{"product_id":"ge-fanuc-ic693mdl330-output-module-8-point-120-240v-ac","title":"GE Fanuc IC693MDL330 Output Module | 8 Point 120\/240V AC","description":"\u003ch2 style=\"color:#0055A4;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color:#0055A4;\"\u003eGE Fanuc IC693MDL330 Discrete Output Module\u003c\/strong\u003e is an 8-point AC output module for the Series 90-30 family. It operates at 120\/240V AC with an 85-264V AC range at 50\/60 Hz. This module delivers 2A maximum per point for controlling solenoids, contactors, and valves.\u003c\/p\u003e\n\n\u003ch3\u003eModule Specifications\u003c\/h3\u003e\n\u003ctable width=\"100%\" border=\"0\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd width=\"40%\"\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd width=\"60%\"\u003e120\/240V AC (85-264V AC, 50\/60 Hz)\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eOutputs per Module\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e8 outputs (arranged in two groups of 4)\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e1500V minimum between field side and logic side\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eOutput Current (Max per point)\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e2A\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eOutput Current (Max per group at 40°C)\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e4A\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eOutput Voltage Drop\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e1.5V maximum\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e20A maximum for 1 cycle\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eMinimum Load Current\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e100mA\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eOutput Leakage Current (at 120V AC)\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e3mA maximum\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eOutput Leakage Current (at 240V AC)\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e6mA maximum\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eOn Response Time\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e1ms maximum\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eOff Response Time\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e0.5 cycles maximum\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e160mA from the 5V backplane bus (all outputs active)\u003c\/td\u003e\n   \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e0.45 kg (0.99 lbs)\u003c\/td\u003e\n   \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003cp\u003eMount the module in any Series 90-30 rack slot. Connect AC loads between the output terminal and neutral. Each output handles 2A continuous and 20A inrush for one cycle. The 8 outputs are arranged in two groups of 4 with 1500V isolation. Ensure minimum load current of 100mA for reliable switching.\u003c\/p\u003e\n\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe IC693MDL330 delivers 1ms on response time for rapid actuator control. Off response time of 0.5 cycles maximizes energy efficiency. Output leakage current is just 3mA at 120V AC and 6mA at 240V AC, preventing false load activation. Power consumption is only 160mA from the 5V backplane bus.\u003c\/p\u003e\n\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e Can this module switch DC loads?\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e No. The IC693MDL330 is designed for AC loads only at 85-264V AC, 50\/60 Hz.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e What happens if the minimum load current of 100mA is not met?\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e The output may not switch reliably or may exhibit false triggering. Add a bleed resistor across the load to increase current.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e How many outputs can operate simultaneously at 40°C?\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e Each group of 4 outputs handles 4A maximum total at 40°C. Derating applies above 40°C.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050828103812,"sku":"IC693MDL330","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC693MDL330.jpg?v=1780413150","url":"https:\/\/www.etowonauto.com\/products\/ge-fanuc-ic693mdl330-output-module-8-point-120-240v-ac","provider":"Etowon Auto","version":"1.0","type":"link"}