{"product_id":"bently-nevada-3500-92-04-01-00-communication-gateway","title":"Bently Nevada 3500\/92-04-01-00 Communication Gateway","description":"\u003ch2\u003eBently Nevada 3500\/92-04-01-00 Communication Gateway (136180-01)\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong style=\"color: #1a5276;\"\u003eBently Nevada 3500\/92-04-01-00\u003c\/strong\u003e Communication Gateway collects data from 3500 rack modules via high speed internal network. Provides Ethernet and Modbus connectivity for integration with plant control systems and vibration monitoring software.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Identification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Bently Nevada\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Number:\u003c\/strong\u003e 3500\/92-04-01-00 (136180-01)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e 3500\/92 Communication Gateway\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e Made in U.S.A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eModel Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e04\u003c\/strong\u003e – Ethernet\/RS485 Modbus I\/O Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e01\u003c\/strong\u003e – Low Memory\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e – No Agency Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003cth style=\"padding: 8px 12px; border: 1px solid #ccc; text-align: left; width: 40%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 8px 12px; border: 1px solid #ccc; text-align: left; width: 60%;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eMain Board (H×W×D)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e241 × 24.4 × 242 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eI\/O Module (H×W×D)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e241 × 24.4 × 99.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e1.26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003ePower (RS232\/RS422)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e5.0 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003ePower (RS485)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e5.6 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eData Update Rate\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e\u0026lt; 1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eEthernet\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e10 Mbps, RJ-45 (10BASE-T)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eProtocols\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eTCP\/IP, Modbus\/TCP, Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e-30°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eRack Space\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e1 full-height front slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eIndicators\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOK LED:\u003c\/strong\u003e Normal operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTX\/RX LED:\u003c\/strong\u003e Active communication with rack modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCertifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFCC Part 15\u003c\/li\u003e\n\u003cli\u003eEN 61000-6-2 \/ -6-4 (EMC)\u003c\/li\u003e\n\u003cli\u003eEN 61010-1 (Electrical Safety)\u003c\/li\u003e\n\u003cli\u003eRoHS 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003eDNV GL, ABS (Maritime)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall in 3500 rack full-height front slot.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for RS485\/RS422.\u003c\/li\u003e\n\u003cli\u003eVerify Ethernet network settings before commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e What software communicates with the 3500\/92?\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e 3500 Configuration Software and 3500 Data Acquisition Software via Ethernet TCP\/IP.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e What does 04 specify in the model number?\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e Ethernet\/RS485 Modbus I\/O Module. Other options include RS232\/RS422 variants.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e Does it support Modbus TCP?\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e Yes. Modbus RTU over serial and Modbus\/TCP over Ethernet are both supported.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52539675803780,"sku":"3500\/92-04-01-00","price":149.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_92-04-01-00.jpg?v=1784468032","url":"https:\/\/www.etowonauto.com\/products\/bently-nevada-3500-92-04-01-00-communication-gateway","provider":"Etowon Auto","version":"1.0","type":"link"}