{"product_id":"3bse022464r1-abb-tb842-optical-modulebus-communication-interface","title":"3BSE022464R1 ABB TB842 Optical ModuleBus Communication Interface","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color:#0066CC;\"\u003eABB TB842 3BSE022464R1\u003c\/strong\u003e is a ModuleBus optical communication port for ABB S800 I\/O and System 800xA. It provides high-speed fiber optic connection between CI801\/CI840\/CI840A controllers and TB820\/TB840 ModuleBus modems. Supports both simplex (ring) and duplex (line) optical configurations. Weight: 90 g.\u003c\/p\u003e\n\n\u003ch2\u003eCore Advantages\u003c\/h2\u003e\n\u003ch3\u003eHigh-Speed Optical Communication\u003c\/h3\u003e\n\u003cp\u003e10 Mbit\/s data transmission at 650 nm wavelength. Fiber optic link provides immunity to electromagnetic interference.\u003c\/p\u003e\n\n\u003ch3\u003eFlexible Topology Support\u003c\/h3\u003e\n\u003cp\u003eSimplex configuration connects nodes in a ring. Duplex configuration connects nodes in a row. Adapts to different network requirements.\u003c\/p\u003e\n\n\u003ch3\u003eFull Redundancy \u0026amp; Hot Swap\u003c\/h3\u003e\n\u003cp\u003eModule redundancy and line redundancy supported. Hot swap capability allows replacement without system shutdown.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; font-size:13px;\"\u003e\n  \u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth style=\"padding:5px; border:1px solid #ddd; text-align:left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding:5px; border:1px solid #ddd; text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eTB842\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eArticle Number\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003e3BSE022464R1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eType\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eModuleBus Optical Port\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eProtocol\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eModuleBus (optical)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eCompatible Controllers\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eCI801, CI840\/CI840A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eConnector Type\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eAgilent Versatile Link\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eMax Data Rate\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003e10 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eWavelength\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003e650 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eModule Redundancy\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eLine Redundancy\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eHot Swap\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003e20 mA (typical, 24V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003e0.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eOperating Temp (Horizontal)\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003e55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eOperating Temp (Vertical)\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003e40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003e-40°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003e5–95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eDimensions (W×H×D)\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003e17.6 × 56.7 × 42.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003e90 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eVertical or Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eCE Marking\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eSafety Standards\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eEN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eHazLoc Certifications\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003ecULus Class I Zone 2, ATEX Zone 2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eMarine Certificates\u003c\/td\u003e\n\u003ctd style=\"padding:5px; border:1px solid #ddd;\"\u003eABS, BV, DNV-GL, LR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation Tips\u003c\/h2\u003e\n\u003ch3\u003eMounting\u003c\/h3\u003e\n\u003cp\u003eSupports vertical or horizontal mounting. Vertical mounting limits max operating temperature to 40°C.\u003c\/p\u003e\n\n\u003ch3\u003eFiber Optic Connection\u003c\/h3\u003e\n\u003cp\u003eUse Agilent Versatile Link connectors with plastic or HCS fiber. For simplex configuration, connect nodes in a ring. For duplex, connect in a row.\u003c\/p\u003e\n\n\u003ch3\u003eHot Swap\u003c\/h3\u003e\n\u003cp\u003eModule can be replaced without system shutdown. Verify redundancy status before replacement.\u003c\/p\u003e\n\n\u003ch2\u003eWhy Choose ABB TB842?\u003c\/h2\u003e\n\u003cp\u003eHigh-speed 10 Mbit\/s optical communication. Full module and line redundancy. Hot swap support for minimal downtime. Certified for hazardous areas and marine applications. Compact 90g design.\u003c\/p\u003e\n\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What controllers are compatible with the TB842?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e CI801 and CI840\/CI840A controllers. Connect via TB806 for CI801 or via TU847\/TB806 for CI840\/CI840A.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: What is the maximum data transmission speed?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e 10 Mbit\/s over fiber optic cable at 650 nm wavelength.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What is the operating temperature limit for vertical mounting?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e 40°C for vertical mounting, compared to 55°C for horizontal mounting.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51047936393348,"sku":"3BSE022464R1","price":176.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3BSE022464R1_ABB.jpg?v=1790826723","url":"https:\/\/www.etowonauto.com\/products\/3bse022464r1-abb-tb842-optical-modulebus-communication-interface","provider":"Etowon Auto","version":"1.0","type":"link"}