{"product_id":"valve-positioner-abb-v18345-1010520001","title":"Valve Positioner ABB V18345-1010520001","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color:#0b5ed7;\"\u003eABB V18345-1010520001\u003c\/strong\u003e is an electro-pneumatic valve positioner from the TZIDC series, built for precise control of pneumatic actuators on large rotary machinery. It converts a 4–20 mA control signal into a proportional air output, achieving 0.5% linearity and ±0.2% repeatability. The non-contact position sensor eliminates mechanical wear, delivering stable performance in turbine, compressor, and process valve applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003ch3\u003eCore Hardware\u003c\/h3\u003e\n\u003cp\u003eThe positioner uses a piezoresistive pressure sensor for air output feedback and a Hall-effect sensor for valve stem position. The HART protocol enables remote calibration and diagnostics without breaking the air loop. A local LCD and push-buttons allow on-site setup, zero\/span adjustment, and fault readout.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e4–20 mA (HART)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Supply\u003c\/td\u003e\n\u003ctd\u003e1.4–6.0 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Consumption\u003c\/td\u003e\n\u003ctd\u003e≤0.03 kg\/h (steady state)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e±0.5% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e±0.2% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePneumatic Ports\u003c\/td\u003e\n\u003ctd\u003e1\/4\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Entry\u003c\/td\u003e\n\u003ctd\u003eM20×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eAluminum, powder-coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003cp\u003eMount the positioner rigidly on the actuator yoke and verify the feedback lever travels 0–100% without binding. Set the air supply to 1.4 bar minimum; below this, the output may not reach full stroke. Keep cable bend radius above 50 mm and route signal wiring away from VFD cables. For explosive atmospheres, confirm the certification label matches the zone classification before energizing.\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe TZIDC platform tolerates supply air contaminated with oil and dust, reducing downtime in dirty plant environments. The aluminum housing resists corrosion in coastal and chemical plants. HART diagnostics report valve signature data, helping maintenance teams plan repairs before a trip occurs. The unit drops into existing 4–20 mA loops without extra wiring.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How do I verify the positioner is calibrated correctly?\u003c\/strong\u003e\u003cbr\u003e\nA1: Apply 4 mA and confirm the valve reaches 0% stroke; apply 20 mA and confirm 100%. Check the LCD readout matches the actual stem position within ±0.5%.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What does the 1010520001 suffix indicate?\u003c\/strong\u003e\u003cbr\u003e\nA2: It defines the analog HART input, double-acting output, IP65 aluminum housing, and standard temperature range. Confirm against the nameplate before ordering spares.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can this unit replace an older TZIDC positioner?\u003c\/strong\u003e\u003cbr\u003e\nA3: Yes, it shares the same mounting footprint and 4–20 mA interface. Verify the pneumatic port size and cable entry match the existing installation.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":68151646388356,"sku":"V18345-1010520001","price":205.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/V18345-1010520001.jpg?v=1795242666","url":"https:\/\/www.etowonauto.com\/pl\/products\/valve-positioner-abb-v18345-1010520001","provider":"Etowon Auto","version":"1.0","type":"link"}