{"product_id":"delta-vfd110e43a-variable-frequency-drive-15hp-11kw","title":"Delta VFD110E43A Variable Frequency Drive 15HP 11kW","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eVFD110E43A\u003c\/strong\u003e is a high-performance, sensorless vector control AC micro drive belonging to Delta’s versatile VFD-E series. Engineered for flexible, low-horsepower applications, this 11kW (15 HP) standard variable frequency drive effectively regulates motor speed and torque. It represents a modular, IP20-rated solution designed to optimize energy efficiency and control precision for three-phase induction motors across modern industrial automation setups.\u003c\/p\u003e\n\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular Design:\u003c\/strong\u003e The VFD-E architecture supports flexible extension via plug-in cards, allowing quick installation of optional fieldbus modules and I\/O cards.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBuilt-in PLC Functions:\u003c\/strong\u003e Features integrated, user-friendly programming capabilities that handle basic logic control sequencing without requiring an external PLC.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEfficient Thermal Management:\u003c\/strong\u003e Employs a robust forced fan cooling system that maintains stable operating temperatures under heavy duty cycles.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible RFI Switch:\u003c\/strong\u003e Includes a removable RFI switch for noise suppression, making it easy to adapt the drive to various grounding setups.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 10px;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eSpecification Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eDelta Electronics\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eModel Number\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eVFD110E43A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eDrive Series\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eVFD-E Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eInput Voltage Range\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e460V AC (Three-Phase)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eMotor Capacity\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e11 kW \/ 15 HP\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eDrive Version\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eStandard Drive (A Type)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eCooling Type\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eForced Fan Cooling\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eNet Weight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e4.2 kg (9.26 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eEngineering Installation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Proximity:\u003c\/strong\u003e Install the drive vertically on a flat, vibration-free surface. Leave a minimum clearance of 50mm on the sides and 120mm above and below for optimal fan airflow.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring Safeguards:\u003c\/strong\u003e Ensure the 460V three-phase input power connects strictly to terminals R\/L1, S\/L2, and T\/L3. Connecting input power to output terminals U\/T1, V\/T2, or W\/T3 will permanently damage the unit.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding Protocols:\u003c\/strong\u003e Ground the inverter properly using the dedicated ground terminal. Keep the grounding wire as short as possible to prevent electromagnetic interference (EMI).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhy Choose This Model\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSpace-Saving Footprint:\u003c\/strong\u003e Side-by-side mounting capability reduces total enclosure panel space requirements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShared DC Bus:\u003c\/strong\u003e Connects easily in parallel with multiple drives to absorb braking energy and prevent overvoltage faults during rapid deceleration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComplete Protection Suite:\u003c\/strong\u003e Includes real-time safeguards against overcurrent, overvoltage, undervoltage, overheating, phase loss, and motor overload conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What does the \"A\" signify at the end of the VFD110E43A model number?\u003c\/strong\u003e\u003cbr\u003e\nA1: The \"A\" designates the Standard Drive version of the VFD-E series, featuring standard built-in functions without specialized hardware variations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can this VFD drive a single-phase 460V motor?\u003c\/strong\u003e\u003cbr\u003e\nA2: No. This specific model is strictly rated for 460V three-phase mains input power and must only feed three-phase induction motors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How often should the cooling fan be serviced or replaced?\u003c\/strong\u003e\u003cbr\u003e\nA3: Clean the fan regularly to prevent dust accumulation. In normal operating conditions, replace the internal cooling fan every 2 to 3 years to prevent drive overtemperature faults.\u003c\/p\u003e","brand":"Delta","offers":[{"title":"Default Title","offer_id":51867458404484,"sku":"VFD110E43A","price":106.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/VFD110E43A-1.jpg?v=1779196527","url":"https:\/\/www.etowonauto.com\/products\/delta-vfd110e43a-variable-frequency-drive-15hp-11kw","provider":"Etowon Auto","version":"1.0","type":"link"}