{"product_id":"honeywell-fc-tdol-07120-digital-output-module","title":"Honeywell FC-TDOL-07120 Digital Output Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eFC-TDOL-07120\u003c\/strong\u003e (general type FS-TDOL-07120) is a 7-channel line-monitored Field Termination Assembly (FTA) module designed for the Honeywell Safety Manager system. This module serves as a heavy-duty power interface for critical field loads requiring 120Vac or 120Vdc digital outputs. Equipped with 7 fused relay contact outputs, it bridges low-voltage control logic with high-capacity field equipment, providing integrated loop diagnostics and high galvanic isolation for emergency shutdown and critical control loops.\u003c\/p\u003e\n\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdvanced Line Monitoring:\u003c\/strong\u003e Integrates dedicated surveillance circuits across all 7 output channels to detect open and short circuits in field wiring.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Capacity Switching:\u003c\/strong\u003e Features robust onboard relays supporting industrial field loads up to 240VA (AC) or 150W (DC) per channel.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCross-Module Interconnection:\u003c\/strong\u003e Connects seamlessly with SDO-0824 output and SDI-1624 input modules via standard system cables to drive logic and process faults.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVisual Diagnostics:\u003c\/strong\u003e Includes dedicated status LEDs for each relay channel, allowing instantaneous visual verification of output states during maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eSpecification Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eFC-TDOL-07120 \/ FS-TDOL-07120\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e7 Digital Output Channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eOutput Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e120V AC or 120V DC (+\/- 20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eMax Output Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e2A per channel (at 120V AC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eMaximum Channel Load\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e240VA (Resistive\/Inductive) or 150W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eChannel Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e2A individual channel fuses\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eExpected Relay Life\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e100,000 electrical operations \/ 30,000,000 mechanical operations\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eMounting Options\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eDIN EN rails: TS32 \/ TS35 x 7.5\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eDimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e240 x 109 x 71 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eCE, UL, CSA, TUV\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation \u0026amp; Maintenance Guide\u003c\/h2\u003e\n\u003ch3\u003eModule Wiring and Interconnection\u003c\/h3\u003e\n\u003cp\u003eInterface the module to the upstream control layers using dedicated system interconnection cables. Connect channels 1 through 7 of the SDO-0824 module to control the respective output relays, and wire the integrated line-monitoring outputs back to channels 1 through 15 of the SDI-1624 input module.\u003c\/p\u003e\n\n\u003ch3\u003eDIN Rail Mounting\u003c\/h3\u003e\n\u003cp\u003eSnap the rugged housing securely onto standard DIN EN rails (compatible with TS32 or TS35 × 7.5 profiles). Ensure sufficient clearance around the assembly inside the enclosure to facilitate heat dissipation from inductive loads and allow clear visibility of the relay state LEDs.\u003c\/p\u003e\n\n\u003ch3\u003eFuse and Service Safeties\u003c\/h3\u003e\n\u003cp\u003eEach output channel is individually isolated by a 2A fuse. If a field short-circuit occurs, isolate the main 120V power source before extracted or replacing the blown fuse. Always execute test operations via the application logic to verify loop feedback integrity post-replacement.\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUniversal Load Capability:\u003c\/strong\u003e Formulated to switch both inductive and resistive industrial field loads safely without requiring external snubber circuits.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Operational Lifespan:\u003c\/strong\u003e Heavy-duty relay construction delivers up to 30 million mechanical cycles, lowering total cost of ownership and minimizing downtime.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFull Safety Compliance:\u003c\/strong\u003e Backed by CE, UL, CSA, and TUV certifications, ensuring seamless deployment within strict regulatory and SIL-rated environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How does the line-monitoring feature operate on this module?\u003c\/strong\u003e\u003cbr\u003e\nA1: Line-monitoring circuits on each channel track field loop continuity. This diagnostic routing is activated by channel 8 of the SDO-0824 module and processed via channels 1 to 15 of the SDI-1624 input module using specialized application logic.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Can I mix 120V AC and 120V DC loads on the same module?\u003c\/strong\u003e\u003cbr\u003e\nA2: While the contacts are rated for both 120V AC and 120V DC (+\/- 20%), it is standard engineering practice to maintain consistent voltage types across a single physical board to prevent cross-contamination of power rails.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What is the maximum switched power rating for the contacts?\u003c\/strong\u003e\u003cbr\u003e\nA3: The relay contacts support a maximum switched power threshold of 1250VA for alternating current loops and 60 Watts for direct current safety loops.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51864168628356,"sku":"FC-TDOL-07120","price":334.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/FC-TDOL-07120.jpg?v=1779002955","url":"https:\/\/www.etowonauto.com\/products\/honeywell-fc-tdol-07120-digital-output-module","provider":"Etowon Auto","version":"1.0","type":"link"}