{"product_id":"bently-nevada-330130-070-12-00-proximity-sensor-cable","title":"Bently Nevada 330130-070-12-00 Proximity Sensor Cable","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003e330130-070-12-00\u003c\/strong\u003e is an industrial-grade Bently Nevada 3300 XL 8 mm Proximity Transducer Extension Cable. This 7.0-meter armored cable provides secure, low-loss signal transmission between an eddy current proximity probe and a 3300 XL Proximitor Sensor. Featuring patented FluidLoc technology, it blocks oil and process liquids from leaking out of the machine housing through the cable interior, ensuring optimal vibration and position monitoring for critical rotating machinery.\u003c\/p\u003e\n\n\u003ch2\u003eCore Features\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFluidLoc Cable Technology:\u003c\/strong\u003e Prevents internal liquid migration to protect sensitive electronics from turbine oil exposure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRugged Stainless Steel Armor:\u003c\/strong\u003e Defends the internal coaxial cores against harsh physical environments, crushing, and mechanical wear.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Connector Protector:\u003c\/strong\u003e Features heavy-duty physical connector protection designed for severe chemical and oil exposure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Pull Strength:\u003c\/strong\u003e Built to complement the patented CableLoc design, handling harsh mechanical stress without signal loss.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 6px;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 6px;\"\u003eData\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 6px;\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 6px;\"\u003e330130-070-12-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 6px;\"\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 6px;\"\u003e7.0 meters (22.9 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 6px;\"\u003e\u003cstrong\u003eCable Configuration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 6px;\"\u003eArmored FluidLoc cable with connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 6px;\"\u003e\u003cstrong\u003eTotal Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 6px;\"\u003e0.721 kg (103 g\/m \/ 1.5 oz\/ft unit weight)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 6px;\"\u003e\u003cstrong\u003eDC Core Resistance ($R_{CORE}$)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 6px;\"\u003e1.54 Ω ± 0.23 Ω (Center to Center)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 6px;\"\u003e\u003cstrong\u003eDC Jacket Resistance ($R_{JACKET}$)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 6px;\"\u003e0.46 Ω ± 0.09 Ω (Outer to Outer)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 6px;\"\u003e\u003cstrong\u003eExtension Cable Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 6px;\"\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 6px;\"\u003e\u003cstrong\u003eLinear Range Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 6px;\"\u003e2 mm (80 mils) total span (approx. −1 to −17 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 6px;\"\u003e\u003cstrong\u003eOutput Impedance \/ Supply Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 6px;\"\u003e50 Ω \/ Less than 2 mV change per volt input shift\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 6px;\"\u003e\u003cstrong\u003eSafety Approvals Code\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 6px;\"\u003e00 (Approvals not required)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eEngineering \u0026amp; Installation Guide\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTotal Weight Considerations:\u003c\/strong\u003e Factor the 0.721 kg cable weight into your mounting brackets and junction boxes to avoid strain on the probe body.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTurbine Oil Warning:\u003c\/strong\u003e Do not rely on silicone tape alone for environments exposed to turbine oil. The factory-integrated connector protector must be used to ensure loop security.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTotal Loop Matching:\u003c\/strong\u003e This 7.0m extension cable matches with a 1.0m probe to achieve an standard 8-meter system calibration against an AISI 4140 steel target.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eField Wiring Specs:\u003c\/strong\u003e Connect to monitors using 0.2 to 1.5 mm² (16 to 24 AWG) 3-conductor shielded triad cable. Keep runs under 305 meters (1,000 feet) to prevent high-frequency rolloff.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What parameters do the suffix codes -070-12-00 represent?\u003c\/strong\u003e\u003cbr\u003e\nA1: -070 defines the physical length as exactly 7.0 meters. -12 selects the armored FluidLoc design with built-in connector protectors. -00 indicates no special hazardous area certification is required for the installation zone.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Why is the FluidLoc cable option critical for turbine environments?\u003c\/strong\u003e\u003cbr\u003e\nA2: Standard coaxial cables can act as conduits under differential pressure, wicking oil or gases from inside the machine casing. The FluidLoc option seals the interior of the cable, preventing oil leaks into external housings or panels.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What voltage limits apply when connecting this cable to a Proximitor sensor loop?\u003c\/strong\u003e\u003cbr\u003e\nA3: The complete loop requires an input voltage between -17.5 Vdc and -26 Vdc (at 12 mA max). For optimum linear range performance, do not allow the operating voltage to become more positive than -23.5 Vdc.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050753785988,"sku":"330130-070-12-00","price":125.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/330130-070-12-00.jpg?v=1779977313","url":"https:\/\/www.etowonauto.com\/products\/bently-nevada-330130-070-12-00-proximity-sensor-cable","provider":"Etowon Auto","version":"1.0","type":"link"}