{"product_id":"fc-tsao-0220m-honeywell-fta-2-channel-output","title":"FC-TSAO-0220M Honeywell FTA 2-Channel Output","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eFC-TSAO-0220M\u003c\/strong\u003e is a high-integrity Safe Analog Output Field Termination Assembly (FTA) module. It acts as a rugged interface between the system interconnection cable (SICC-0001\/Lx) and external field wiring via secure screw terminals. Supporting two isolated 0(4)-20 mA analog output channels, this module controls field devices like valves and actuators in both safety-critical (up to SIL 3) and non-safety applications within process industries.\u003c\/p\u003e\n\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Isolation:\u003c\/strong\u003e Built-in isolation barriers safeguard upstream SAO-0220M modules from field-side electrical surges and transients up to IEC 1010 Overvoltage Category 3 standards.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Load Capacity:\u003c\/strong\u003e Supports a 40 V DC maximum voltage and a continuous 25 mA loop current per channel to drive high-impedance loads over long distances.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGas-Tight Connections:\u003c\/strong\u003e Heavy-duty screw terminals accept wires up to 2.5 mm² (AWG 14), preventing loose wiring caused by industrial machinery vibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 10px;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eFC-TSAO-0220M Specification\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eFC-TSAOH-0220M Specification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eChannels\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e2 Fully Isolated Channels\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e2 Channels with Common 0V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eSignal Range\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0-20 mA \/ 4-20 mA\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0-20 mA \/ 4-20 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eMax Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e40 V DC\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e40 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eMax Current\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e25 mA per channel\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e25 mA per channel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eWire Size\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e2.5 mm² (AWG 14)\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e2.5 mm² (AWG 14)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eDimensions\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e50 × 70 × 48 mm\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e64 × 109 × 66 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eApprovals\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eCE, TUV, UL, CSA, FM\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eCE, TUV, UL, CSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Snap onto standard TS32 or TS35 × 7.5 DIN rails. Allocate 51 mm of rail length for the TSAO module and 65 mm for the TSAOH variant.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Strip field wires to exactly 7 mm. Use a calibrated torque screwdriver to tighten terminal screws to 0.5 Nm (0.37 ft-lb).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Ground all field wiring shields at the cabinet entry panel to avoid noise interference in the 4-20 mA loop.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhy Choose This Module\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSIL 3 Compliance:\u003c\/strong\u003e Fully certified by TUV, UL, CSA, and FM for use in critical emergency shutdown (ESD) systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNative Integration:\u003c\/strong\u003e Connects perfectly with Honeywell Safety Manager platforms using standard SICC-0001\/Lx cables.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomatic Fault Diagnostics:\u003c\/strong\u003e Supports loop status monitoring to detect open-circuit and short-circuit field conditions instantly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What separates the FC-TSAO-0220M from the FC-TSAOH-0220M?\u003c\/strong\u003e\u003cbr\u003e\nA1: The standard TSAO version has fully isolated channels and a smaller footprint (50 mm width), while the TSAOH version shares a common 0V return and has a wider footprint (64 mm width).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does this unit support line monitoring for field faults?\u003c\/strong\u003e\u003cbr\u003e\nA2: Yes, when integrated with Honeywell safety controllers, it diagnoses open and short circuits across the control loop automatically.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is this module safe for hazardous area installation?\u003c\/strong\u003e\u003cbr\u003e\nA3: Yes. It carries FM and CSA approvals, allowing safe installation in Class I, Division 2 \/ Zone 2 environments when mounted inside an appropriate enclosure.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51864413667460,"sku":"FC-TSAO-0220M","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/FC-TSAO-0220M.jpg?v=1779026814","url":"https:\/\/www.etowonauto.com\/products\/fc-tsao-0220m-honeywell-fta-2-channel-output","provider":"Etowon Auto","version":"1.0","type":"link"}