{"product_id":"spaj142c-aa-abb-overcurrent-earth-fault-relay-0-2-1-0a-50-60hz","title":"SPAJ142C-AA ABB Overcurrent Earth-Fault Relay 0.2-1.0A 50\/60Hz","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eSPAJ142C-AA\u003c\/strong\u003e is a combined overcurrent and earth-fault protection relay manufactured by ABB. Operating across a wide auxiliary supply voltage of \u003cstrong style=\"color: #0056b3;\"\u003e110-240 V AC\/DC\u003c\/strong\u003e (50\/60 Hz), this compact protective relay features an adjustable current setting range of \u003cstrong style=\"color: #0056b3;\"\u003e0.2 to 1.0 A\u003c\/strong\u003e and adjustable time delay settings from 0.1 s to 10 s. Measuring \u003cstrong style=\"color: #0056b3;\"\u003e45 mm x 90 mm x 100 mm\u003c\/strong\u003e with a net weight of \u003cstrong style=\"color: #0056b3;\"\u003e1.10 lbs (0.5 kg)\u003c\/strong\u003e, it incorporates flexible earth-fault sensitivity settings from 10 to 300 mA to ensure selective isolation of power distribution faults.\u003c\/p\u003e\n\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual Protection Capabilities:\u003c\/strong\u003e Combines phase overcurrent and sensitive earth-fault detection within a single compact module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUniversal Power Supply:\u003c\/strong\u003e Accepts a wide auxiliary operating voltage range from 110 to 240 V AC\/DC for versatile panel integration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdjustable Timing \u0026amp; Sensitivity:\u003c\/strong\u003e Offers programmable time delays (0.1 to 10 s) and earth-fault thresholds (10 to 300 mA) for precise trip coordination.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Reliability:\u003c\/strong\u003e Engineered for an MTBF exceeding 100,000 hours in harsh industrial environments (-20 °C to +60 °C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eSpecification Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eManufacturer \u0026amp; Brand\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eABB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eProduct Model \/ Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eSPAJ142C-AA (Overcurrent and Earth-Fault Relay)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eRated Operating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e110 - 240 V AC\/DC (50 \/ 60 Hz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eCurrent Setting Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0.2 - 1.0 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eTime Delay Settings\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0.1 s to 10 s (Adjustable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eEarth-Fault Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e10 to 300 mA (Adjustable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eOutput Contact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e1 NO \/ 1 NC (Changeover Contact)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003ePhysical Dimensions \u0026amp; Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e45 mm x 90 mm x 100 mm; Net Mass: 1.10 lbs (0.5 kg)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eProtection \u0026amp; Operating Temp\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eIP20 Protection Level; -20 °C to +60 °C (-4 °F to +140 °F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eReliability Standard\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eMTBF \u0026gt; 100,000 Hours\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eIndustrial Solutions\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSubstation Feeder Protection:\u003c\/strong\u003e Protects radial distribution feeders against phase overcurrents and ground leakage faults.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Motor Protection:\u003c\/strong\u003e Monitors incoming feeder lines for large high-voltage induction motors to prevent thermal damage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTransformer Earth-Fault Monitoring:\u003c\/strong\u003e Serves as secondary backup protection for power transformers in distribution switchgear networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWiring \u0026amp; Installation\u003c\/h2\u003e\n\u003ch3\u003eAuxiliary Power \u0026amp; Circuit Isolation\u003c\/h3\u003e\n\u003cp\u003eIsolate main distribution breakers and verify de-energization of secondary CT circuits before mounting or wiring the SPAJ142C-AA relay.\u003c\/p\u003e\n\n\u003ch3\u003ePanel Mounting\u003c\/h3\u003e\n\u003cp\u003eMount the 0.5 kg relay securely inside an IP20 or higher protective control cabinet, preserving space around its 45 x 90 x 100 mm frame for wiring access and heat dissipation across -20 °C to +60 °C operating temperatures.\u003c\/p\u003e\n\n\u003ch3\u003eCT \u0026amp; Contact Connections\u003c\/h3\u003e\n\u003cp\u003eWire current transformer (CT) secondary leads to the overcurrent and earth-fault input terminals, ensuring 1 NO\/1 NC changeover trip contacts are wired correctly to the circuit breaker trip coil.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning Test\u003c\/h3\u003e\n\u003cp\u003eApply 110-240 V AC\/DC auxiliary power, adjust pickup thresholds (0.2-1.0 A) and time delays (0.1-10 s), and execute secondary injection testing prior to placing in service.\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact Enclosure:\u003c\/strong\u003e Space-saving 45x90x100 mm footprint permits high-density panel layout in retrofit switchboards.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWide Operational Margin:\u003c\/strong\u003e Robust IP20 housing and extended MTBF (\u0026gt;100,000 hours) minimize maintenance intervention.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVersatile Trip Interfacing:\u003c\/strong\u003e Changeover output contacts ensure direct compatibility with a wide range of trip circuit topologies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What are the current setting range and earth-fault sensitivity for SPAJ142C-AA?\u003c\/strong\u003e\u003cbr\u003e\nA1: Overcurrent setting ranges from 0.2 to 1.0 A, while earth-fault sensitivity is adjustable between 10 and 300 mA.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: What is the auxiliary operating voltage for this ABB relay?\u003c\/strong\u003e\u003cbr\u003e\nA2: It operates on a rated voltage of 110-240 V AC\/DC at 50\/60 Hz.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What are the physical dimensions and component weight?\u003c\/strong\u003e\u003cbr\u003e\nA3: Measures 45 mm x 90 mm x 100 mm with a net weight of 1.10 lbs (0.5 kg).\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51050508222596,"sku":"SPAJ142C-AA","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/SPAJ142C-AAABB.jpg?v=1795346440","url":"https:\/\/www.etowonauto.com\/pl\/products\/spaj142c-aa-abb-overcurrent-earth-fault-relay-0-2-1-0a-50-60hz","provider":"Etowon Auto","version":"1.0","type":"link"}