{"product_id":"abb-3bse021439r1-s800-module-isa-s71-04-g3-corrosion-rated","title":"ABB 3BSE021439R1 S800 Module ISA-S71.04 G3 Corrosion Rated","description":"\u003ch2 style=\"color: #333333;\"\u003eABB TB846 3BSE021439R1 S800 Mechanical Module\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color: #333333;\"\u003eABB TB846 3BSE021439R1\u003c\/strong\u003e is a mechanical module from the S800 series. Features IP20 protection with corrosion resistance per ISA-S71.04 G3. Certified for hazardous locations including ATEX Zone 2 and C1 Div 2. Weight: 0.18 kg (0.40 lbs).\u003c\/p\u003e\n\u003ch3 style=\"color: #333333;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px; border: 1px solid #333333;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eTB846 3BSE021439R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eMechanics S800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e43 × 31.5 × 186 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e0.18 kg (0.40 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eIP20, IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eCorrosion Protection\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eISA-S71.04: G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e0°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e-25°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e5% to 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003ePollution Degree\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eDegree 2, IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eElectrical Safety\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eIEC 61131-2, UL 61010-1, UL 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eHazardous Location\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eC1 Div 2, C1 Zone 2 (cULus), ATEX Zone 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eMarine Certifications\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eABS, BV, DNV, LR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eEMC Compliance\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eEN 61000-6-4, EN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eClass I Equipment\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eEarth-protected (IEC 61140)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"color: #333333;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIP20 protection per IEC 60529\u003c\/li\u003e\n\u003cli\u003eCorrosion resistance ISA-S71.04 G3\u003c\/li\u003e\n\u003cli\u003eATEX Zone 2 and C1 Div 2 certified for hazardous areas\u003c\/li\u003e\n\u003cli\u003eMarine certifications: ABS, BV, DNV, LR\u003c\/li\u003e\n\u003cli\u003eEMC compliant per EN 61000-6-4 and EN 61000-6-2\u003c\/li\u003e\n\u003cli\u003eEarth-protected Class I equipment\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range 0°C to +55°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #333333;\"\u003eInstallation Guidelines (Field Engineer Notes)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Install in S800 rack or panel. Ensure adequate clearance for airflow. IP20 rating requires installation in a protected enclosure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e Class I equipment requires earth connection. Connect protective earth terminal to panel ground before energizing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area:\u003c\/strong\u003e ATEX Zone 2 and C1 Div 2 certified. Verify area classification matches certification before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature:\u003c\/strong\u003e Operating range 0°C to +55°C. Ensure cabinet ventilation maintains temperature within limits.\u003c\/p\u003e\n\u003ch3 style=\"color: #333333;\"\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1. What hazardous area certifications does the TB846 hold?\u003c\/strong\u003e\u003cbr\u003eA1. The module is certified for C1 Div 2, C1 Zone 2 (cULus), and ATEX Zone 2 hazardous locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2. What is the protection class of this module?\u003c\/strong\u003e\u003cbr\u003eA2. The module is rated IP20 per IEC 60529, suitable for installation in protected enclosures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3. What marine certifications does this module have?\u003c\/strong\u003e\u003cbr\u003eA3. The module holds ABS, BV, DNV, and LR marine certifications for shipboard applications.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51047936426116,"sku":"3BSE021439R1","price":157.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3BSE021439R1ABB-1.jpg?v=1790826262","url":"https:\/\/www.etowonauto.com\/products\/abb-3bse021439r1-s800-module-isa-s71-04-g3-corrosion-rated","provider":"Etowon Auto","version":"1.0","type":"link"}