{"product_id":"abb-tc514v2-3bse013281r1-af100-communication-module","title":"ABB TC514V2 3BSE013281R1 AF100 Communication Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe ABB TC514V2 (3BSE013281R1) is a high-performance Advant Fieldbus 100 (AF100) twisted pair to optical fiber repeater for Advant OCS systems. It converts electrical twisted pair signals into optical signals to provide electrical isolation and extend network distance. This module prevents signal degradation and safeguards data integrity in harsh, high-EMI industrial environments such as power plants and chemical facilities.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003ch3\u003eCore Technical Advantages\u003c\/h3\u003e\n\u003cp\u003eThis module features 50V rated isolation to eliminate ground loops and voltage spikes. It maintains deterministic, real-time 250 Kbps AF100 protocol performance for time-critical applications. By transitioning copper cabling to optical fiber, it overcomes physical distance limits. The hardware runs efficiently on a standard 24V DC power supply with a maximum 5W power consumption footprint.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 15px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background-color: #f2f7fc;\"\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px; width: 35%;\"\u003eProduct ID\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003e3BSE013281R1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eABB Type Designation\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003eTC514V2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f2f7fc;\"\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003eCommunication Module \/ Repeater Modem\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eNetwork Interface\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003eAdvant Fieldbus 100 (AF100)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f2f7fc;\"\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eMedia Conversion\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003eTwisted Pair (Copper) to Optical Fiber\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eData Transmission Rate\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003e250 Kbps (Standard AF100 Speed)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f2f7fc;\"\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eInput Power Supply\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003e24V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eRated Isolation Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003e50 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f2f7fc;\"\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003ePower Consumption\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003eMax 5 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003e0°C to +55°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f2f7fc;\"\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003e122 mm x 58 mm x 168 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; font-weight: bold; padding: 10px;\"\u003eNet Weight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #a9bccc; padding: 10px;\"\u003e0.34 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003ch3\u003eMechanical Mounting and Cooling\u003c\/h3\u003e\n\u003cp\u003eMount vertically on a standard DIN rail inside an enclosure. Maintain 50 mm clearance above and below the unit for natural convection cooling. Do not mount directly next to high-heat sources like VFDs.\u003c\/p\u003e\n\u003ch3\u003eCabling and Connectivity\u003c\/h3\u003e\n\u003cp\u003eMaintain a minimum 75 mm bending radius for the AF100 copper cables. Use multi-mode fiber optic cables with ST connectors. Clean all fiber faces with isopropyl alcohol prior to insertion to maximize link budget performance.\u003c\/p\u003e\n\u003ch3\u003ePower and Grounding\u003c\/h3\u003e\n\u003cp\u003eConnect the 24V DC source using shielded wire. Tie the functional earth terminal directly to the enclosure ground bus via a low-impedance copper strap to prevent noise.\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003ch3\u003eSignal Integrity \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp\u003eBy shifting communication to optical fiber, the TC514V2 eliminates EMI and RFI vulnerabilities over extended distances. It offers seamless integration within the ABB Advant OCS network architecture, acting as a transparent, plug-and-play bridge without software modifications.\u003c\/p\u003e\n\u003ch3\u003eIndustrial Durability\u003c\/h3\u003e\n\u003cp\u003eThe rugged solid-state design provides low thermal generation and an optimized Mean Time Between Failures (MTBF), ensuring reliable, non-stop operation in critical, 24\/7 continuous processes.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Why is the transfer rate 250 Kbps instead of 1 Gbps?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: The module serves the deterministic AF100 protocol, which is rate-limited to 250 Kbps for timing precision. Automated databases frequently list generic 1 Gbps IT network speeds by mistake.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can I connect single-mode fiber optic cables to this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: No. The TC514V2 is optimized specifically for multi-mode fiber optic cabling. Using single-mode fiber results in severe insertion loss and signal failure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How do the diagnostic LEDs simplify troubleshooting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Front LEDs show real-time status for power and active copper\/fiber bus traffic. A dark optical LED indicates a link fault or fiber breakage, isolating network issues instantly.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51050874732676,"sku":"3BSE013281R1","price":167.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3BSE013281R1.jpg?v=1781958621","url":"https:\/\/www.etowonauto.com\/products\/abb-tc514v2-3bse013281r1-af100-communication-module","provider":"Etowon Auto","version":"1.0","type":"link"}