{"product_id":"bently-nevada-330130-040-03-00-proximitor-extension-cable-stock","title":"Bently Nevada 330130-040-03-00 Proximitor Extension Cable Stock","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eBently Nevada 330130-040-03-00\u003c\/strong\u003e operates as a high-performance 3300 XL series extension cable engineered for proximity transducer systems. This premium 4.0-meter armored cable acts as the vital electrical link connecting an 8 mm eddy current probe to a Proximitor Sensor. It accurately transmits high-frequency displacement telemetry from critical rotating machinery, such as industrial steam turbines and compressors, without signal degradation or impedance mismatches.\u003c\/p\u003e\n\n\u003ch2\u003eCore Technological Advantages\u003c\/h2\u003e\n\u003ch3\u003eSuffix Part-Number Configuration\u003c\/h3\u003e\n\u003cp\u003eThe specific model code string outlines precise structural properties engineered for immediate deployment:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e040 Cable Length Option:\u003c\/strong\u003e Provides a nominal cable length of exactly 4.0 meters (11.5 feet) for specific sensor-to-amplifier distances.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e03 Connector Option:\u003c\/strong\u003e Integrates robust stainless steel armored cabling along with a factory-installed mechanical connector protector.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e00 Approvals Option:\u003c\/strong\u003e Specifies that standard agency certification approvals are not required for the designated site installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eMechanical Armoring and Pull Strength\u003c\/h3\u003e\n\u003cp\u003eThe physical build features rugged armoring over the core, weighing 103 g\/m (total weight: 0.618 kg). The underlying architecture utilizes patented CableLoc molding methods, delivering a massive 330 N (75 lbf) pull strength to ensure the assembly withstands severe industrial stress.\u003c\/p\u003e\n\n\u003ch3\u003ePrecision DC Electrical Resistance\u003c\/h3\u003e\n\u003cp\u003eThe cable core establishes highly repeatable eddy current sensor calibrations through strictly controlled internal resistance tolerances. The center conductor (RCORE) maintains a low resistance of 0.88 ± 0.13 Ω, while the outer jacket boundary (RJACKET) measures precisely 0.26 ± 0.05 Ω.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #1a365d; color: #ffffff;\"\u003e\n      \u003cth style=\"padding: 10px; border: 1px solid #e2e8f0; text-align: left;\"\u003eSpecification Parameter\u003c\/th\u003e\n      \u003cth style=\"padding: 10px; border: 1px solid #e2e8f0; text-align: left;\"\u003eValue \/ Operational Limit\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eBently Nevada (Made in U.S.A.)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eProduct Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e330130-040-03-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eCable Type \u0026amp; Length\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eArmored Extension Cable \/ 4.0 Meters (11.5 Feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eTotal Net Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e0.618 kg (Unit Density: 103 g\/m)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eElectrical Capacitance\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eTransducer Linear Range\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e2 mm (80 mils) spanning from 0.25 to 2.3 mm (10 to 90 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eSystem Transducer Power\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eRequires -17.5 Vdc to -26 Vdc supply @ 12 mA maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eSystem Output Resistance\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e50 Ω\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eField Wiring Limits\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e0.2 to 1.5 mm² (16 to 24 AWG) up to 305 meters max\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eHumidity Resistance\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e\u0026lt; 3% Average Scale Factor (ASF) drift at 93% RH (IEC 68-2-3)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eEngineering Installation Guide\u003c\/h2\u003e\n\u003ch3\u003eProbe Connection and Oil Protection\u003c\/h3\u003e\n\u003cp\u003eEach cable kit includes premium silicone tape. However, do not apply silicone tape if the active probe-to-extension connection faces exposure to aggressive turbine oil. Always deploy the integrated mechanical connector protector in these spaces to isolate terminal electrical links.\u003c\/p\u003e\n\n\u003ch3\u003eStandard Operational Gap Reference\u003c\/h3\u003e\n\u003cp\u003eFor nominal calibration and maximum measurement linearity across the 2 mm span, gap the 8 mm eddy current probe exactly at 1.27 mm (50 mils) from the target. Ensure the machine shaft target consists of AISI 4140 steel to maintain strict loop output accuracy.\u003c\/p\u003e\n\n\u003ch3\u003eField Wiring Configurations\u003c\/h3\u003e\n\u003cp\u003eConnect the Proximitor Sensor to monitors using 3-conductor shielded triad cable with tinned wiring. Keep the continuous cable run below the maximum physical limit of 305 meters (1,000 feet) to prevent signal roll-off at elevated machine vibration frequencies.\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003ch3\u003ePremium Mechanical Protection\u003c\/h3\u003e\n\u003cp\u003eThe 03 armored steel jacket shields delicate inner insulation layers from high-velocity impact, sharp debris, and aggressive pulling handling common during maintenance turnarounds.\u003c\/p\u003e\n\n\u003ch3\u003eExcellent Temperature and Humidity Stability\u003c\/h3\u003e\n\u003cp\u003eTested in strict compliance with the IEC 68-2-3 standard for 56 continuous days inside 93% relative humidity chambers, the internal materials demonstrate under a 3% change in Average Scale Factor (ASF).\u003c\/p\u003e\n\n\u003ch3\u003ePatented Structural Durability\u003c\/h3\u003e\n\u003cp\u003eCombining the proprietary TipLoc body molding with the CableLoc termination method secures components against a pull force up to 330 N, eliminating standard cable detachment errors inside harsh machinery housings.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What happens if the system input supply voltage rises more positive than -23.5 Vdc?\u003c\/strong\u003e\u003cbr\u003e\nA1: Operating the transducer system with a power level more positive than -23.5 Vdc can degrade performance, leading to a significantly reduced linear range across the AISI 4140 steel target.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Why are the core conductor and jacket resistances of this 4.0m cable controlled so tightly?\u003c\/strong\u003e\u003cbr\u003e\nA2: RCORE (0.88 ± 0.13 Ω) and RJACKET (0.26 ± 0.05 Ω) are strictly tuned to ensure complete interchangeability with standard 3300 XL Proximitors without requiring a complete hardware recalibration.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Does the cable shield internal media layers against pressure differentials?\u003c\/strong\u003e\u003cbr\u003e\nA3: The extension cable handles signal routing, while the companion 3300 XL 8 mm probe housing is engineered with a built-in Viton O-ring to seal internal differential pressure between the probe tip and the machine case.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050392289412,"sku":"330130-040-03-00","price":146.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/330130-075-00-00-2_3a425b5e-fca0-498e-87be-8d736eaa04dd.jpg?v=1779803636","url":"https:\/\/www.etowonauto.com\/products\/bently-nevada-330130-040-03-00-proximitor-extension-cable-stock","provider":"Etowon Auto","version":"1.0","type":"link"}