{"product_id":"ge-fanuc-series-90-30-plc-tbqc-interface-cable-ic693cbl331","title":"GE Fanuc Series 90-30 PLC TBQC Interface Cable IC693CBL331","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe GE Fanuc \/ Emerson \u003cstrong\u003eIC693CBL331\u003c\/strong\u003e is a high-reliability, 2-meter connection cable designed to interface with the high-density I\/O modules of the Series 90-30 Programmable Logic Controller (PLC) system. Primarily utilized with 16-point and 32-point I\/O modules, this specialized assembly serves as the critical pathway linking PLC input\/output channels to a Terminal Block Quick Connect (TBQC) faceplate adapter or terminal board. \u003c\/p\u003e\n\n\u003cp\u003eAt a physical weight of only \u003cstrong\u003e0.22 kg\u003c\/strong\u003e, this highly flexible, lightweight cable features a low-profile 90-degree 24-pin connector on both ends. This right-angle design reduces front-panel protrusion in the enclosure, making it ideal for shallow control cabinets and dense system layouts. Built with an industrial-grade thermoplastic elastomer (TPE) jacket and 24 individual tinned-copper conductors, the IC693CBL331 provides superior mechanical flexibility, chemical resistance, and electrical integrity in harsh manufacturing environments.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cp\u003eThe model number structure defines the precise physical build and industrial intent of this cable assembly:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIC693CBL:\u003c\/strong\u003e Identifies the standard cable and connection accessories product line for GE Fanuc\/Emerson Series 90-30 PLCs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e331 Suffix:\u003c\/strong\u003e Specifies the mechanical variant characterized by a 2-meter length, a 90-degree left-side 24-pin physical connector layout, and compatibility with the TBQC interface ecosystem.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 15px; margin-bottom: 20px;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f7fc;\"\u003e\n      \u003cth style=\"border: 1px solid #a9bccc; text-align: left; padding: 10px; width: 40%;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #a9bccc; text-align: left; padding: 10px;\"\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eCable Length\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003e2 meters (approx. 6.6 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9fbfd;\"\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eOuter Diameter (OD)\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003e8.5 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eConductor Details\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003e24 AWG tinned copper; 24 independent conductors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9fbfd;\"\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eVoltage Rating\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003e300 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eCurrent Carrying Capacity\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003e1.2 A maximum per conductor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9fbfd;\"\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003e-30°C to 70°C (-22°F to 158°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003ePermissible Humidity\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003e10% to 90% RH, non-condensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9fbfd;\"\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eMinimum Bend Radius\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003e55 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eBare Cable Weight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003e0.22 kg (0.48 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9fbfd;\"\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eConnector Profile\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003e2.0-inch depth clearance (90-degree, 24-pin terminal interface)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eSheath Material\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003eIndustrial-grade Thermoplastic Elastomer (TPE)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9fbfd;\"\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eFlex Endurance\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003e120,000+ flex cycles\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eTensile Strength\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003e180 N\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9fbfd;\"\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eEMI Immunity\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003e25 V\/m\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eUV Weathering Resistance\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003eUp to 500 hours direct UV exposure\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003ch3\u003eEnclosure Space \u0026amp; Connector Depth Considerations\u003c\/h3\u003e\n\u003cp\u003eThe 90-degree terminal connector of the IC693CBL331 requires a physical clearance depth of 2.0 inches (approximately 50.8 mm) once mated to the PLC front faceplate. Ensure your electrical panel depth accounts for this additional 2-inch adapter profile to avoid mechanical stress on the mating pins when closing the cabinet doors. Since the unit is incredibly lightweight at 0.22 kg, it exerts negligible gravitational pull on the I\/O module pins; however, proper tie-downs are recommended to avoid accidental disconnections.\u003c\/p\u003e\n\n\u003ch3\u003eMechanical Strain Relief \u0026amp; Routing\u003c\/h3\u003e\n\u003cp\u003eMaintain a dynamic routing profile that respects the cable's 55 mm minimum bend radius. For static or moderately dynamic flexing tracks, ensure the cable is not routed over sharp metallic chassis corners. The durable TPE jacket has a tensile strength of 180 N, allowing standard pulling forces during initial installation, but structural zip-ties should not be over-tightened to prevent crushing the internal 24 AWG conductors.\u003c\/p\u003e\n\n\u003ch3\u003eElectrical Integration and Current Derating\u003c\/h3\u003e\n\u003cp\u003eThis cable is strictly rated for up to 1.2 A per conductor. For high-density 16-point modules operating at maximum load limits, pay attention to thermal limits. If your field-side devices demand higher current profiles (\u0026gt;1.2 A continuously), the TBQC configuration using the IC693CBL331 is not recommended. In those high-current scenarios, point-to-point discrete wiring directly to standard heavy-duty terminal blocks is required to prevent heat buildup.\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003ch3\u003eOptimized Cabinet Footprint\u003c\/h3\u003e\n\u003cp\u003eBy employing a 90-degree right-angle connector, the IC693CBL331 effectively redirects routing paths vertically along the faceplate of the Series 90-30 PLC rack. This significantly reduces the dead-volume clearance required in front of the PLC, facilitating the use of shallower, more cost-effective industrial control cabinets.\u003c\/p\u003e\n\n\u003ch3\u003eTough Industrial-Grade TPE Jacket\u003c\/h3\u003e\n\u003cp\u003eUnlike standard PVC cables that easily dry out, crack, or degrade under oil-mist exposure, the advanced TPE sheathing withstands up to 120,000 continuous flex cycles and features robust UV resistance for up to 500 exposure hours. This resilience guarantees consistent signal transmission in areas with high machinery vibration or outdoor control environments.\u003c\/p\u003e\n\n\u003ch3\u003eSuperior Noise and Physical Defense\u003c\/h3\u003e\n\u003cp\u003eEquipped with an EMI immunity of 25 V\/m and 24 AWG tinned-copper conductors, the cable preserves signal integrity against surrounding electromagnetic interference caused by nearby Variable Frequency Drives (VFDs) and high-power contactors.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the differences between the IC693CBL331 and left\/right cable pairings on 32-point modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: For high-density 32-point modules, two connectors are aligned side-by-side. The IC693CBL331 is engineered with specific keying and a 90-degree exit path configured to route clean on the right side of the I\/O adapter module when looking directly at the front of the PLC rack, ensuring no mechanical interference with the neighboring left-side cable.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Can I use this cable with non-GE PLC systems or custom pinouts?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: While the cable uses 24 AWG tinned-copper wires with general 300 V \/ 1.2 A ratings, its dual-end 24-pin 90-degree connectors are specifically keyed to fit Series 90-30 and PACSystems RX3i TBQC platforms. Custom pin-out usage is highly discouraged unless the target interfaces are explicitly documented as pin-compatible.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: How does temperature affect the shelf life and operation of the TPE jacket?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: The cable is rated for cold-weather operations down to -30°C and heat levels up to 70°C. Storage shelf life is typically listed at 1 year under ambient conditions to guarantee the physical integrity of the rubber-like TPE compounds before physical deployment. Once installed, its operational lifespan is significantly extended.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050814308484,"sku":"IC693CBL331","price":148.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC693CBL331.jpg?v=1784122697","url":"https:\/\/www.etowonauto.com\/products\/ge-fanuc-series-90-30-plc-tbqc-interface-cable-ic693cbl331","provider":"Etowon Auto","version":"1.0","type":"link"}