{"product_id":"drl-48v480w1en-delta-lyte-ii-48v-480w-din-rail-power-supply","title":"DRL-48V480W1EN Delta Lyte II 48V 480W DIN Rail Power Supply","description":"\u003ch2 style=\"color: #003366; font-weight: bold; margin-bottom: 12px;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333;\"\u003eThe \u003cstrong style=\"color: #003366;\"\u003eDRL-48V480W1EN\u003c\/strong\u003e is a premium industrial DIN rail power supply from Delta's high-efficiency series. Engineered to deliver a stable 48V DC output at a 10A current rating, this 480W power supply features an ultra-slim form factor that maximizes cabinet space. With its robust build quality, it provides reliable, high-power density energy conversion for demanding industrial automation environments.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 20px; margin-bottom: 12px;\"\u003eKey Advantages\u003c\/h2\u003e\n\u003cul style=\"font-size: 14px; line-height: 1.5; color: #333333; padding-left: 20px; margin-bottom: 15px;\"\u003e\n    \u003cli style=\"margin-bottom: 6px;\"\u003e\n\u003cstrong\u003eReactive Load Handling:\u003c\/strong\u003e Equipped with a built-in constant current circuit that easily manages heavy inductive or capacitive reactive loads during startup surges.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 6px;\"\u003e\n\u003cstrong\u003eSlim Space-Saving Profile:\u003c\/strong\u003e The space-conscious 56mm width design permits tightly packed DIN rail mounting, significantly reducing overall enclosure sizing.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 6px;\"\u003e\n\u003cstrong\u003eExtreme Environment Operation:\u003c\/strong\u003e Engineered to withstand harsh plant floors, performing reliably across an ultra-wide temperature envelope from -40°C up to +70°C.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 6px;\"\u003e\n\u003cstrong\u003eEnergy Efficiency \u0026amp; Compliance:\u003c\/strong\u003e Optimizes power usage with reduced no-load power consumption and meets strict SEMI F47 industrial voltage sag immunity standards at 200 Vac lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 20px; margin-bottom: 12px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #003366; font-size: 14px; color: #333333;\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9; width: 35%;\"\u003eModel Designation\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003eDRL-48V480W1EN\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eManufacturer\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003eDelta Electronics\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eNominal Output Voltage\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e48 V DC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eMaximum Output Power\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e480 W\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eRated Output Current\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e10 A\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eInput Voltage Range\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003eUniversal 90...264 V AC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eOperating Temperature\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e-40°C to +70°C\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003ePhysical Footprint\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e123.6 x 56 x 116.8 mm (4.87” x 2.20” x 4.60”)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eUnit Net Weight\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e0.87 kg (1.92 lb)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eIndustry Standards\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003eSEMI F47 compliant @ 200 Vac | RoHS Compliant\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 20px; margin-bottom: 12px;\"\u003eQuick Installation Tips\u003c\/h2\u003e\n\u003cul style=\"font-size: 14px; line-height: 1.5; color: #333333; padding-left: 20px; margin-bottom: 15px;\"\u003e\n    \u003cli style=\"margin-bottom: 6px;\"\u003eSnap the unit vertically onto standard 35mm DIN rails, ensuring the input terminals face downward to promote natural cooling convention.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 6px;\"\u003eLeave a minimum recommended ventilation clearance above and below the device when integrating it adjacent to other power components inside compact panels.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 6px;\"\u003eVerify that the source AC line voltage falls within the flexible 90-264 Vac range prior to applying power to protect the internal regulatory circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 20px; margin-bottom: 12px;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 2px;\"\u003e\u003cstrong\u003eQ1: How does the constant current circuit assist with reactive loads?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #555555; margin-bottom: 10px;\"\u003eA1: When running motors, solenoids, or heavy capacitive filters, startup current spikes can trigger standard power supplies to shut down. The DRL-48V480W1EN stays operational by switching to constant current mode to sustain power delivery without entering a protection fault state.\u003c\/p\u003e\n\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 2px;\"\u003e\u003cstrong\u003eQ2: What is the significance of the SEMI F47 compliance standard?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #555555; margin-bottom: 10px;\"\u003eA2: SEMI F47 indicates that the power supply can ride through voltage sags on the utility grid without dropping its 48V DC output load, which is critical for preventing costly downtime in semiconductor and precise process automation lines.\u003c\/p\u003e\n\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 2px;\"\u003e\u003cstrong\u003eQ3: Does the unit require an external cooling fan at +70°C?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #555555; margin-bottom: 10px;\"\u003eA3: The unit is designed for natural convection cooling. While it can operate up to +70°C, typical industrial thermal management mandates output power derating above a certain temperature threshold (refer to the official manual's derating curves).\u003c\/p\u003e","brand":"Delta","offers":[{"title":"Default Title","offer_id":52336543727748,"sku":"DRL-48V480W1EN","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/DRL-48V480W1EN.jpg?v=1781878282","url":"https:\/\/www.etowonauto.com\/products\/drl-48v480w1en-delta-lyte-ii-48v-480w-din-rail-power-supply","provider":"Etowon Auto","version":"1.0","type":"link"}