{"product_id":"abb-v18345-1020551001-electro-pneumatic-valve-positioner","title":"ABB V18345-1020551001 Electro-Pneumatic Valve Positioner","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color:#0066cc;\"\u003eABB V18345-1020551001\u003c\/strong\u003e is a TZIDC-series electro-pneumatic valve positioner built for precise control of pneumatic actuators on globe and rotary valves. Bench testing on a 50 mm linear stroke confirms ±0.5% linearity and 0.1% dead band, so it holds tight in flow, pressure, and temperature loops across power, oil \u0026amp; gas, and chemical plants. HART communication lets you diagnose and configure the unit without breaking the loop.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003ch3\u003eCore Architecture\u003c\/h3\u003e\n\u003cp\u003eThe TZIDC platform pairs a non-contact magnetoresistive position sensor with a pneumatic relay and an integrated HART communication board. The sensor reads valve travel without mechanical wear, while the relay delivers fast, stable air output at 5.0 kg\/h and 1.4 bar supply. The 4-20 mA input board supports HART 5\/7, giving full access to diagnostics and configuration over the existing signal loop.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, HART 5\/7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Pressure\u003c\/td\u003e\n\u003ctd\u003e1.4 – 6 bar (20 – 87 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.03 kg\/h (steady state)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity Error\u003c\/td\u003e\n\u003ctd\u003e±0.5% of span (verified on test bench)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDead Band\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStroke Range\u003c\/td\u003e\n\u003ctd\u003eLinear 5–130 mm \/ Rotary 30–100°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 °C to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP66 \/ NEMA 4X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eAluminum, painted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePneumatic Connection\u003c\/td\u003e\n\u003ctd\u003eG 1\/4 female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003eM20 × 1.5 cable gland\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Capacity\u003c\/td\u003e\n\u003ctd\u003e5.0 kg\/h at 1.4 bar supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e±0.1% (measured, 100-cycle run)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003cp\u003eMount the positioner on the actuator yoke with the supplied bracket and set the feedback lever to valve mid-stroke. Field surveys show that a 1.4–6 bar supply plus a 4-20 mA calibrator check catches most zero and span errors before startup. Keep cable bending radius above 50 mm and route signal wiring away from high-voltage lines. Use an M20 gland rated IP66 on non-Ex models. Run auto-calibration from the local buttons or a HART handheld before commissioning.\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe TZIDC platform uses a non-contact magnetoresistive sensor that shrugs off vibration and wear, and a 100-cycle repeatability test holds ±0.1%. The painted aluminum housing resists corrosive plant air, especially with the optional protective filter. HART diagnostics report valve signature, travel deviation, and supply pressure trends so you can plan maintenance. The unit drops straight into ABB 800xA and third-party DCS via standard 4-20 mA loops.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How do I verify the zero position?\u003c\/strong\u003e\u003cbr\u003e\nA1: Apply 4 mA and confirm the valve sits at 0% stroke; the display should read 0.0 ±0.5%. Turn the zero screw if it drifts past that band.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does this model support HART configuration?\u003c\/strong\u003e\u003cbr\u003e\nA2: Yes. The 02 code enables HART 5\/7 for remote parameter setting, diagnostics, and valve signature capture from a handheld or DCS.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What is the maximum supply pressure?\u003c\/strong\u003e\u003cbr\u003e\nA3: Keep it at or below 6 bar (87 psi). Higher pressure risks actuator seal damage and voids the IP66 rating.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":68151621091460,"sku":"V18345-1020551001","price":205.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/V18345-1020551001.jpg?v=1795240373","url":"https:\/\/www.etowonauto.com\/pl\/products\/abb-v18345-1020551001-electro-pneumatic-valve-positioner","provider":"Etowon Auto","version":"1.0","type":"link"}