{"product_id":"cc-kfpvr5-51202353-111-honeywell-16-ch-analog-input","title":"CC-KFPVR5 51202353-111 Honeywell 16-Ch Analog Input","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0066cc;\"\u003eCC-KFPVR5 51202353-111\u003c\/strong\u003e is a 16-channel analog input module from Honeywell, designed for high-level analog signal acquisition with HART communication. It accepts 0–10 V, ±10 V, or 4–20 mA inputs with 16-bit resolution and ±0.1% accuracy. Built for extreme environments, it operates from -40°C to 70°C. Weight: 2.0 kg.\u003c\/p\u003e\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003ch3\u003e16-Channel Analog Input with HART\u003c\/h3\u003e\n\u003cp\u003e16 single-ended inputs supporting voltage (0–10 V \/ ±10 V) and current (4–20 mA) signals. HART communication enables digital data overlay on analog loops for diagnostics and configuration. 1500 VDC channel-to-bus isolation ensures signal integrity.\u003c\/p\u003e\n\u003ch3\u003eHigh-Speed Scanning\u003c\/h3\u003e\n\u003cp\u003e250 ms update rate per channel delivers fast, accurate data acquisition. 16-bit resolution and ±0.1% accuracy provide precise measurement for critical process control.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eCC-KFPVR5 51202353-111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e16 single-ended inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eHigh-level analog with HART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e0–10 V or ±10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Range\u003c\/td\u003e\n\u003ctd\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;1 MΩ (voltage) \/ 250 Ω (current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e250 ms per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VDC channel-to-bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e12.1 cm x 2.5 cm x 11.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e12 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003ch3\u003eWiring\u003c\/h3\u003e\n\u003cp\u003eConnect voltage or current signals to the 16 single-ended inputs. For current loops, ensure 250 Ω load impedance. Use shielded twisted-pair cables to minimize noise. HART communication requires a compatible hand-held or host system.\u003c\/p\u003e\n\u003ch3\u003eConfiguration\u003c\/h3\u003e\n\u003cp\u003eConfigure input range (voltage\/current) and HART parameters via Honeywell DCS or configuration software. The module supports digital HART data extraction for device diagnostics and process variable monitoring.\u003c\/p\u003e\n\u003ch3\u003eMaintenance\u003c\/h3\u003e\n\u003cp\u003e1500 VDC isolation protects against ground loops and transients. Regular inspection of connections and LED status indicators ensures reliable operation. 12-month warranty provides coverage for manufacturing defects.\u003c\/p\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003ch3\u003eExtreme Temperature Operation\u003c\/h3\u003e\n\u003cp\u003eWide operating range of -40°C to 70°C enables deployment in outdoor, unheated, and process-intensive environments. Suitable for oil, gas, and chemical applications.\u003c\/p\u003e\n\u003ch3\u003eHART Communication\u003c\/h3\u003e\n\u003cp\u003eIntegrated HART capability allows digital access to field device diagnostics, calibration data, and secondary variables without additional wiring. Reduces maintenance costs and improves process insight.\u003c\/p\u003e\n\u003ch3\u003eHigh Accuracy \u0026amp; Speed\u003c\/h3\u003e\n\u003cp\u003e±0.1% accuracy with 16-bit resolution ensures precise measurement. 250 ms update rate per channel supports fast control loops and real-time monitoring.\u003c\/p\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e What input types does this module support?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e Voltage (0–10 V or ±10 V) and current (4–20 mA). Input impedance is \u0026gt;1 MΩ for voltage and 250 Ω for current.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e Does this module support HART communication?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e Yes. Each channel supports HART digital communication overlay on analog signals, enabling device diagnostics and configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e What is the isolation rating?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e 1500 VDC channel-to-bus isolation, protecting against ground loops and electrical transients.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52738035318916,"sku":"CC-KFPVR5","price":225.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-KFPVR5.jpg?v=1787987733","url":"https:\/\/www.etowonauto.com\/pl\/products\/cc-kfpvr5-51202353-111-honeywell-16-ch-analog-input","provider":"Etowon Auto","version":"1.0","type":"link"}