{"product_id":"ge-fanuc-ic695ftb001-pacmotion-rx3i-fiber-i-o-terminal-block","title":"GE Fanuc IC695FTB001 PACMotion RX3i Fiber I\/O Terminal Block","description":"\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold; width: 40%;\"\u003eModel \/ Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003e\u003cspan style=\"color: #0044cc; font-weight: bold;\"\u003eIC695FTB001\u003c\/span\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eBrand \/ System\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003eGE Fanuc \/ PACMotion RX3i (Series 90-30 style)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003eActive Fiber I\/O Terminal Block \/ Motion Interface\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eInput Voltage Range\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003e19.2 to 28.8 V DC (0.45 A @ 24 V)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eAuxiliary Power Output\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003e5 V DC (0.5 A maximum)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eDigital Inputs\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003e16 x 24 V Gen-Purpose, 8 x 5 V Inputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eDigital Outputs\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003e8 x 24 V Outputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eDifferential I\/O\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003e4 x 5 V Differential Inputs\/Outputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eAnalog I\/O Channels\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003e2 x Analog In (±10 V Diff), 2 x Analog Out (±10 V Single-Ended)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eModule Interface Port\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003eFiber Optic Cable (Supports up to 100 meters)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eIntegrated Protection\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003eElectronic Overload Protection \u0026amp; Quad Encoder Open-Circuit Detection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003e141.2 × 125.5 × 62.5 mm (5.56 × 4.94 × 2.46 inches)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eNet Product Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003e0.79 kg (Approx. 1.74 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold;\"\u003eMounting Setup\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px;\"\u003e35 mm DIN Rail (Vertical placement required)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe GE Fanuc \u003cspan style=\"color: #0044cc; font-weight: bold;\"\u003eIC695FTB001\u003c\/span\u003e is an active fiber optic I\/O terminal block designed exclusively to expand the distributed motion control capabilities of PACMotion RX3i systems. Weighing approximately 0.79 kg, this compact module operates on a wide 19.2 to 28.8 V DC input range, bridging specialized field instrumentation directly with central processors to deliver seamless data synchronization over high-noise industrial environments.\u003c\/p\u003e\n\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Density Motion Interface:\u003c\/strong\u003e Combines discrete, analog, and 5 V differential channels to support complex hardware accessories including touch probes, home switches, and over-travel limit points.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eImmune Fiber Optic Media:\u003c\/strong\u003e Uses a dedicated fiber optic bus to establish rock-solid controller handshakes across long production spaces reaching lengths up to 100 meters.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSmart System Protection:\u003c\/strong\u003e Integrates automatic electronic overload protection alongside hardware-level quad encoder open-circuit diagnostics to safeguard connected sensors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStreamlined Field Maintenance:\u003c\/strong\u003e This 0.79 kg unit features removable terminal block headers, letting engineers hot-swap physical wiring assemblies swiftly during module replacements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003cp\u003eSnap the 0.79 kg module securely onto a standard 35 mm DIN rail. To protect internal logic circuits from overheating, always mount the 141.2 × 125.5 × 62.5 mm chassis in a vertical position to facilitate natural convection. Terminate the nominal 24 V DC supply source into the power inputs, and keep your fiber optic link route under the maximum 100-meter operating threshold.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What motion-specific sensor functions can be linked directly to this block?\u003c\/strong\u003e\u003cbr\u003e\nA1: The physical input arrays are engineered to directly process diagnostic markers, high-speed touch probes, home position switches, and over-travel safety limits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the maximum distance supported for fiber optic cable runs?\u003c\/strong\u003e\u003cbr\u003e\nA2: The module maintains full communication integrity and sub-millisecond data refresh rates across fiber links up to a maximum length of 100 meters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Why must the IC695FTB001 be mounted strictly in a vertical orientation?\u003c\/strong\u003e\u003cbr\u003e\nA3: Vertical mounting is an environmental constraint required to enable optimal thermal dissipation, ensuring the 0.79 kg component stays safe from overheating during heavy steady-state power operations.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050831315076,"sku":"IC695FTB001","price":146.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC695FTB001-2.jpg?v=1781620820","url":"https:\/\/www.etowonauto.com\/products\/ge-fanuc-ic695ftb001-pacmotion-rx3i-fiber-i-o-terminal-block","provider":"Etowon Auto","version":"1.0","type":"link"}