{"product_id":"1794-if4i-allen-bradley-flex-i-o-4-channel-isolated-analog-input-module","title":"1794-IF4I Allen-Bradley Flex I\/O 4-Channel Isolated Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003e1794-IF4I\u003c\/strong\u003e is an authentic, industrial-grade Isolated Analog Input Module within Allen-Bradley’s benchmark \u003cstrong\u003eFlex I\/O\u003c\/strong\u003e distributed automation ecosystem. Engineered to monitor critical instrumentation signals in environments prone to heavy electrical noise, this module provides 4 independently isolated input channels. Each channel can be individually configured to track high-accuracy voltage ($\\pm10\\text{V}$) or current ($4\\text{ to }20\\text{mA}$) loops. With an ultra-lightweight, sub-fractional chassis footprint weighing approximately \u003cstrong\u003e0.2 lbs (approx. 90 grams)\u003c\/strong\u003e, this modular industrial component enables point-of-application signal processing right at your machines, eliminating long, interference-prone field wiring runs back to the main enclosure.\u003c\/p\u003e\n\n\u003ch3\u003eCore Technical Advantages\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChannel-to-Channel Galvanic Isolation:\u003c\/strong\u003e Provides a robust 120 Volts continuous isolation barrier between input loops. This prevents unpredictable ground-loop currents and cross-channel electrical noise from disrupting the precision of your instrumentation feedback.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePremium 16-Bit Resolution Structure:\u003c\/strong\u003e Features exceptional analog-to-digital translation granularity, processing 16 bits across unipolar ranges and 15 bits plus sign for bipolar ranges. This yields ultra-sharp steps down to 0.156 mV for voltage or 0.320 μA per digital count for current loops.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExceptional Noise Attenuation:\u003c\/strong\u003e Outfitted with high-tier filtering circuitry delivering a Common Mode Rejection Ratio (CMRR) of 100 dB alongside standard noise rejection of 60 dB, stabilizing readings near heavy variable frequency drives and high-power switchgear.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eParameter Attribute\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eFactory Specification Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eBrand \/ Manufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eProduct Model \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e1794-IF4I\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eIsolated Analog Input Module (4 Channels)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eSignal Configurations\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eCurrent: 4 to 20 mA | Voltage: ±10 Volts DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eAnalog Resolution Step\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eVoltage: 0.156 mV (Unipolar) \/ 0.313 mV (Bipolar) per count \u003cbr\u003e Current: 0.320 μA (Unipolar) \/ 0.640 μA (Bipolar) per count\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eOverall System Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e±0.1% of Full Scale value (Temperature drift: 10 ppm\/°C)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eExternal Supply Input\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e24V DC Nominal (Acceptable Range: 19.0 to 31.2V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eModule Power Projections\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eFlexbus Draw: 50 mA | Power Consumption: 1.5 Watts Max\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eSustained Isolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e120 Volts Continuous barrier protection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eModule Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eApprox. 0.2 lbs (0.09 kg) (Excludes base weight)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eEnvironmental Stress Limits\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eOperating Shock: 30g | Vibration Resistance: 5g @ 10 to 500 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eOperating Ambient Limits\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e0 to 55°C (32 to 131°F) | Storage: -40 to 85°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation \u0026amp; Field Wiring Guide\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Base Matching:\u003c\/strong\u003e The 1794-IF4I module does not include built-in terminal block screws. It must be paired with an approved terminal base unit. It is fully compatible with the \u003cstrong\u003e1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB3T, 1794-TB3TS\u003c\/strong\u003e, and \u003cstrong\u003e1794-TBN\u003c\/strong\u003e base configurations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChannel Wiring \u0026amp; Response Optimization:\u003c\/strong\u003e Wire input loops carefully to match your targeted parameter mode (Voltage vs Current terminals). The hardware boasts a fast 10 ms step response window; always plan your controller PID loop execution and diagnostic scan intervals around this 10 ms analog sampling speed.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCrucial System Warm-up Interval:\u003c\/strong\u003e For high-precision processes or thermal loop calibrations, allow the 1794-IF4I a full 30-minute electrical warm-up window after power-up. This ensures internal reference voltages and thermal points stabilize completely, guaranteeing the rated ±0.1% accuracy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eEngineering Reliability Matrix\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Mechanical Resilience:\u003c\/strong\u003e Engineered to thrive in harsh environments. The module is rated to withstand severe physical shock events up to 30g and sustained physical vibrations of 5g up to 500 Hz without experiencing internal component dislocation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply Smoothing:\u003c\/strong\u003e The internal DC power filtering section is built to accept fluctuations and electrical noise within the 19.0 to 31.2V DC window, easily handling up to 5% AC ripple on the supply line without drifting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the operational difference between the unipolar and bipolar resolution ranges?\u003c\/strong\u003e\u003cbr\u003e\nA1: Unipolar configuration utilizes the full 16-bit array to resolve zero-to-positive signals (such as 4-20mA or 0-10V). Bipolar mode assigns 15 bits to represent signal value and uses the 16th bit as a positive\/negative directional sign indicator, allowing accurate tracking of alternating spans like $\\pm10\\text{V}$.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Why is channel isolation so important compared to non-isolated input modules?\u003c\/strong\u003e\u003cbr\u003e\nA2: Non-isolated units share a common electrical ground path across their input circuits. If your field sensors are grounded at different locations across the plant floor, minor differences in ground potential can create ground loops. The 1794-IF4I features a 120V continuous galvanic isolation barrier on every channel, completely blocking these loop currents and protecting your data from corruption.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Does the 1794-IF4I module draw its field-side sensor power from the Flexbus?\u003c\/strong\u003e\u003cbr\u003e\nA3: No. The Flexbus path exclusively supplies 50 mA of low-voltage logic power to run the backplane interface. The power required to drive the analog circuitry and process input loops must be supplied externally via the nominal 24V DC field terminal connections.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51047662321796,"sku":"1794-IF4I","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1794-IF4I-1.jpg?v=1780582883","url":"https:\/\/www.etowonauto.com\/products\/1794-if4i-allen-bradley-flex-i-o-4-channel-isolated-analog-input-module","provider":"Etowon Auto","version":"1.0","type":"link"}