{"product_id":"ai910n-abb-s900-analog-input-module-3kde175513l9100","title":"AI910N ABB S900 Analog Input Module 3KDE175513L9100","description":"\u003ch2 style=\"color: #003366; font-weight: bold; margin-bottom: 12px;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333;\"\u003eThe \u003cstrong style=\"color: #003366;\"\u003eAI910N\u003c\/strong\u003e is a 4-channel analog input module from the ABB S900 I\/O series, designated under article number 3KDE175513L9100. It processes standard 4...20 mA loop-powered signals from 2-wire transmitters, offering dedicated field instrument data acquisition for non-hazardous industrial installations.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 20px; margin-bottom: 12px;\"\u003eKey Advantages\u003c\/h2\u003e\n\u003cul style=\"font-size: 14px; line-height: 1.5; color: #333333; padding-left: 20px; margin-bottom: 15px;\"\u003e\n    \u003cli style=\"margin-bottom: 6px;\"\u003e\n\u003cstrong\u003eLoop-Powered Design:\u003c\/strong\u003e Suppresses external power wiring complexities by utilizing the instrumentation current loop.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 6px;\"\u003e\n\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e Certified under ISA-S71.04 G3 standards to survive highly corrosive and aggressive atmospheres.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 6px;\"\u003e\n\u003cstrong\u003eSlim Form Factor:\u003c\/strong\u003e The compact 20 mm width maximizes critical rail space inside control enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 20px; margin-bottom: 12px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #003366; font-size: 14px; color: #333333;\"\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9; width: 35%;\"\u003eModel \/ Article No.\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003eAI910N \/ 3KDE175513L9100\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eI\/O Series\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003eS900 I\/O\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eChannel Configuration\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e4 Channels\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eSignal \u0026amp; Power Type\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e4...20 mA loop-powered for 2-wire transmitters\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eDimensions (W x D x H)\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e20 mm x 104 mm x 104 mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eNet Weight\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e0.13 kg (0.29 lbs.)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eThermal Limits\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003e-20°C to 60°C operational range\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eClimatic Tolerance\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003eMaximum 93% RH ±3% at 40°C\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eSafety Profiles\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003eNon-Intrinsic Safety | For use in safe (non-hazardous) areas\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px; font-weight: bold; background-color: #f9f9f9;\"\u003eRegulatory Compliance\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #003366; padding: 6px;\"\u003eCE | RoHS Directive 2011\/65\/EU | WEEE 2012\/19\/EU\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 20px; margin-bottom: 12px;\"\u003eQuick Installation Tips\u003c\/h2\u003e\n\u003cul style=\"font-size: 14px; line-height: 1.5; color: #333333; padding-left: 20px; margin-bottom: 15px;\"\u003e\n    \u003cli style=\"margin-bottom: 6px;\"\u003eVerify that the installation field remains designated as a safe, non-hazardous area prior to mounting.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 6px;\"\u003eConfirm your loop instrumentation matches 2-wire architecture to leverage the module's passive line-powering structure.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 6px;\"\u003eMaintain proper vertical ventilation spacing inside the cabinet to prevent thermal accumulation outside the -20°C to 60°C specification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 20px; margin-bottom: 12px;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 2px;\"\u003e\u003cstrong\u003eQ1: Does the AI910N support intrinsic safety for hazardous locations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #555555; margin-bottom: 10px;\"\u003eA1: No. This specific model features a non-intrinsically safe architecture and is built exclusively for use in safe, non-hazardous field areas.\u003c\/p\u003e\n\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 2px;\"\u003e\u003cstrong\u003eQ2: What protection does the ISA-S71.04 G3 classification offer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #555555; margin-bottom: 10px;\"\u003eA2: The G3 compliance ensures the internal circuits are protected against severe corrosion caused by airborne contaminants like hydrogen sulfide and sulfur dioxide.\u003c\/p\u003e\n\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 2px;\"\u003e\u003cstrong\u003eQ3: Does this module require an external voltage supply connection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #555555; margin-bottom: 10px;\"\u003eA3: No. The channel circuitry runs directly off the transmitter current loops, removing the need for auxiliary power line hookups.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51050496262276,"sku":"AI910N","price":169.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/ABB_AI910N-1.jpg?v=1781352299","url":"https:\/\/www.etowonauto.com\/products\/ai910n-abb-s900-analog-input-module-3kde175513l9100","provider":"Etowon Auto","version":"1.0","type":"link"}