{"product_id":"mtl5015-dual-solid-state-interface-mtl-instruments","title":"MTL5015 Dual Solid-State Interface - MTL Instruments","description":"\u003ch2\u003e\u003cstrong\u003eMTL5015 Dual Channel Solid-State Interface\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eMTL5015\u003c\/strong\u003e from MTL Instruments provides dual-channel control of solid-state outputs in safe areas from hazardous area switches and proximity detectors. \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eMTL Instruments\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e\u003cstrong\u003eMTL5015\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eDual Channel Solid-State Interface\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eTwo independent channels\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Type:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eFloating solid-state\u003c\/span\u003e for logic circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eDC to 5kHz\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Weight:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e110g lightweight design\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHazardous Area Certification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitch Location:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eZone 0, IIC, T6\u003c\/span\u003e hazardous area\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetector Location:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eZone 0, IIC, T4-T6\u003c\/span\u003e with certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDivision Rating:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eDivision 1, Group A\u003c\/span\u003e hazardous location\u003c\/li\u003e\n\u003cli\u003eThe \u003cstrong\u003eMTL5015\u003c\/strong\u003e maintains intrinsic safety for both input channels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e7 to 9V\u003c\/span\u003e from 1kΩ ±10% source per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormal Phase:\u003c\/strong\u003e Output on if Iin \u0026gt;\u003cspan style=\"color: #2e75b6;\"\u003e2.1mA\u003c\/span\u003e or Rin \u0026lt;\u003cspan style=\"color: #2e75b6;\"\u003e2kΩ\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReverse Phase:\u003c\/strong\u003e Output off under same conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHysteresis:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e200µA typical\u003c\/span\u003e per channel for stable switching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Reversal:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eIndependent for each channel\u003c\/span\u003e, user-selectable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Frequency:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eDC to 5kHz\u003c\/span\u003e per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Off-state Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e35V\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-state Leakage:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e10µA maximum\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-state Voltage Drop:\u003c\/strong\u003e 1 + (0.13 x current in mA) V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum On-state Current:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e50mA\u003c\/span\u003e per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Floating outputs for logic circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eLine Fault Detection (LFD)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLFD Mode:\u003c\/strong\u003e User-selectable for each channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen-circuit Alarm:\u003c\/strong\u003e On if Iin \u0026lt;\u003cspan style=\"color: #2e75b6;\"\u003e50µA\u003c\/span\u003e, Off if Iin \u0026gt;\u003cspan style=\"color: #2e75b6;\"\u003e150µA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-circuit Alarm:\u003c\/strong\u003e On if Rin \u0026lt;\u003cspan style=\"color: #2e75b6;\"\u003e100Ω\u003c\/span\u003e, Off if Rin \u0026gt;\u003cspan style=\"color: #2e75b6;\"\u003e360Ω\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault Response:\u003c\/strong\u003e Detected line fault switches off the output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Input:\u003c\/strong\u003e Requires 500Ω-1kΩ series and 20kΩ-25kΩ parallel resistors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTerminal Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel 1 Input:\u003c\/strong\u003e Terminal 1 (Input –ve), Terminal 2 (Input +ve)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel 2 Input:\u003c\/strong\u003e Terminal 4 (Input –ve), Terminal 5 (Input +ve)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth Leakage:\u003c\/strong\u003e Terminal 3 (Ch 1), Terminal 6 (Ch 2) for detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel 1 Output:\u003c\/strong\u003e Terminal 10-11 (Output –ve), Terminal 12 (Output +ve)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel 2 Output:\u003c\/strong\u003e Terminal 8 (Output –ve), Terminal 9 (Output +ve)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Terminal 13 (Supply –ve), Terminal 14 (Supply +ve)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical \u0026amp; Power Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Weight:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e110g\u003c\/span\u003e compact and lightweight\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e44mA at 24V\u003c\/span\u003e maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e1.1W at 24V\u003c\/span\u003e maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Dissipation:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e1.6W at 35V\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e250V AC or DC\u003c\/span\u003e between circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSafety Parameters\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e10.5V\u003c\/span\u003e maximum per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Resistance:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e800Ω\u003c\/span\u003e per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Current:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e14mA\u003c\/span\u003e maximum per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eUm = 250V rms or DC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInter-channel Isolation:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e30V between hazardous-area circuits\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many outputs does the MTL5015 control?\u003c\/strong\u003e\u003cbr\u003eIt controls two independent solid-state outputs from two hazardous area inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the maximum operating frequency?\u003c\/strong\u003e\u003cbr\u003eIt operates from DC to 5kHz per channel for high-speed logic applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow does line fault detection work?\u003c\/strong\u003e\u003cbr\u003eIt detects open circuits (\u0026lt;50µA) and short circuits (\u0026lt;100Ω) with individual channel indication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the unit's weight?\u003c\/strong\u003e\u003cbr\u003eThe dual-channel interface weighs only 110 grams for easy installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor pricing and technical support, please contact \u003ca href=\"mailto:sale@etowonauto.com\"\u003esale@etowonauto.com\u003c\/a\u003e\u003c\/p\u003e","brand":"MTL","offers":[{"title":"Default Title","offer_id":51268337631364,"sku":"MTL5015","price":55.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/MTL5015.jpg?v=1762698716","url":"https:\/\/www.etowonauto.com\/pl\/products\/mtl5015-dual-solid-state-interface-mtl-instruments","provider":"Etowon Auto","version":"1.0","type":"link"}