{"product_id":"drf-24v480w3gba-delta-480w-multi-phase-slim-power-module","title":"DRF-24V480W3GBA Delta 480W Multi-Phase Slim Power Module","description":"\u003ch2 style=\"color: #003366; font-weight: bold; margin-bottom: 12px;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333;\"\u003eThe \u003cstrong style=\"color: #003366;\"\u003eDRF-24V480W3GBA\u003c\/strong\u003e is a highly robust, industrial-grade DIN rail power supply engineered by Delta Electronics. Designed for high-demand applications, it delivers a stabilized 24V DC output with a powerful 20A current rating (480W total output). This model features an ultra-slim, space-saving design and accommodates multi-phase electrical inputs, making it an excellent choice for complex machinery, automation panels, and rugged factory environments.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 20px; margin-bottom: 12px;\"\u003eKey Advantages\u003c\/h2\u003e\n\u003cul style=\"font-size: 14px; line-height: 1.5; color: #333333; padding-left: 20px; margin-bottom: 15px;\"\u003e\n    \u003cli style=\"margin-bottom: 6px;\"\u003e\n\u003cstrong\u003eFlexible Multi-Phase Input:\u003c\/strong\u003e Seamlessly operates on either a 3-Phase network (320-575 Vac) or a 2-Phase infrastructure (340-575 Vac) to suit various plant layouts.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 6px;\"\u003e\n\u003cstrong\u003eRethought for Charging \u0026amp; Constant Loads:\u003c\/strong\u003e Includes a built-in constant current circuit, allowing the unit to safely drive battery charging setups and heavy inductive loads without tripping.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 6px;\"\u003e\n\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e Features a high-quality conformal coating on the printed circuit board assemblies (PCBAs) to safeguard internal components against conductive dust, light moisture, and common industrial airborne pollutants.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 6px;\"\u003e\n\u003cstrong\u003eAdvanced Diagnostics \u0026amp; Surge Protection:\u003c\/strong\u003e Offers a built-in DC OK dry relay contact and LED indicator for real-time monitoring, paired with a massive surge capacity protection rating of up to 6 kV (when utilized with an appropriate SPD).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 20px; margin-bottom: 12px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #003366; font-size: 14px; color: #333333;\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9; width: 35%;\"\u003eModel Designation\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003eDRF-24V480W3GBA\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eManufacturer\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003eDelta Electronics\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eNominal Output Voltage\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e24 V DC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eMaximum Output Power\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e480 W\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eRated Output Current\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e20 A\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eInput Voltage Range\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e3 x 320-575 Vac (3-Phase) or 2 x 340-575 Vac (2-Phase)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eOperating Temperature\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003eFull load up to +55°C | Cold start capability down to -40°C\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003ePhysical Footprint\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e124 x 65 x 127.3 mm (4.88” x 2.56” x 5.01”)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eUnit Net Weight\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e1.20 kg (2.65 lb)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003ePCBA Status\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003eConformal coated tracking layers\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 20px; margin-bottom: 12px;\"\u003eQuick Installation Tips\u003c\/h2\u003e\n\u003cul style=\"font-size: 14px; line-height: 1.5; color: #333333; padding-left: 20px; margin-bottom: 15px;\"\u003e\n    \u003cli style=\"margin-bottom: 6px;\"\u003eMount the power supply vertically on a standard 35mm DIN rail to optimize the chassis' internal convective thermal dissipation.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 6px;\"\u003eWhen wiring the input terminals, ensure correct phase configuration mapping (L1, L2, L3) and firmly tighten terminal screws to minimize localized resistance.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 6px;\"\u003eConnect the built-in DC OK relay output directly to your PLC or supervisory system monitoring block for immediate remote diagnostics on line power failure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 20px; margin-bottom: 12px;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 2px;\"\u003e\u003cstrong\u003eQ1: Can the DRF-24V480W3GBA operate effectively if one incoming phase is lost?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #555555; margin-bottom: 10px;\"\u003eA1: Yes, the unit specifies an input range accommodating 2-Phase (2 x 340-575 Vac) operation. However, continuous heavy-duty loading under a missing phase should be cross-referenced with Delta’s thermal and power derating specifications to ensure longevity.\u003c\/p\u003e\n\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 2px;\"\u003e\u003cstrong\u003eQ2: What are the main benefits of a conformal-coated PCBA layer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #555555; margin-bottom: 10px;\"\u003eA2: Conformal coating applies a protective, non-conductive film over the internal electronics. This barrier safeguards delicate surface-mount components from short-circuiting or corroding when exposed to industrial dust, metallic shavings, and harsh environmental pollutants.\u003c\/p\u003e\n\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 2px;\"\u003e\u003cstrong\u003eQ3: How does the \"Cold Start at -40°C\" feature assist with outdoor installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #555555; margin-bottom: 10px;\"\u003eA3: Many standard power supplies fail to turn on or regulate voltage in extreme sub-zero conditions due to component thermal contraction. This unit is certified to safely initialize and establish a stable 24V output even at a freezing -40°C baseline.\u003c\/p\u003e","brand":"Delta","offers":[{"title":"Default Title","offer_id":52336555982980,"sku":"DRF-24V480W3GBA","price":187.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/DRF-24V480W3GBA.jpg?v=1781878562","url":"https:\/\/www.etowonauto.com\/products\/drf-24v480w3gba-delta-480w-multi-phase-slim-power-module","provider":"Etowon Auto","version":"1.0","type":"link"}