{"product_id":"5437-079-woodward-netcon-duplex-field-terminal-module","title":"5437-079 Woodward | NetCon Duplex Field Terminal Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #003366;\"\u003eWoodward 5437-079\u003c\/strong\u003e is a high-reliability NetCon Duplex Field Terminal Module (FTM) engineered for critical prime mover control within Woodward MicroNet Plus and NetCon control architectures. Designed to facilitate seamless interconnectivity between control electronics and field relay modules, this FTM features a \u003cstrong\u003e37-pin sub-D connector configuration\u003c\/strong\u003e for robust control signal transmission. The 5437-079 delivers dependable load rejection performance, helping maintain system stability and rapid response during sudden load shed events or dynamic operating shifts. Constructed to withstand harsh industrial and marine environments, it meets stringent military-grade shock specifications (US MIL-STD-810C) and Lloyd’s register vibration standards across operating temperatures from 0°C to 55°C.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable border=\"1\" style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #003366; color: white;\"\u003e\n      \u003cth style=\"padding: 8px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background-color: #f0f9ff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eProduct Part Number\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003e\u003cstrong\u003e5437-079\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eManufacturer \/ Product Series\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eWoodward \/ NetCon \u0026amp; MicroNet Plus Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f0f9ff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eModule Type\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eNetCon Duplex Field Terminal Module (FTM)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eConnector Configuration\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003e37-Pin Connector (Multi-Relay Control Interface)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f0f9ff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003ePrimary Application Target\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003ePrime Mover Control, DLE Fuel Control, Relay Interfacing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eShock Resistance Standard\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eUS MIL-STD-810C Certified\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f0f9ff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eVibration Resistance Standard\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eLloyd’s ENV2 Test Qualified\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003e0°C to +55°C (32°F to +131°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f0f9ff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eApproximate Shipping Weight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003e\u003cstrong\u003e0.45 kg (1.0 lbs)\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eConstruction \u0026amp; Design\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eRugged Industrial Modular Terminal Base\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eKey Hardware \u0026amp; Operational Features\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e37-Pin Field Relay Interfacing:\u003c\/strong\u003e Dedicated multi-pin connection interface simplifies wiring routes to external relay banks while ensuring signal integrity for accurate switching execution.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Transient Load Rejection:\u003c\/strong\u003e Optimized for rapid-response turbines and prime movers, maintaining control stability during full or partial load rejection events.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMilitary \u0026amp; Marine Grade Durability:\u003c\/strong\u003e Engineered to withstand harsh industrial vibration and shock profiles according to US MIL-STD-810C and Lloyd’s ENV2 specifications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular System Compatibility:\u003c\/strong\u003e Seamlessly integrates with Woodward MicroNet Plus and NetCon control architectures, supporting advanced software algorithms like Dry Low Emissions (DLE) and incipient surge detection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation \u0026amp; Field Wiring Guidelines\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e1. Module Mounting:\u003c\/strong\u003e Secure the 5437-079 FTM onto the cabinet DIN rail or mounting panel near the target I\/O expansion racks.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e2. Cable Attachment:\u003c\/strong\u003e Connect the 37-pin field interface cable from the NetCon\/MicroNet controller to the matching header on the FTM, tightening securing screws to prevent loosening under vibration.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e3. Relay Wiring:\u003c\/strong\u003e Wire field devices and relay coils directly to the labeled terminal blocks according to the system channel assignment schematic.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1: What is the main function of the Woodward 5437-079 module?\u003c\/strong\u003e\u003cbr\u003e\nA1: It acts as a Field Terminal Module (FTM) to connect NetCon\/MicroNet control systems to field relay devices via a 37-pin connector.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: What industrial shock and vibration standards does this module meet?\u003c\/strong\u003e\u003cbr\u003e\nA2: It is tested and certified to US MIL-STD-810C for shock and Lloyd’s ENV2 for vibration resistance.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What control applications commonly use the 5437-079 FTM?\u003c\/strong\u003e\u003cbr\u003e\nA3: It is primarily used in prime mover controls, turbine load rejection management, naval propulsion, and DLE fuel control systems.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":52665503940740,"sku":"5437-079","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/5437-079.jpg?v=1787399984","url":"https:\/\/www.etowonauto.com\/pl\/products\/5437-079-woodward-netcon-duplex-field-terminal-module","provider":"Etowon Auto","version":"1.0","type":"link"}