{"product_id":"ci858-abb-communication-interface-drivebus-protocol","title":"CI858 ABB Communication Interface DriveBus Protocol","description":"\u003ch2\u003eCI858 ABB DriveBus Communication Interface\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color:#0066cc;\"\u003eCI858 (3BSE018135R1)\u003c\/strong\u003e is a DriveBus communication interface from ABB. It connects ABB Drives and ABB Special I\/O units to the AC 800M controller via the CEX-Bus. No external power source is required. The DriveBus protocol is specifically designed for sectional drive applications in ABB rolling mill drive systems and paper machine control systems.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable width=\"100%\" border=\"0\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eArticle Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e3BSE018135R1\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eABB DriveBus\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eTransmission Speed\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e8 Mbit\/s\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eOptical\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eHot Swap\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eLine Redundancy\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eNo\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eModule Redundancy\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eNo\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eMax Units on CEX Bus\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e2\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003e24V Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e200 mA typical\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e+5 to +55 °C (+41 to +131 °F)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e-40 to +70 °C (-40 to +158 °F)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eIP20\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eCorrosion Protection\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eG3 compliant to ISA 71.04\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eMarine Certificates\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eABS, BV, DNV-GL, LR\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eCE Marking\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eRoHS Compliance\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eDIRECTIVE 2011-65-EU\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eWEEE Compliance\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eDIRECTIVE 2012-19-EU\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003ctable width=\"100%\" border=\"0\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e59 mm (2.3 in)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e185 mm (7.3 in)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e127.5 mm (5.0 in)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e700 g (1.5 lbs)\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation \u0026amp; Application\u003c\/h3\u003e\n\u003cp\u003eMount the CI858 on the CEX-Bus inside the AC 800M controller cabinet. The processor unit powers the CI858 directly through the bus connection. Connect up to 24 ABB drives to a single CI858. For multiple drives, use the NDBU branching unit to build a logical bus with physical star topology. Chain multiple branching units as needed. A maximum of two CI858 units can connect to one AC 800M controller.\u003c\/p\u003e\n\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Does CI858 require external power?\u003c\/strong\u003e\u003cbr\u003e\nA1: No. The CI858 draws power from the processor unit via the CEX-Bus. Typical consumption is 200 mA at 24V.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: How many drives can one CI858 support?\u003c\/strong\u003e\u003cbr\u003e\nA2: A single CI858 supports up to 24 ABB drives. An NDBU branching unit is required when connecting more than one drive.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What industries use the CI858?\u003c\/strong\u003e\u003cbr\u003e\nA3: Sectional drive applications including ABB rolling mill drive systems and ABB paper machine control systems.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ4: Is the CI858 suitable for marine environments?\u003c\/strong\u003e\u003cbr\u003e\nA4: Yes. It holds marine certificates from ABS, BV, DNV-GL, and LR.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51050469818500,"sku":"CI858","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CI858.jpg?v=1780154715","url":"https:\/\/www.etowonauto.com\/products\/ci858-abb-communication-interface-drivebus-protocol","provider":"Etowon Auto","version":"1.0","type":"link"}