{"product_id":"fs-tro-0824-honeywell-safety-manager-fta-module","title":"FS-TRO-0824 Honeywell Safety Manager FTA Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eFS-TRO-0824\u003c\/strong\u003e acts as a reliable Field Termination Assembly (FTA) interface between system interconnection cables and external field wiring. This module features 8 non-safe, potential-free relay changeover contacts (NO\/NC) to manage external field devices. Integrated LEDs provide clear, real-time status indication for each channel, simplifying system diagnostics in demanding industrial environments.\u003c\/p\u003e\n\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOvercurrent Protection:\u003c\/strong\u003e Each channel contains an individual, field-replaceable 5 A time-lag fuse (Schurter 0001.2511) to isolate field faults.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Isolation:\u003c\/strong\u003e Provides 4000 V AC coil-to-contact isolation, shielding critical control logic from field voltage surges.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStreamlined Connectivity:\u003c\/strong\u003e Connects directly to redundant SDO-0824 modules via a standard system interconnection cable, reducing cabinet wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eSpecification Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e8 Output Channels (Potential-free NO\/NC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e24 V DC (Max 31 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eMax Switched Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e250 V AC \/ 300 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eMax Switched Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e5 A per channel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eFuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e5 A Time-Lag, 5x20 mm (Schurter 0001.2511)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eDimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e195 × 70 × 60 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eDIN EN Rails TS32 \/ TS35 × 7.5\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal Derating:\u003c\/strong\u003e Supports full 5 A current up to 25°C, derating linearly to 3.5 A at 70°C ambient temperature.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring Standards:\u003c\/strong\u003e Use wire diameters up to 2.5 mm² (AWG 14). Strip insulation to 7 mm and tighten terminal screws to 0.5 Nm.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFuse Safety:\u003c\/strong\u003e Always de-energize the specific loop before servicing or replacing the integrated protection fuses.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDurable Contacts:\u003c\/strong\u003e Silver-cadmium oxide (AgCdO) contact material delivers superior wear resistance under high-cycle inductive loads.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUniversal DIN Fit:\u003c\/strong\u003e Snap-on footing mechanism supports standard TS32 and TS35 DIN rails for seamless enclosure integration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLocal Diagnostics:\u003c\/strong\u003e Dedicated coil-side LEDs accelerate troubleshooting during loop tests and commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Why is the module rating limited to 5 A if the individual relays support 8 A?\u003c\/strong\u003e\u003cbr\u003e\nA1: The systemic output limit is restricted to 5 A to protect PCB traces, terminal connections, and to align with the onboard 5 AT Schurter safety fuse.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can this module mix AC and DC loads simultaneously across different channels?\u003c\/strong\u003e\u003cbr\u003e\nA2: Yes. All 8 channels feature independent potential-free contacts, allowing you to run separate AC and DC voltage sources within the maximum specified ratings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How should I handle inductive loads like heavy solenoids?\u003c\/strong\u003e\u003cbr\u003e\nA3: While the AgCdO contacts naturally resist arcing, installing an external flyback diode across inductive DC field loads will significantly extend the operational life of the relay contacts.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51864171905156,"sku":"FS-TRO-0824","price":267.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/FS-TRO-0824.jpg?v=1779004317","url":"https:\/\/www.etowonauto.com\/products\/fs-tro-0824-honeywell-safety-manager-fta-module","provider":"Etowon Auto","version":"1.0","type":"link"}