{"product_id":"ge-fanuc-ic697cbl700-series-90-70-power-supply-cable","title":"GE Fanuc IC697CBL700 Series 90-70 Power Supply Cable","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eIC697CBL700\u003c\/strong\u003e is a heavy-duty 1.5-meter (59 inches) power supply extension cable engineered for the GE Fanuc Series 90-70 programmable logic controller (PLC) architecture. Weighing 0.3 kg with a flexible 6.5mm diameter profile, this interconnect assembly bridges primary and secondary expansion racks. It delivers stable 5V DC power and critical handshaking control signals directly between rack backplanes, enabling cohesive multi-rack input\/output configuration and balanced power distribution across complex industrial automation setups.\u003c\/p\u003e\n\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDetailed Suffix Logic Breakdown:\u003c\/strong\u003e \n    \u003cul\u003e\n      \u003cli\u003e\n\u003cstrong\u003eIC697:\u003c\/strong\u003e Identifies native compatibility with the flagship GE Fanuc Series 90-70 modular hardware ecosystem.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eCBL:\u003c\/strong\u003e Designates high-reliability industrial interface cable assemblies.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003e700:\u003c\/strong\u003e Specifies the function suffix for 5V power extension and multi-rack logic synchronization.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBalanced Power Architecture:\u003c\/strong\u003e Engineered to handle a 5A maximum current capacity safely, enabling clean distribution with up to 100W on the primary rack and 55W maximum on the secondary expansion rack.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePremium Signal Contacts:\u003c\/strong\u003e Equipped with a robust 9-pin D-type connector featuring gold-plated pin contacts to eliminate oxidation, contact resistance, and intermittent communication faults in vibrating environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Lead Integrity:\u003c\/strong\u003e Internal wiring uses 22AWG tinned copper conductors jacketed in specialized UL 62-rated PVC insulation for superior resistance against chemical degradation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eSpecification Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eIC697CBL700\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eManufacturer \/ Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eGE Fanuc \/ Series 90-70 PLC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003ePhysical Length \u0026amp; Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e1.5 meters (59 inches) \/ 6.5 mm cable outer diameter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eComponent Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eNet weight: 0.3 kg (300 grams)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eElectrical Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e5V DC operating voltage \/ 5A maximum continuous current\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eConnector Pinout Configuration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e9-pin D-type sub-connector with gold-plated contact pins\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eIntegrated Safety Clamps\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eOvervoltage clamp at 5.5V DC \/ Overcurrent via 10A fast-blow fuse\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eThermal Operating Band\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0°C to +50°C (Derate 0.5W\/°C when working above 35°C)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eSignal Integrity Benchmark\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e99% signal transmission retention verified at 1 MHz test frequencies\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation \u0026amp; Maintenance Guide\u003c\/h2\u003e\n\u003ch3\u003eMechanical Securement \u0026amp; Torque\u003c\/h3\u003e\n\u003cp\u003eTo establish an oil-tight, vibration-proof connection, lock the 9-pin D-type connectors using 4 integrated M2.5 mounting screws. Utilize a precision torque screwdriver to tighten the hardware to a torque range between 0.8 N·m and 1.2 N·m. Avoid over-tightening to protect the D-sub housing from cracking.\u003c\/p\u003e\n\n\u003ch3\u003eBend Radius and Pull Constraints\u003c\/h3\u003e\n\u003cp\u003eMaintain a strict minimum static bend radius of 50 mm along the length of the 6.5mm PVC jacket. Sharp structural bends can sever or fatigue the inner 22AWG copper cores. During routing through cabinet conduit trunks, ensure the mechanical pulling force does not exceed 10N to protect internal crimp joints.\u003c\/p\u003e\n\n\u003ch3\u003ePhysical Shield Interfacing\u003c\/h3\u003e\n\u003cp\u003eThe cable incorporates a clear polycarbonate cover plate over connection junctions to block external contaminants and physical impacts. When running wires near high-voltage motor control equipment, ground the internal shielding to minimize electromagnetic crosstalk and retain a 99% signal integrity baseline.\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHardware Fault Mitigation:\u003c\/strong\u003e Transmits the proactive ACFAIL status control line, which activates within 15ms of a supply drop to allow orderly PLC memory backup routines before power loss.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSynchronized Cold Booting:\u003c\/strong\u003e Incorporates the SYSRESET hardware command line, holding the expansion bus in a safe reset state for 200ms ($\\pm$5ms tolerance) post-startup to allow stabilization.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExtended Module Compatibility:\u003c\/strong\u003e Allows secondary chassis slots to seamlessly power legacy 12V IC697 automation modules, maximizing your existing capital hardware investments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBroad Storage Resilience:\u003c\/strong\u003e Built to endure long-term industrial warehouse storage within a wide thermal spectrum of -20°C to +70°C and 5% to 90% non-condensing relative humidity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What happens if the local panel ambient temperature exceeds 35°C?\u003c\/strong\u003e\u003cbr\u003e\nA1: The cable’s thermal profile mandates power derating of 0.5W\/°C for ambient temperatures higher than 35°C up to the 50°C maximum threshold. Ensure proper panel cooling or ventilation if operating the rack near these high limits.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Can I splice two IC697CBL700 cables together to extend the distance to 3.0 meters?\u003c\/strong\u003e\u003cbr\u003e\nA2: Splicing is strongly discouraged. The 5V DC rail is highly sensitive to line resistance losses. Extending the cable beyond its factory-calibrated 1.5m length drops the voltage, which can trigger the 5.5V safety clamp or cause expansion rack power dropouts.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: How does the cable protect the Series 90-70 backplane from short circuits?\u003c\/strong\u003e\u003cbr\u003e\nA3: The assembly incorporates an inline 10A fast-blow fuse coupled with an active overvoltage crowbar circuit that clamps inputs at 5.5V, absorbing destructive voltage spikes before they can damage secondary I\/O modules.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050832134276,"sku":"IC697CBL700","price":112.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC697CBL700.jpg?v=1779202159","url":"https:\/\/www.etowonauto.com\/products\/ge-fanuc-ic697cbl700-series-90-70-power-supply-cable","provider":"Etowon Auto","version":"1.0","type":"link"}