u003e1 LED indicator per input point plus power LED\u003c\/li\u003e\n\u003cli\u003eParallel to serial converters for data processing\u003c\/li\u003e\n\u003cli\u003eInternal resistor capacitor network for input thresholds and filtering\u003c\/li\u003e\n\u003cli\u003eSupports box terminal or barrier terminal blocks for field wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBus interface unit provides 5V logic power\u003c\/li\u003e\n\u003cli\u003eExternal 24 Volts DC power supply required for input devices\u003c\/li\u003e\n\u003cli\u003ePositive inputs receive current from input devices\u003c\/li\u003e\n\u003cli\u003eNegative inputs provide current to input devices\u003c\/li\u003e\n\u003cli\u003ePower LED shows power status after proper connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the input voltage range for IC670MDL644?\u003c\/strong\u003e\u003cbr\u003eA1: Input voltage range is 0 to 30 Volts DC with rated voltage 24 Volts DC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does this module require external power?\u003c\/strong\u003e\u003cbr\u003eA2: Yes. External 24 Volts DC power supply required for input devices. Bus interface unit provides 5V logic power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What is the isolation rating?\u003c\/strong\u003e\u003cbr\u003eA3: 250 Volts AC continuous user input to logic isolation, 1500 Volts AC user input to frame ground for 1 minute.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52140948553860,"sku":"IC670MDL644","price":126.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC670MDL644.jpg?v=1781099655","url":"https:\/\/www.etowonauto.com\/products\/ic670mdl644-logic-input-module-ge-fanuc-16-point-24vdc","provider":"Etowon Auto","version":"1.0","type":"link"}